  Title Dosimetric impact of physics libraries for electronic brachytherapy Monte Carlo studies Type Journal Article
  Year 2025 Publication Medical Physics Abbreviated Journal Med. Phys.  
  Volume Issue Pages 13pp  
  Keywords  
  Abstract Background Low-energy x-ray beams used in electronic brachytherapy (eBT) present significant dosimetric challenges due to their high depth-dose gradients, the dependence of detector response on materials, and the lack of standardized dose-to-water references. These challenges have driven the need for Monte Carlo (MC) simulations to ensure accurate dosimetry. However, discrepancies in the physics models used by different MC systems have raised concerns about their dosimetric consistency, particularly in modeling bremsstrahlung interactions. Purpose To assess the dosimetric impact of using different physics approaches in three state-of-the-art MC systems for eBT, focusing on the disagreements observed when different MC methods are used to evaluate bremsstrahlung interactions. Methods The MC studies of the Axxent S700, the Esteya, and the INTRABEAM eBT systems were performed using two EGSnrc applications (egsbrachy and egskerma), TOPAS, and PENELOPE-2018 (PEN18). The fluence spectra and depth doses were compared for simplified x-ray tube models, which maintain the target mode (transmission or reflection), the target material and thickness, and the surface applicators' source-to-surface distance. An extra simulation was made to evaluate the utility of the simplified models as proxies in predicting the most important characteristics of an accurate applicator's simulation (detailed model of INTRABEAM's 30 mm surface applicator). The EGSnrc applications and PEN18 utilized their default bremsstrahlung angular emission approaches. TOPAS used two physics lists: g4em-livermore (TOPAS(liv)) and g4em-penelope (TOPAS(pen)). Results The most significant differences between MC codes were observed for the transmission target mode. The bremsstrahlung component of the fluence spectra differed by about 15% on average, comparing PEN18, EGSnrc applications, and TOPAS(liv), with PEN18's fluences consistently lower. EGSnrc and PEN18 agreed within 3% for their characteristic spectrum components. However, PEN18's characteristic lines overreached TOPAS(liv)'s by 40%. Those spectral characteristics generated depth dose differences, where PEN18, on average, scored 9% lower than EGSnrc and TOPAS(liv). Considering TOPAS(pen) in the transmission mode, PEN18's fluence spectrum presented a lower bremsstrahlung (5%) but a higher characteristic component (10%); these spectral differences compensated, generating depth dose differences within 1% average. In the reflection target mode, EGSnrc and PEN18 agreed within 4% for the bremsstrahlung and characteristic components of the fluence spectra. With TOPAS(pen) in the reflection mode, PEN18 presents 12% lower fluences in the bremsstrahlung component but 6% higher characteristic lines. This spectral behavior diminished the depth dose differences up to 3%. Conclusion This work found considerable disagreements between three state-of-the-art MC systems commonly used in medical applications when simulating bremsstrahlung in eBT. The differences arose when the bremsstrahlung angular distribution and the atomic relaxation processes in the target became relevant. More theoretical and experimental studies are necessary to evaluate the impact of these differences on related calculations.  
  Address [Valdes-Cortez, Christian] Hosp Reg Antofagasta, Nucl Med Dept, Antofagasta, Chile, Email: javier.vijande@uv.es  
  Corporate Author Thesis  
  Publisher Wiley Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0094-2405 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001432297300001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 6543  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva