|
Andricek, L. et al, Lacasta, C., Marinas, C., & Vos, M. (2011). Intrinsic resolutions of DEPFET detector prototypes measured at beam tests. Nucl. Instrum. Methods Phys. Res. A, 638(1), 24–32.
Abstract: The paper is based on the data of the 2009 DEPFET beam test at CERN SPS. The beam test used beams of pions and electrons with energies between 40 and 120 GeV, and the sensors tested were prototypes with thickness of 450 μm and pixel pitch between 20 and 32 μm. Intrinsic resolutions of the detectors are calculated by disentangling the contributions of measurement errors and multiple scattering in tracking residuals. Properties of the intrinsic resolution estimates and factors that influence them are discussed. For the DEPFET detectors in the beam test, the calculation yields intrinsic resolutions of approximate to 1 μm, with a typical accuracy of 0.1 μm. Bias scan, angle scan, and energy scan are used as example studies to show that the intrinsic resolutions are a useful tool in studies of detector properties. With sufficiently precise telescopes, detailed resolution maps can be constructed and used to study and optimize detector performance.
|
|
|
AGATA Collaboration(Soderstrom, P. A. et al), & Gadea, A. (2011). Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors. Nucl. Instrum. Methods Phys. Res. A, 638(1), 96–109.
Abstract: The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected gamma-ray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted gamma-ray. The gamma-ray tracking was used to determine the full energy of the gamma-rays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of <1 mm in the FVVHM of the interaction position resolution for the gamma-ray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a (30)5i beam at 64 MeV on a thin C-12 target. Pulse-shape analysis of the digitized detector waveforms and gamma-ray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the gamma-ray energy and on the energy, axial location and type of the first interaction point, are presented. The FVVHM of the interaction position resolution varies roughly linearly as a function of gamma-ray energy from 8.5 mm at 250 key to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the gamma-ray energy range from 1.5 to 4 MeV.
|
|
|
Domingo-Pardo, C., Goel, N., Engert, T., Gerl, J., Kojouharov, I., Schaffner, H., et al. (2011). A novel gamma-ray imaging method for the pulse-shape characterization of position sensitive semiconductor radiation detectors. Nucl. Instrum. Methods Phys. Res. A, 643(1), 79–88.
Abstract: A new technique for the pulse-shape characterization of gamma-ray position sensitive germanium detectors is presented. This method combines the pulse shape comparison scan (PSCS) principle with a gamma-ray imaging technique. The latter is provided by a supplementary, high performance, position sensitive gamma-ray scintillator detector. We describe the basic aspects of the method and we show measurements made for the study of pulse-shapes in a non-segmented planar HPGe detector. A preliminary application of the PSCS is carried out, although a more detailed investigation is being performed with highly segmented position sensitive detectors.
|
|
|
Carles, M., Lerche, C. W., Sanchez, F., Mora, F., & Benlloch, J. M. (2011). Position correction with depth of interaction information for a small animal PET system. Nucl. Instrum. Methods Phys. Res. A, 648, S176–S180.
Abstract: In this work we study the effects on the spatial resolution when depth of interaction (001) information is included in the parameterization of the line of response (LOR) for a small animal positron emission tomography (PET) system. One of the most important degrading factors for PET is the parallax error introduced in systems that do not provide DOI information of the recorded gamma-rays. Our group has designed a simple and inexpensive method for DOI determination in continuous scintillation crystals. This method is based, on one hand, in the correlation between the scintillation light distribution width in monolithic crystals and the DOI, and, on the other hand, on a small modification of the widely applied charge dividing circuits (CDR). In this work we present a new system calibration that includes the DOI information, and also the development of the correction equations that relates the LOR without and with DOI information. We report the results obtained for different measurements along the transaxial field of view (FOV) and the image quality enhancement achieved specially at the edge of the FOV.
|
|
|
Llosa, G., Barrio, J., Lacasta, C., Callier, S., Raux, L., & de La Taille, C. (2011). First tests in the application of silicon photomultiplier arrays to dose monitoring in hadron therapy. Nucl. Instrum. Methods Phys. Res. A, 648, S96–S99.
Abstract: A detector head composed of a continuous LaBr3 crystal coupled to a silicon photomultiplier array has been mounted and tested, for its use in a Compton telescope for dose monitoring in hadron therapy. The LaBr3 crystal has 16 mm x 18 mm x 5 mm size, and it is surrounded with reflecting material in five faces. The SiPM array has 16 (4 x 4) elements of 3 mm x 3 mm size. The SPIROC1 ASIC has been employed as readout electronics. The detector shows a linear behavior up to 1275 keV. The energy resolution obtained at 511 keV is 7% FWHM, and it varies as one over the square root of the energy up to the energies tested. The variations among the detector channels are within 12%. A preliminary measurement of the timing resolution gives 7 ns FWHM. The spatial resolution obtained with the center of gravity method is 1.2 mm FWHM. The tests performed confirm the correct functioning of the detector.
|
|