|   | 
Details
   web
Records
Author XENON100 Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title (down) Observation and applications of single-electron charge signals in the XENON100 experiment Type Journal Article
Year 2014 Publication Journal of Physics G Abbreviated Journal J. Phys. G
Volume 41 Issue 3 Pages 035201 - 13pp
Keywords xenon; single electron; photoionization; double phase TPC
Abstract The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
Address [Aprile, E.; Budnik, R.; Choi, B.; Contreras, H.; Giboni, K-L; Goetzke, L. W.; Lim, K. E.; Fernandez, A. J. Melgarejo; Messina, M.; Plante, G.; Rizzo, A.] Columbia Univ, Dept Phys, New York, NY 10027 USA, Email: jacob.lamblin@lpsc.in2p3.fr;
Corporate Author Thesis
Publisher Iop Publishing Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0954-3899 ISBN Medium
Area Expedition Conference
Notes WOS:000331865800012 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 1959
Permanent link to this record
 

 
Author Cappuzzello, F.; Rea, C.; Bonaccorso, A.; Bondi, M.; Carbone, D.; Cavallaro, M.; Cunsolo, A.; Foti, A.; Orrigo, S.E.A.; Rodrigues, M.R.D.; Taranto, G.
Title (down) New structures in the continuum of C-15 populated by two-neutron transfer Type Journal Article
Year 2012 Publication Physics Letters B Abbreviated Journal Phys. Lett. B
Volume 711 Issue 5 Pages 347-352
Keywords Transfer reactions; States of C-15; Two-neutron break-up
Abstract The C-13(O-18,O-16)C-15 reaction has been studied at 84 MeV incident energy. The ejectiles have been detected at forward angles and C-15 excitation energy spectra have been obtained up to about 20 MeV. Several known bound and resonant states of C-15 have been identified together with two unknown structures at 10.5 MeV (FWHM = 2.5 MeV) and 13.6 MeV (FWHM = 2.5 MeV). Calculations based Oil the removal of two uncorrelated neutrons from the projectile describe a significant part of the continuum observed in the energy spectra. In particular the structure at 10.5 MeV is dominated by a resonance of C-15 near the C-13 + n + n threshold. Similar structures are found in nearby nuclei such as C-14 and Be-11.
Address [Cappuzzello, F.; Bondi, M.; Carbone, D.; Foti, A.; Taranto, G.] Univ Catania, Dipartimento Fis & Astron, I-95125 Catania, Italy, Email: cappuzzello@lns.infn.it
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0370-2693 ISBN Medium
Area Expedition Conference
Notes WOS:000304236500002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 1033
Permanent link to this record
 

 
Author Blank, B. et al; Agramunt, J.; Algora, A.; Guadilla, V.; Montaner-Piza, A.; Morales, A.I.; Orrigo, S.E.A.; Rubio, B.
Title (down) New neutron-deficient isotopes from Kr-78 fragmentation Type Journal Article
Year 2016 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 93 Issue 6 Pages 061301 - 5pp
Keywords
Abstract In an experiment with the RIKEN projectile fragment separator called BigRIPS at the RIKEN Nishina Center, the fragmentation of a Kr-78 beam allowed the observation of new neutron-deficient isotopes at the proton drip line. Clean identification spectra could be produced and Se-63, Kr-67, and Kr-68 were identified for the first time. In addition, Ge-59 was also observed. Three of these isotopes, Ge-59, Se-63, and Kr-67, are potential candidates for ground-state two-proton radioactivity. In addition, the isotopes Ge-58, Se-62, and Kr-66 were also sought but without success. The present experiment also allowed the determination of production cross sections for some of the most exotic isotopes. These measurements confirm the trend already observed that the empirical parametrization of fragmentation cross sections, EPAX, significantly overestimates experimental cross sections in this mass region.
Address [Blank, B.; Goigoux, T.; Ascher, P.; Gerbaux, M.; Giovinazzo, J.; Grevy, S.; Nieto, T. Kurtukian; Magron, C.] Univ Bordeaux, Ctr Etud Nucl Bordeaux Gradignan, UMR CNRS 5797, IN2P3, 19 Chemin Solarium,CS 10120, F-33175 Gradignan, France
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:000376997700001 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 2701
Permanent link to this record
 

 
Author XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title (down) Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment Type Journal Article
Year 2015 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 75 Issue 11 Pages 546 - 10pp
Keywords
Abstract The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Address [XENON Collaboration] Lab Nazl Gran Sasso, Assergi, Italy, Email: lbaudis@uzh.ch;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000365528200001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2477
Permanent link to this record
 

 
Author XENON100 Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title (down) Low-mass dark matter search using ionization signals in XENON100 Type Journal Article
Year 2016 Publication Physical Review D Abbreviated Journal Phys. Rev. D
Volume 94 Issue 9 Pages 092001 - 6pp
Keywords
Abstract We perform a low-mass dark matter search using an exposure of 30 kg x yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7 keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7 keV to 9.1 keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6 GeV/c(2) above 1.4 x 10(-41) cm(2) at 90% confidence level.
Address [Aprile, E.; Anthony, M.; de Perio, P.; Goetzke, L. W.; Greene, Z.; Fernandez, A. J. Melgarejo; Messina, M.; Plante, G.; Rizzo, A.; Weber, M.; Zhang, Y.] Columbia Univ, Dept Phys, New York, NY 10027 USA, Email: ran.budnik@weizmann.ac.il;
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2470-0010 ISBN Medium
Area Expedition Conference
Notes WOS:000386772500001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2845
Permanent link to this record