Fujita, Y., Rubio, B., Adachi, T., Blank, B., Fujita, H., Gelletly, W., et al. (2015). Gamow-Teller excitations studied by weak and strong interactions. Acta Phys. Pol. B, 46(3), 657–668.
Abstract: Studying weak nuclear responses, especially the Gamow-Teller (GT) transitions starting from stable as well as unstable nuclei, provide crucial and critical information on nuclear structure. Therefore, the study of GT transitions is a key issue in nuclear physics and also nuclear-astrophysics. Under the assumption of isospin symmetry, it is expected that the structure of mirror nuclei and the GT transitions starting from their ground states are identical. We have studied the corresponding GT transitions starting from T-z = +/- 1 and +/- 2 p f -shell nuclei, respectively, by means of hadronic (He-3,t) charge-exchange reactions and mirror beta decays. The results on GT strength distributions measured in beta decays and (He-3,t) reactions performed at an intermediate incident energy of 140 MeV/nucleon and 0 degrees are compared. The combined results help provide an understanding of nuclear structure of nuclei far-from-stability.
|
|
|
XENON Collaboration(Aprile, E. et al), & Orrigo, S. E. A. (2015). Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment. Eur. Phys. J. C, 75(11), 546–10pp.
Abstract: The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
|
|
|
XENON Collaboration(Aprile, E. et al), & Orrigo, S. E. A. (2017). Online Rn-222 removal by cryogenic distillation in the XENON100 experiment. Eur. Phys. J. C, 77(6), 358–8pp.
Abstract: We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant Rn-222 background originating from radon emanation. After inserting an auxiliary 222Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the Rn-222 activity concentration inside the XENON100 detector.
|
|
|
Cappuzzello, F., Rea, C., Bonaccorso, A., Bondi, M., Carbone, D., Cavallaro, M., et al. (2012). New structures in the continuum of C-15 populated by two-neutron transfer. Phys. Lett. B, 711(5), 347–352.
Abstract: The C-13(O-18,O-16)C-15 reaction has been studied at 84 MeV incident energy. The ejectiles have been detected at forward angles and C-15 excitation energy spectra have been obtained up to about 20 MeV. Several known bound and resonant states of C-15 have been identified together with two unknown structures at 10.5 MeV (FWHM = 2.5 MeV) and 13.6 MeV (FWHM = 2.5 MeV). Calculations based Oil the removal of two uncorrelated neutrons from the projectile describe a significant part of the continuum observed in the energy spectra. In particular the structure at 10.5 MeV is dominated by a resonance of C-15 near the C-13 + n + n threshold. Similar structures are found in nearby nuclei such as C-14 and Be-11.
|
|
|
XENON Collaboration(Aprile, E. et al), & Orrigo, S. E. A. (2017). Removing krypton from xenon by cryogenic distillation to the ppq level. Eur. Phys. J. C, 77(5), 275–12pp.
Abstract: The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the beta-emitter Kr-85 which is present in the xenon. For XENON1T a concentration of natural krypton in xenon Kr-nat/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10(-15) mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 . 10(5) with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of natKr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
|
|