Domingo-Pardo, C. (2016). Beta-delayed neutron emission: first measurements in the heavy mass region and future prospects. Acta Phys. Pol. B, 47(3), 729–737.
Abstract: Beta-delayed neutrons play a key role in the formation of heavy elements in explosive stellar environments. The final r-process abundance distribution, including the rare-earth peak, is tailored to a large extent by the neutrons released after the beta decay of very exotic neutron-rich nuclei encountered along the r-process path and during the freeze-out phase. Such scenarios involve a vast amount of – yet undiscovered – nuclei, and most of them are expected to be neutron emitters. In this respect, existing beta-delayed neutron emission data is rather scarce, spanning from the lightest isotopes up to the region of the fission-fragments with masses up to A similar to 150. This contribution gives an overview on the latest measurements of neutron branching ratios in the heavy mass region around N = 126, which was practically unexplored in the past. Present plans to access very exotic nuclei at the RIB-facility of RIKEN in the framework of the BRIKEN project, are presented, together with the expected impact in r-process nucleosynthesis studies.
|
|
|
Domingo-Pardo, C. (2016). i-TED: A novel concept for high-sensitivity (n,gamma) cross-section measurements. Nucl. Instrum. Methods Phys. Res. A, 825, 78–86.
Abstract: A new method for measuring (n, gamma) cross-sections aiming at enhanced signal-to-background ratio is presented. This new approach is based on the combination of the pulse-height weighting technique with a total energy detection system that features gamma-ray imaging capability (i-TED). The latter allows one to exploit Compton imaging techniques to discriminate between true capture gamma-rays arising from the sample under study and background gamma-rays coming from contaminant neutron (prompt or delayed) captures in the surrounding environment. A general proof-of-concept detection system for this application is presented in this paper together with a description of the imaging method and a conceptual demonstration based on Monte Carlo simulations.
|
|
|
Domingo-Pardo, C., Goel, N., Engert, T., Gerl, J., Kojouharov, I., Schaffner, H., et al. (2011). A novel gamma-ray imaging method for the pulse-shape characterization of position sensitive semiconductor radiation detectors. Nucl. Instrum. Methods Phys. Res. A, 643(1), 79–88.
Abstract: A new technique for the pulse-shape characterization of gamma-ray position sensitive germanium detectors is presented. This method combines the pulse shape comparison scan (PSCS) principle with a gamma-ray imaging technique. The latter is provided by a supplementary, high performance, position sensitive gamma-ray scintillator detector. We describe the basic aspects of the method and we show measurements made for the study of pulse-shapes in a non-segmented planar HPGe detector. A preliminary application of the PSCS is carried out, although a more detailed investigation is being performed with highly segmented position sensitive detectors.
|
|
|
Dudouet, J. et al, Domingo-Pardo, C., Gadea, A., & Perez-Vidal, R. M. (2017). Kr-96(36)60-Low-Z Boundary of the Island of Deformation at N=60. Phys. Rev. Lett., 118(16), 162501–6pp.
Abstract: Prompt.-ray spectroscopy of the neutron-rich Kr-96, produced in transfer-and fusion-induced fission reactions, has been performed using the combination of the Advanced Gamma Tracking Array and the VAMOS + +spectrometer. A second excited state, assigned to J pi = 4(+), is observed for the first time, and a previously reported level energy of the first 2+ excited state is confirmed. The measured energy ratio R-4/2 = E(4(+))/E(2(+)) = 2.12(1) indicates that this nucleus does not show a well-developed collectivity contrary to that seen in heavier N = 60 isotones. This new measurement highlights an abrupt transition of the degree of collectivity as a function of the proton number at Z = 36, of similar amplitude to that observed at N = 60 at higher Z values. A possible reason for this abrupt transition could be related to the insufficient proton excitations in the g(9/2), d(5/2), and s(1/2) orbitals to generate strong quadrupole correlations or to the coexistence of competing different shapes. An unexpected continuous decrease of R-4/2 as a function of the neutron number up to N = 60 is also evidenced. This measurement establishes the Kr isotopic chain as the low-Z boundary of the island of deformation for N = 60 isotones. A comparison with available theoretical predictions using different beyond mean-field approaches shows that these models fail to reproduce the abrupt transitions at N = 60 and Z = 36.
|
|
|
Esposito, R. et al, & Domingo-Pardo, C. (2021). Design of the third-generation lead-based neutron spallation target for the neutron time-of-flight facility at CERN. Phys. Rev. Accel. Beams, 24(9), 093001–17pp.
Abstract: The neutron time-of-flight (n_TOF) facility at the European Laboratory for Particle Physics (CERN) is a pulsed white-spectrum neutron spallation source producing neutrons for two experimental areas: the Experimental Area 1 (EAR1), located 185 m horizontally from the target, and the Experimental Area 2 (EAR2), located 20 m above the target. The target, based on pure lead, is impacted by a high-intensity 20-GeV/c pulsed proton beam. The facility was conceived to study neutron-nucleus interactions for neutron kinetic energies between a few meV to several GeV, with applications of interest for nuclear astrophysics, nuclear technology, and medical research. After the second-generation target reached the end of its lifetime, the facility underwent a major upgrade during CERN's Long Shutdown 2 (LS2, 2019-2021), which included the installation of the new third-generation neutron target. The first- and second-generation targets were based on water-cooled massive lead blocks and were designed focusing on EAR1, since EAR2 was built later. The new target is cooled by nitrogen gas to avoid erosion-corrosion and contamination of cooling water with radioactive lead spallation products. Moreover, the new design is optimized also for the vertical flight path and EAR2. This paper presents an overview of the target design focused on both physics and thermomechanical performance, and includes a description of the nitrogen cooling circuit and radiation protection studies.
|
|