|   | 
Details
   web
Records
Author (up) Vitez-Sveiczer, A. et al; Algora, A.; Morales, A.I.; Rubio, B.; Agramunt, J.; Guadilla, V.; Montaner-Piza, A.; Orrigo, S.E.A.
Title The beta-decay of Kr-70 into Br-70: Restoration of the pseudo-SU(4) symmetry Type Journal Article
Year 2022 Publication Physics Letters B Abbreviated Journal Phys. Lett. B
Volume 830 Issue Pages 137123 - 8pp
Keywords Beta decay of Kr-70; pn pairing; GT strength distribution; Pseudo-SU(4) symmetry; QRPA calculations
Abstract The beta-decay of the even-even nucleus Kr-70 with Z=N+2, has been investigated at the Radioactive Ion Beam Factory (RIBF) of the RIKEN Nishina Center using the BigRIPS fragment separator, the ZeroDegree Spectrometer, the WAS3ABI implantation station and the EURICA HPGe cluster array. Fifteen gamma-rays associated with the beta-decay of( 70)Kr into Br-70 have been identified for the first time, defining ten populated states below E-exc=3300 keV. The half-life of Kr-70 was derived with increased precision and found to be t(1/2)=45.19 +/- 0.14 ms. The beta-delayed proton emission probability has also been determined as epsilon(p)=0.545(23)%. An increase in the beta-strength to the yrast 1(+) state in comparison with the heaviest Z=N+2 system studied so far (Ge-62 decay) is observed that may indicate increased np correlations in the T=0 channel. The beta-decay strength deduced from the results is interpreted in terms of the proton-neutron quasiparticle random-phase approximation (pnQRPA) and also with a schematic model that includes isoscalar and isovector pairing in addition to quadrupole deformation. The application of this last model indicates an approximate realization of pseudo-SU(4) symmetry in this system.
Address [Vitez-Sveiczer, A.; Algora, A.; Morales, A., I; Rubio, B.; Agramunt, J.; Guadilla, V; Montaner-Piza, A.; Orrigo, S. E. A.; Gelletly, W.] Univ Valencia, Inst Fis Corpuscular, CSIC, E-46071 Valencia, Spain, Email: algora@ific.uv.es;
Corporate Author Thesis
Publisher Elsevier Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0370-2693 ISBN Medium
Area Expedition Conference
Notes WOS:000832707200002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5316
Permanent link to this record
 

 
Author (up) Wu, J. et al; Algora, A.; Agramunt, J.; Morales, A.I.; Orrigo, S.E.A.; Tain, J.L.; Tarifeño-Saldivia, A.; Tolosa-Delgado, A.
Title First observation of isomeric states in 111Zr, 113Nb, and 115Mo Type Journal Article
Year 2022 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 106 Issue 6 Pages 064328 - 5pp
Keywords
Abstract Isomeric states in the neutron-rich nuclei 111Zr [T1/2 = 0.10(7) μs], 113Nb [T1/2 = 0.7(4) μs], 115Mo [T1/2 = 46(3) μs] were first identified at the Radioactive Ion Beam Factory (RIBF) of RIKEN by using in-flight fission and fragmentation of a 238U beam at an energy of 345 MeV/u. This is a brief report of the gamma transitions de -exciting from isomeric states and half-lives measurements, which provides the first spectroscopy in the nuclear region of prolate-to-oblate shape-phase transition around mass A approximate to 110.
Address [Wu, J.] Brookhaven Natl Lab, Natl Nucl Data Ctr, Upton, NY 11973 USA, Email: jwu2@bnl.gov
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:000906391600002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5452
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Removing krypton from xenon by cryogenic distillation to the ppq level Type Journal Article
Year 2017 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 77 Issue 5 Pages 275 - 12pp
Keywords
Abstract The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the beta-emitter Kr-85 which is present in the xenon. For XENON1T a concentration of natural krypton in xenon Kr-nat/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10(-15) mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 . 10(5) with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of natKr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
Address [Lin, Q.] Lab Nazl Gran Sasso, Assergi, Italy, Email: michaelmurra@wwu.de;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000400642800003 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 3114
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Online Rn-222 removal by cryogenic distillation in the XENON100 experiment Type Journal Article
Year 2017 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 77 Issue 6 Pages 358 - 8pp
Keywords
Abstract We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant Rn-222 background originating from radon emanation. After inserting an auxiliary 222Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the Rn-222 activity concentration inside the XENON100 detector.
Address [Aprile, E.; Anthony, M.; de Perio, P.; Gao, F.; Goetzke, L. W.; Greene, Z.; Lin, Q.; Messina, M.; Plante, G.; Rizzo, A.; Zhang, Y.] Columbia Univ, Dept Phys, 538 W 120th St, New York, NY 10027 USA, Email: stefan.bruenner@mpi-hd.mpg.de;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000402676000001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 3166
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Search for two-neutrino double electron capture of Xe-124 with XENON100 Type Journal Article
Year 2017 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 95 Issue 2 Pages 024605 - 6pp
Keywords
Abstract Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For Xe-124 this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K shell of 124Xe using 7636 kg d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90% credibility limit on the half-life T-1/2 > 6.5 x 10(20) yr. We have also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and found a sensitivity of T-1/2 > 6.1 x 10(22) yr after an exposure of 2 t yr.
Address [Agostini, F.; Barrow, P.; Berger, T.; Butikofer, L.; Cardoso, J. M. R.; Di Gangi, P.; Diglio, S.; Franco, D.; Garbini, M.; Grignon, C.; Kaminsky, B.; Le Calloch, M.; Lopes, J. A. M.; Orrigo, S. E. A.; Sartorelli, G.; Schreiner, J.; Thers, D.; Zhang, Y.] Columbia Univ, Dept Phys, 538 W 120th St, New York, NY 10027 USA, Email: a.fieguth@uni-muenster.de;
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:000393744200001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2956
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Results from a calibration of XENON100 using a source of dissolved radon-220 Type Journal Article
Year 2017 Publication Physical Review D Abbreviated Journal Phys. Rev. D
Volume 95 Issue 7 Pages 072008 - 10pp
Keywords
Abstract A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220-Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t(1/2) = (293.9 +/- (1.0)(stat) +/- (0.6)(sys)) ns.
Address [Aprile, E.; Anthony, M.; de Perio, P.; Gao, F.; Goetzke, L. W.; Greene, Z.; Lin, Q.; Messina, M.; Plante, G.; Rizzo, A.; Zhang, Y.] Columbia Univ, Dept Phys, New York, NY USA, Email: rafael@purdue.edu
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2470-0010 ISBN Medium
Area Expedition Conference
Notes WOS:000399945500001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 3101
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Physics reach of the XENON1T dark matter experiment Type Journal Article
Year 2016 Publication Journal of Cosmology and Astroparticle Physics Abbreviated Journal J. Cosmol. Astropart. Phys.
Volume 04 Issue 4 Pages 027 - 37pp
Keywords dark matter simulations; dark matter experiments
Abstract The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80+/-0.15) . 10(-4) (kg.day.keV)(-1), mainly due to the decay of Rn-222 daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 +/- 0.1) (t.y)(-1) from radiogenic neutrons, (1.8+/-0.3) . 10(-2) (t.y)(-1) from coherent scattering of neutrinos, and less than 0.01 (t.y)(-1) from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Pro file Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency L-eff, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 tonne fiducial volume, the sensitivity reaches a minimum cross section of 1.6 . 10(-47) cm(2) at m(chi) = 50 GeV/c(2).
Address [Aprile, E.; Anthony, M.; Contreras, H.; de Perio, P.; Goetzke, L. W.; Greene, Z.; Fernandez, A. J. Melgarejo; Messina, M.; Plante, G.; Rizzo, A.; Weber, M.; Zhang, Y.] Columbia Univ, Dept Phys, 538 W 120th St, New York, NY 10027 USA, Email: cyril.grignon@uni-mainz.de;
Corporate Author Thesis
Publisher Iop Publishing Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1475-7516 ISBN Medium
Area Expedition Conference
Notes WOS:000393286400005 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2950
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment Type Journal Article
Year 2015 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 75 Issue 11 Pages 546 - 10pp
Keywords
Abstract The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Address [XENON Collaboration] Lab Nazl Gran Sasso, Assergi, Italy, Email: lbaudis@uzh.ch;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000365528200001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2477
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Search for Event Rate Modulation in XENON100 Electronic Recoil Data Type Journal Article
Year 2015 Publication Physical Review Letters Abbreviated Journal Phys. Rev. Lett.
Volume 115 Issue 9 Pages 091302 - 6pp
Keywords
Abstract We have searched for periodic variations of the electronic recoil event rate in the (2-6) keVenergy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an unbinned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods, suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of weakly interacting massive particles to electrons is excluded at 4.8 sigma.
Address [Aprile, E.; Anthony, M.; Contreras, H.; de Perio, P.; Goetzke, L. W.; Fernandez, A. J. Melgarejo; Messina, M.; Plante, G.; Rizzo, A.; Weber, M.; Zhang, Y.] Columbia Univ, Dept Phys, New York, NY 10027 USA, Email: feigao.ge@sjtu.edu.cn;
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0031-9007 ISBN Medium
Area Expedition Conference
Notes WOS:000360289000004 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2399
Permanent link to this record
 

 
Author (up) XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A.
Title Exclusion of leptophilic dark matter models using XENON100 electronic recoil data Type Journal Article
Year 2015 Publication Science Abbreviated Journal Science
Volume 349 Issue 6250 Pages 851-854
Keywords
Abstract Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross sections above 6 x 10(-35) cm(2) for particle masses of m(chi) = 2 GeV/c(2). Independent of the dark matter halo, we exclude leptophilic models as an explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
Address
Corporate Author Thesis
Publisher Amer Assoc Advancement Science Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0036-8075 ISBN Medium
Area Expedition Conference
Notes WOS:000359832700045 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 2490
Permanent link to this record