Dias, J. M., Toledo, G., Roca, L., & Oset, E. (2021). Unveiling the K-1(1270) double-pole structure in the (B)over-bar -> J/psi rho(K)over-bar and (B)over-bar -> J/psi(K)over-bar*pi decays. Phys. Rev. D, 103(11), 116019–13pp.
Abstract: By looking at the pseudoscalar-vector meson spectra in the (B) over bar -> J/psi rho(K) over bar and (B) over bar -> J/psi(K) over bar*pi weak decays, we theoretically investigate the double-pole structure of the K-1 (1270) resonance by using the chiral unitary approach to account for the final-state interactions between the pseudoscalar (P) and vector (V) mesons. The K-1 (1270) resonance is dynamically generated through these interactions in coupled channels and influences the shape of the invariant mass distributions under consideration. We show how these shapes are affected by the K-1 (1270) double-pole structure to confront the results from our model with future experiments that might investigate the PV spectra in these decays.
|
Timar, J. et al, & Algora, A. (2019). Experimental Evidence for Transverse Wobbling in Pd-105. Phys. Rev. Lett., 122(6), 062501–6pp.
Abstract: New rotational bands built on the nu(h(11/2)) configuration have been identified in Pd-105. Two bands built on this configuration show the characteristics of transverse wobbling: the Delta I = 1 transitions between them have a predominant E2 component and the wobbling energy decreases with increasing spin. The properties of the observed wobbling bands are in good agreement with theoretical results obtained using constrained triaxial covariant density functional theory and quantum particle rotor model calculations. This provides the first experimental evidence for transverse wobbling bands based on a one-neutron configuration, and also represents the first observation of wobbling motion in the A similar to 100 mass region.
|
Thisse, D. et al, Algora, A., & Guadilla, V. (2023). Study of N=50 gap evolution around Z=32: new structure information for Ge-82. Eur. Phys. J. A, 59(7), 153–13pp.
Abstract: Medium spin states of light N = 50 isotones have been populated using fast neutron-induced fission of Th-232. Online prompt gamma spectroscopy has been performed using the hybrid gamma spectrometer nu-Ball coupled to the LICORNE directional neutron source at the ALTO facility of IJCLab. Medium spin states of the neutron-rich nucleus Ge-82 have been investigated using gamma-gamma and gamma-gamma-gamma coincidence data to exploit the resolving power of nu-Ball. Two new transitions were assigned to this nucleus and a new level was placed in the level scheme. We tentatively assigned to this new state a (7(+)) spin-parity, which is interpreted as a new N = 50 core breaking state. This provides further insight into the energy evolution of the N = 50 shell gap toward Ni-78.
|
Testov, D. et al, & Gadea, A. (2019). The 4pi highly-efficient light-charged-particle detector EUCLIDES, installed at the GALILEO array for in-beam gamma-ray spectroscopy. Eur. Phys. J. A, 55(4), 47–8pp.
Abstract: .In a fusion-evaporation reaction, nuclei are produced by evaporating light-charged particles and neutrons from the compound nucleus. Typically, a nucleus of interest is produced as a result of a part of the total cross-section and, in order to guarantee a good channel discrimination, a particle detector, like the EUCLIDES 4 Si-ball array, is necessary. EUCLIDES has been quoted in more than a hundred publications resulting from many experiments performed in combination with the EUROBALL and GASP -ray spectrometers. The present paper reports on the upgraded version of EUCLIDES, that is presently coupled to the new GALILEO -ray spectrometer, installed at the Laboratori Nazionali di Legnaro, INFN. The design, characteristics and performance of the EUCLIDES array are presented and discussed.
|
Terol-Calvo, J., Tortola, M., & Vicente, A. (2020). High-energy constraints from low-energy neutrino nonstandard interactions. Phys. Rev. D, 101(9), 095010–14pp.
Abstract: Many scenarios of new physics predict the existence of neutrino nonstandard interactions, new vector contact interactions between neutrinos, and first generation fermions beyond the Standard Model. We obtain model-independent constraints on the Standard Model effective field theory at high energies from bounds on neutrino nonstandard interactions derived at low energies. Our analysis explores a large set of new physics scenarios and includes full one-loop running effects below and above the electroweak scale. Our results show that neutrino nonstandard interactions already push the scale of new physics beyond the TeV. We also conclude that bounds derived by other experimental probes, in particular by low-energy precision measurements and by charged lepton flavor violation searches, are generally more stringent. Our study constitutes a first step toward the systematization of phenomenological analyses to evaluate the impact of neutrino nonstandard interactions for new physics scenarios at high energies.
|
Ternes, C. A., Gariazzo, S., Hajjar, R., Mena, O., Sorel, M., & Tortola, M. (2019). Neutrino mass ordering at DUNE: An extra nu bonus. Phys. Rev. D, 100(9), 093004–10pp.
Abstract: We study the possibility of extracting the neutrino mass ordering at the future Deep Underground Neutrino Experiment using atmospheric neutrinos, which will be available before the muon neutrino beam starts being operational. The large statistics of the atmospheric muon neutrino and antineutrino samples at the far detector, together with the baselines of thousands of kilometers that these atmospheric (anti) neutrinos travel, provide ideal ingredients to extract the neutrino mass ordering via matter effects in the neutrino propagation through Earth. Crucially, muon capture by argon provides excellent charge tagging, allowing us to disentangle the neutrino and antineutrino signature. This is an important extra benefit of having a liquid argon time projection chamber as a far detector, that could render an similar to 3.5 sigma extraction of the mass ordering after approximately 7 yr of exposure.
|
n_TOF Collaboration(Tarrío, D. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2023). Neutron-induced fission cross sections of Th-232 and U-233 up to 1 GeV using parallel plate avalanche counters at the CERN n_TOF facility. Phys. Rev. C, 107(4), 044616–21pp.
Abstract: The neutron-induced fission cross sections of Th-232 and U-233 were measured relative to U-235 in a wide neutron energy range up to 1 GeV (and from fission threshold in the case of Th-232, and from 0.7 eV in case of U-233), using the white-spectrum neutron source at the CERN Neutron Time-of-Flight (nTOF) facility. Parallel plate avalanche counters (PPACs) were used, installed at the Experimental Area 1 (EAR1), which is located at 185 m from the neutron spallation target. The anisotropic emission of fission fragments were taken into account in the detection efficiency by using, in the case of U-233, previous results available in EXFOR, whereas in the case of Th-232 these data were obtained from our measurement, using PPACs and targets tilted 45 degrees with respect to the neutron beam direction. Finally, the obtained results are compared with past measurements and major evaluated nuclear data libraries. Calculations using the high-energy reaction models INCL++ and ABLA07 were performed and some of their parameters were modified to reproduce the experimental results. At high energies, where no other neutron data exist, our results are compared with experimental data on proton-induced fission. Moreover, the dependence of the fission cross section at 1 GeV with the fissility parameter of the target nucleus is studied by combining those ( p, f) data with our (n, f) data on Th-232 and U-233 and on other isotopes studied earlier at nTOF using the same experimental setup.
|
Tarifeño-Saldivia, A., Calvino, F., De Blas, A., Brusasco, B., Casanovas-Hoste, A., Cives, A. M., et al. (2024). Ambient dosimetry in pulsed neutron fields with LINrem detectors. Radiat. Phys. Chem., 224, 112101–7pp.
Abstract: The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fields generated by fusion plasmas and high-intensity pulsed lasers are presented. Additionally, prospects and future plans for the LINrem project are outlined.
|
Tarifeño-Saldivia, A., & Soto, L. (2014). Effects of gas chamber geometry and gas flow on the neutron production in a fast plasma focus neutron source. Plasma Phys. Control. Fusion, 56(12), 125013–5pp.
Abstract: This work reports that gas chamber geometry and gas flow management substantially affect the neutron production of a repetitive fast plasma focus. The gas flow rate is the most sensitive parameter. An appropriate design of the gas chamber combined with a suitable flow-rate management can lead to improvements in the neutron production of one order of magnitude working in a fast repetitive mode.
|
BRIKEN Collaboration(Tarifeño-Saldivia, A. et al), Tain, J. L., Domingo-Pardo, C., Agramunt, J., Algora, A., Morales, A. I., et al. (2017). Conceptual design of a hybrid neutron-gamma detector for study of beta-delayed neutrons at the RIB facility of RIKEN. J. Instrum., 12, P04006–22pp.
Abstract: BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, β-particles, γ-rays and β-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.
|