|
Alimena, J. et al, Hirsch, M., Mamuzic, J., Mitsou, V. A., & Santra, A. (2020). Searching for long-lived particles beyond the Standard Model at the Large Hadron Collider. J. Phys. G, 47(9), 090501–226pp.
Abstract: Particles beyond the Standard Model (SM) can generically have lifetimes that are long compared to SM particles at the weak scale. When produced at experiments such as the Large Hadron Collider (LHC) at CERN, these long-lived particles (LLPs) can decay far from the interaction vertex of the primary proton-proton collision. Such LLP signatures are distinct from those of promptly decaying particles that are targeted by the majority of searches for new physics at the LHC, often requiring customized techniques to identify, for example, significantly displaced decay vertices, tracks with atypical properties, and short track segments. Given their non-standard nature, a comprehensive overview of LLP signatures at the LHC is beneficial to ensure that possible avenues of the discovery of new physics are not overlooked. Here we report on the joint work of a community of theorists and experimentalists with the ATLAS, CMS, and LHCb experiments-as well as those working on dedicated experiments such as MoEDAL, milliQan, MATHUSLA, CODEX-b, and FASER-to survey the current state of LLP searches at the LHC, and to chart a path for the development of LLP searches into the future, both in the upcoming Run 3 and at the high-luminosity LHC. The work is organized around the current and future potential capabilities of LHC experiments to generally discover new LLPs, and takes a signature-based approach to surveying classes of models that give rise to LLPs rather than emphasizing any particular theory motivation. We develop a set of simplified models; assess the coverage of current searches; document known, often unexpected backgrounds; explore the capabilities of proposed detector upgrades; provide recommendations for the presentation of search results; and look towards the newest frontiers, namely high-multiplicity 'dark showers', highlighting opportunities for expanding the LHC reach for these signals.
|
|
BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2013). The BABAR detector: Upgrades, operation and performance. Nucl. Instrum. Methods Phys. Res. A, 729, 615–701.
Abstract: The BABAR detector operated successfully at the PEP-Il asymmetric e(+) e(-) collider at the SLAC National Accelerator Laboratory from 1999 to 2008. This report covers upgrades, operation, and performance of the collider and the detector systems, as well as the trigger, online and offline computing, and aspects of event reconstruction since the beginning of data taking.
|
|
BABAR Collaboration(Lees, J. P. et al), Martinez-Vidal, F., Oyanguren, A., & Villanueva-Perez, P. (2013). Time-integrated luminosity recorded by the BABAR detector at the PEP-II e(+)e(-) collider. Nucl. Instrum. Methods Phys. Res. A, 726, 203–213.
Abstract: We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e(+)e(-) collider at the Upsilon(4S), Upsilon(3S), and Upsilon(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e(+)e(-)-> e(+)e(-) and (for the Upsilon(4S) only) e(+)e(-)->mu(+)mu(-) candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e(+)e(-)-> e(+)e(-) and e(+)e(-)->mu(+)mu(-), the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the Upsilon(3S) and Upsilon(2S) resonances, an additional uncertainty arises due to Upsilon -> e(+)e(-)X background. For data collected off the Upsilon resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the Upsilon(4S), 0.58% (0.72%) for the Upsilon(3S), and 0.68% (0.88%) for the Upsilon(2S).
|
|
Belle II Collaboration(Abudinen, F. et al), Gomis, P., & Marinas, C. (2020). Measurement of the integrated luminosity of the Phase 2 data of the Belle II experiment. Chin. Phys. C, 44(2), 021001–12pp.
Abstract: From April to July 2018, a data sample at the peak energy of the resonance was collected with the Belle II detector at the SuperKEKB electron-positron collider. This is the first data sample of the Belle II experiment. Using Bhabha and digamma events, we measure the integrated luminosity of the data sample to be (, where the first uncertainty is statistical and the second is systematic. This work provides a basis for future luminosity measurements at Belle II.
|