|
Abdallah, J. et al, Cerda Alberich, L., Fiorini, L., Gomez Delegido, A. J., & Valero, A. (2025). Study of the radiation hardness of the ATLAS Tile Calorimeter optical instrumentation with Run 2 data. J. Instrum., 20(6), P06006–29pp.
Abstract: This paper presents a study of the radiation hardness of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2. Both the plastic scintillators constituting the detector active media and the wavelength-shifting optical fibres collecting the scintillation light into the photodetector readout are elements susceptible to radiation damage. The dedicated calibration and monitoring systems of the detector (caesium radioactive sources, laser and minimum bias integrator) allow to assess the response of these optical components. Data collected with these systems between 2015 and 2018 are analysed to measure the degradation of the optical instrumentation across Run 2. Moreover, a simulation of the total ionising dose in the calorimeter is employed to study and model the degradation profile as a function of the exposure conditions, both integrated dose and dose rate. The measurement of the relative light output loss in Run 2 is presented and extrapolations to future scenarios are drawn based on current data. The impact of radiation damage on the cell response uniformity is also analysed.
|
|
|
An, L., Auffray, E., Betti, F., Dall'Omo, F., Gascon, D., Golutvin, A., et al. (2023). Performance of a spaghetti calorimeter prototype with tungsten absorber and garnet crystal fibres. Nucl. Instrum. Methods Phys. Res. A, 1045, 167629–7pp.
Abstract: A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd3Al2Ga3O12 (GAGG:Ce) and Y3Al5O12 (YAG:Ce) embedded in a pure tungsten absorber. The energy resolution root was studied as a function of the incidence angle of the beam and found to be of the order of 10%/ E a 1%, in line with the LHCb Shashlik technology. The time resolution was measured with metal channel dynode photomultipliers placed in contact with the fibres or coupled via a light guide, additionally testing an optical tape to glue the components. Time resolution of a few tens of picosecond was achieved for all the energies reaching down to (18.5 +/- 0.2) ps at 5 GeV.
|
|
|
Azevedo, C. D. R., Baeza, A., Chauveau, E., Corbacho, J. A., Diaz, J., Domange, J., et al. (2023). Development of a real-time tritium-in-water monitor. J. Instrum., 18(12), T12008–14pp.
Abstract: In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a Minimum Detectable Activity (MDA) of 100 Bq/L of tritium-in-water activity which is the limit established by the E.U. Council Directive 2013/51/Euratom for water intended for human consumption. The same system can be used as a real-time pre-alert system for nuclear power plant regarding tritium-in water environmental surveillance. The first detector module was characterized, commissioned and installed immediately after the discharge channel of the Arrocampo dam (Almaraz nuclear power plant, Spain) on the Tagus river. Due to the high sensitivity of the single detection modules, the system requires radioactive background mitigation techniques through the use of active and passive shielding. We have extrapolated a MDA of 3.6 kBq/L for a single module being this value limited by the cosmic background. The obtained value for a single module is already compatible with a real-time environmental surveillance and pre-alert system. Further optimization of the single-module sensitivity will imply the reduction of the number of modules and the cost of the detector system.
|
|