|
Ahlburg, P. et al, & Marinas, C. (2020). EUDAQ – a data acquisition software framework for common beam telescopes. J. Instrum., 15(1), P01038–30pp.
Abstract: EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
|
|
|
Andricek, L. et al, Lacasta, C., Marinas, C., & Vos, M. (2011). Intrinsic resolutions of DEPFET detector prototypes measured at beam tests. Nucl. Instrum. Methods Phys. Res. A, 638(1), 24–32.
Abstract: The paper is based on the data of the 2009 DEPFET beam test at CERN SPS. The beam test used beams of pions and electrons with energies between 40 and 120 GeV, and the sensors tested were prototypes with thickness of 450 μm and pixel pitch between 20 and 32 μm. Intrinsic resolutions of the detectors are calculated by disentangling the contributions of measurement errors and multiple scattering in tracking residuals. Properties of the intrinsic resolution estimates and factors that influence them are discussed. For the DEPFET detectors in the beam test, the calculation yields intrinsic resolutions of approximate to 1 μm, with a typical accuracy of 0.1 μm. Bias scan, angle scan, and energy scan are used as example studies to show that the intrinsic resolutions are a useful tool in studies of detector properties. With sufficiently precise telescopes, detailed resolution maps can be constructed and used to study and optimize detector performance.
|
|
|
Andricek, L., Boronat, M., Fuster, J., Garcia, I., Gomis, P., Marinas, C., et al. (2016). Integrated cooling channels in position-sensitive silicon detectors. J. Instrum., 11, P06018–15pp.
Abstract: We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10 W/cm(2). The liquid flow is found to have a negligible impact on the mechanical stability. A finite-element simulation predicts the cooling performance to an accuracy of approximately 10%.
|
|
|
Babeluk, M. et al, & Marinas, C. (2023). CMOS MAPS upgrade for the Belle II Vertex Detector. Nucl. Instrum. Methods Phys. Res. A, 1048, 168015–5pp.
Abstract: The success of the Belle II experiment in Japan relies on the very high instantaneous luminosity, close to 6x1035 cm-2 s-1, expected from the SuperKEKB collider. The corresponding beam conditions at such luminosity levels generate large rates of background particles and creates stringent constraints on the vertex detector, adding to the physics requirements. Current prospects for the occupancy rates in the present vertex detector (VXD) at full luminosity fall close to the acceptable limits and bear large uncertainties. In this context, the Belle II collaboration is considering the possibility to install an upgraded VXD system around 2027 to provide a sufficient safety margin with respect to the expected background rate and possibly enhance tracking and vertexing performance. The VTX collaboration has started the design of a fully pixelated VXD, called VTX, based on fast and highly granular Depleted Monolithic Active Pixel Sensors (DMAPS) integrated on light support structures. The two main technical features of the VTX proposal are the usage of a single sensor type over all the layers of the system and the overall material budget below 2% of radiation length, compared to the current VXD which has two different sensor technologies and about 3% of radiation length. A dedicated sensor (OBELIX), taylored to the specific needs of Belle II, is under development, evolving from the existing TJ-Monopix2 sensor. The time-stamping precision below 100 ns will allow all VTX layers to take part in the track finding strategy contrary to the current situation. The first two detection layers are designed according to a self-supported all-silicon ladder concept, where 4 contiguous sensors are diced out of a wafer, thinned and interconnected with post-processed redistribution layers. The outermost detection layers follow a more conventional approach with a cold plate and carbon fibre support structure, and light flex cables interconnecting the sensors. This document will review the context, technical details and development status of the proposed Belle II VTX.
|
|
|
Belle II Collaboration(Abudinen, F. et al), Gomis, P., & Marinas, C. (2020). Measurement of the integrated luminosity of the Phase 2 data of the Belle II experiment. Chin. Phys. C, 44(2), 021001–12pp.
Abstract: From April to July 2018, a data sample at the peak energy of the resonance was collected with the Belle II detector at the SuperKEKB electron-positron collider. This is the first data sample of the Belle II experiment. Using Bhabha and digamma events, we measure the integrated luminosity of the data sample to be (, where the first uncertainty is statistical and the second is systematic. This work provides a basis for future luminosity measurements at Belle II.
|
|