LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Measurement of CP observables in B+/- -> DK+/- and B+/- -> D pi+/- with D -> KS0 K+/- pi-/+ decays. J. High Energy Phys., 06(6), 058–25pp.
Abstract: Measurements of CP observables in B-+/- -> DK +/- and B-+/- -> D pi (+/-) decays are presented, where D represents a superposition of D-0 and D<overbar>0 states. The D meson is reconstructed in the three-body final states KS0K +/- pi -/+ and KS0K -/+ pi +/-. The analysis uses samples of B mesons produced in proton-proton collisions, corresponding to an integrated luminosity of 1.0, 2.0, and 6.0 fb(-1) collected with the LHCb detector at centre-of-mass energies of <mml:msqrt>s</mml:msqrt> = 7, 8, and 13 TeV, respectively. These measurements are the most precise to date, and provide important input for the determination of the CKM angle gamma.
|
LHCb Collaboration(Aaij, R. et al), Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2021). Measurement of CP observables in B-+/- -> D-(*K-)(+/-) and B-+/- -> D-(*())pi(+/-) decays using two-body D final states. J. High Energy Phys., 04(4), 081–36pp.
Abstract: Measurements of CP observables in B-+/- -> D(*) K-+/- and B-+/- -> D(*) pi(+/-) decays are presented, where D(*) indicates a neutral D or D* meson that is an admixture of meson and anti-meson states. Decays of the D(*) meson to the D pi(0) and D gamma final states are partially reconstructed without inclusion of the neutral pion or photon. Decays of the D meson are reconstructed in the K-+/-pi(-/+), K+K-, and pi(+)pi(-) final states. The analysis uses a sample of charged B mesons produced in proton-proton collisions and collected with the LHCb experiment, corresponding to integrated luminosities of 2.0, 1.0, and 5.7 fb(-1) taken at centre-of-mass energies of 7, 8, and 13TeV, respectively. The measurements of partially reconstructed B-+/- -> D(*) K-+/- and B-+/- -> D(*)pi(+/-) with D -> K--/+pi(+/-) decays are the first of their kind, and a first observation of the B-+/- -> (D pi(0)) D*pi(+/-) decay is made with a significance of 6.1 standard deviations. All CP observables are measured with world-best precision, and in combination with other LHCb results will provide strong constraints on the CKM angle gamma.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2019). Measurement of CP observables in the process B-0 -> DK*0 with two- and four-body D decays. J. High Energy Phys., 08(8), 041–30pp.
Abstract: Measurements of CP observables in B-0 -> DK0 decays are presented, where D represents a superposition of D-0 and D0 states. The D meson is reconstructed in the two-body final states K+pi(-), pi K-+(-), K+K- and pi(+)pi(-), and, for the first time, in the fourbody final states K+pi(-)pi(+)pi(-), pi K-+(-)pi(+)pi(-) and pi(+)pi(-)pi(+)pi(-). The analysis uses a sample of neutral B mesons produced in proton-proton collisions, corresponding to an integrated luminosity of 1.0, 2.0 and 1.8 fb(-1) collected with the LHCb detector at centre-of-mass energies of ,8 and 13 TeV, respectively. First observations of the decays B-0 -> D(pi K-+(-))K-0 and B-0 -> D(pi(+)pi(-)pi(+)pi(-))K-0 are obtained. The measured observables are interpreted in terms of the CP -violating weak phase gamma.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Measurement of CP violation in B-0 -> (DD -/+)-D-*+/- decays. J. High Energy Phys., 03(3), 147–28pp.
Abstract: The decay-time-dependent CP asymmetry in B-0 -> (DD -/+)-D-*+/- decays is mea- sured using a data set corresponding to an integrated luminosity of 9 fb(-1) recorded by the LHCb detector in proton-proton collisions at centre-of-mass energies of 7, 8 and 13 TeV. The CP parameters are measured asSD*D=-0.861 +/- 0.077 +/- 0.019,Delta SD*D=0.019 +/- 0.075 +/- 0.012,CD*D=-0.059 +/- 0.092 +/- 0.020,Delta CD*D=-0.031 +/- 0.092 +/- 0.016,AD*D=0.008 +/- 0.014 +/- 0.006. The analysis provides the most precise single measurement of CP violation in this decay channel to date. All parameters are consistent with their current world average values.
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2024). Measurement of CP Violation in B0 → ψ(→ l+ l-)KS0(→ π+ π-) Decays. Phys. Rev. Lett., 132(2), 021801–12pp.
Abstract: A measurement of time-dependent CP violation in the decays of B-0 and (B) over bar (0) mesons to the final states J/psi(-> mu(+) mu(-))K-S(0), psi(2S)(-> mu(+) mu(-))K-S(0) and J/psi(-> e(+)e(-))K-S(0) with K-S(0) -> pi(+)pi(-) is presented. The data correspond to an integrated luminosity of 6 fb(-1) collected at a center-of-mass energy of root s = 13 TeV with the LHCb detector. The CP-violation parameters are measured to be S-psi KS0 = 0.717 +/- 0.013(stat) +/- 0.008(syst) and C-psi KS0 = 0.008 +/- 0.012(stat) +/- 0.003(syst). This measurement of S-psi KS0 represents the most precise single measurement of the CKM angle beta to date and is more precise than the current world average. In addition, measurements of the CP-violation parameters of the individual channels are reported and a combination with the LHCb Run 1 measurements is performed.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2019). Measurement of CP violation in the B-s(0)-> phi phi decay and search for the B-0 -> phi phi decay. J. High Energy Phys., 12(12), 155–34pp.
Abstract: A measurement of the time-dependent CP-violating asymmetry in Bs0 ->phi phi = 7 TeV in 2011, 8 TeV in 2012 and 13 TeV in 2015 and 2016, a signal yield of around 9000 Bs0 ->phi phi decays is obtained. The CP-violating phase phi sss over bar is measured to be -0.073 +/- 0.115(stat) +/- 0.027(syst) rad, under the assumption it is independent of the helicity of the phi phi decay. In addition, the CP-violating phases of the transverse polarisations under the assumption of CP conservation of the longitudinal phase are measured. The helicity-independent direct CP-violation parameter is also measured, and is found to be |lambda| = 0.99 +/- 0.05(stat) +/- 0.01(syst). In addition, T-odd triple-product asymmetries are measured. The results obtained are consistent with the hypothesis of CP conservation in b over bar -> s over bar ss over bar transitions. Finally, a limit on the branching fraction of the B-0 -> phi phi decay is determined to be Bmml:mfenced close=“)” open=(B0 ->phi phi 2.7x10(-8) at 90% confidence level.
|
LHCb Collaboration(Aaij, R. et al), Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2021). Measurement of CP Violation in the Decay B plus -> K+ pi(0). Phys. Rev. Lett., 126(9), 091802–11pp.
Abstract: A measurement of CP violation in the decay B+ -> K+pi(0) is reported using data corresponding to an integrated luminosity of 5.4 fb- 1 collected with the LHCb experiment at a center-of-mass energy of root s = 13 TeV. The CP asymmetry is measured to be 0.025 +/- 0.015 +/- 0.006 +/- 0.003, where the uncertainties are statistical, systematic, and due to an external input. This is the most precise measurement of this quantity. It confirms and significantly enhances the observed anomalous difference between the direct CP asymmetries of the B-0 -> K+pi(-) and B+ -> K+pi 0 decays, known as the K pi puzzle.
|
LHCb Collaboration(Aaij, R. et al), Fernandez Casani, A., Jaimes Elles, S. J., Jashal, B. K., Libralon, S., Martinez-Vidal, F., et al. (2024). Measurement of CP Violation Observables in D+ → K- K+ π+ Decays. Phys. Rev. Lett., 133(25), 251801–13pp.
Abstract: A search for violation of the charge-parity (CP) symmetry in the D+ -> K- K+ pi(+) decay is presented, with proton-proton collision data corresponding to an integrated luminosity of 5.4 fb(-1), collected at a center-of-mass energy of 13 TeV with the LHCb detector. A novel model-independent technique is used to compare the D+ and D- phase-space distributions, with instrumental asymmetries subtracted using the D-s(+) -> K- K+ pi(+) decay as a control channel. The p value for the hypothesis of CP conservation is 8.1%. The CP asymmetry observables A(CP vertical bar S)(phi pi+) = (0.95 +/- 0.43(stat) +/- 0.26(syst)) x 10(-3) and A(CP vertical bar S)((K) over bar *0 K+) = (-0.26 +/- 0.56(stat) +/- 0.18(syst)) x 10(-3) are also measured. These results show no evidence of CP violation and represent the most sensitive search performed through the phase space of a multibody decay.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Measurement of CP-Averaged Observables in the B-0 -> K-star 0 mu(+)mu(-) Decay. Phys. Rev. Lett., 125(1), 011802–13pp.
Abstract: An angular analysis of the B-0 -> K-0 (-> K+pi(-))mu(+)mu(-) decay is presented using a dataset corresponding to an integrated luminosity of 4.7 fb(-1) of pp collision data collected with the LHCb experiment. The full set of CP-averaged observables are determined in bins of the invariant mass squared of the dimuon system. Contamination from decays with the K+ pi(-) system in an S-wave configuration is taken into account. The tension seen between the previous LHCb results and the standard model predictions persists with the new data. The precise value of the significance of this tension depends on the choice of theory nuisance parameters.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2019). Measurement of CP-Violating and Mixing-Induced Observables in B-s(0) -> phi gamma Decays. Phys. Rev. Lett., 123(8), 081802–10pp.
Abstract: A time-dependent analysis of the B-s(0) -> phi gamma decay rate is performed to determine the CP -violating observables S-phi gamma and C-phi gamma and the mixing-induced observable A(phi gamma)(Delta). The measurement is based on a sample of pp collision data recorded with the LHCb detector, corresponding to an integrated luminosity of 3 fb(-1) at center-of-mass energies of 7 and 8 TeV. The measured values are S-phi gamma = 0.43 +/- 0.30 +/- 0.11, C-phi gamma = 0.11 +/- 0.29 +/- 0.11, and A(phi gamma)(Delta) = -0.67(-0.41)(+0.37) +/- 0.17, where the first uncertainty is statistical and the second systematic. This is the first measurement of the observables S and C in radiative B-s(0) decays. The results are consistent with the standard model predictions.
|