toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author BABAR Collaboration (del Amo Sanchez, P. et al); Lopez-March, N.; Martinez-Vidal, F.; Oyanguren, A. url  doi
openurl 
  Title (up) Analysis of the D+ -> K- pi(+) e(+) nu(e) decay channel Type Journal Article
  Year 2011 Publication Physical Review D Abbreviated Journal Phys. Rev. D  
  Volume 83 Issue 7 Pages 072001 - 35pp  
  Keywords  
  Abstract Using 347: 5 fb(-1) of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10(3) signal events for the D+ -> K- pi(+)e(+)nu(e) decay channel are analyzed. This decay mode is dominated by the (K) over bar*(892)(0) contribution. We determine the (K) over bar*(892)(0) parameters: m(K*(892)0) (895.4 +/- 0.2 +/- 0.2) MeV/c(2),Gamma(0)(K*(892)0) (46.5 +/- 0.3 +/- 0.2) MeV/c(2), and the Blatt-Weisskopf parameter r(BW) = 2.1 +/- 0.5 +/- 0.5 (GeV/c)(-1), where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q(2) = 0 (r(V) = V(0)/A(1)(0) = 1.463 +/- 0.031, r(2) = A(2)(0)/A(1)(0) = 0.801 +/- 0.020 +/- 0.020) and the value of the axial-vector pole mass parametrizing the q(2) variation of A(1) and A(2): m(A) (2.63 +/- 0.10 +/- 0.13) GeV/c(2). The S-wave fraction is equal to (5.79 +/- 0.16 +/- 0: 15)%. Other signal components correspond to fractions below 1%. Using the D+ -> K-pi(+)pi(+) channel as a normalization, we measure the D+ semileptonic branching fraction: B(D+ K-pi(+)e(+)nu(e)) (4.00 +/- 0: 03 +/- 0.04 +/- 0.09) x 10(-2), where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A(1) at q(2) 0: A(1)(0) 0.6200 +/- 0.0056 +/- 0.0065 +/- 0.0071. Fixing the P-wave parameters, we measure the phase of the S wave for several values of the K pi mass. These results confirm those obtained with K pi production at small momentum transfer in fixed target experiments.  
  Address [Sanchez, P. del Amo; Lees, J. P.; Poireau, V.; Prencipe, E.; Tisserand, V.] Univ Savoie, Lab Annecy le Vieux Phys Particules LAPP, CNRS, IN2P3, F-74941 Annecy Le Vieux, France  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1550-7998 ISBN Medium  
  Area Expedition Conference  
  Notes ISI:000289055500002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 592  
Permanent link to this record
 

 
Author Pierre Auger Collaboration (Abreu, P. et al); Pastor, S. url  doi
openurl 
  Title (up) Anisotropy and chemical composition of ultra-high energy cosmic rays using arrival directions measured by the Pierre Auger Observatory Type Journal Article
  Year 2011 Publication Journal of Cosmology and Astroparticle Physics Abbreviated Journal J. Cosmol. Astropart. Phys.  
  Volume 06 Issue 6 Pages 022 - 17pp  
  Keywords ultra high energy cosmic rays; cosmic ray experiments  
  Abstract The Pierre Auger Collaboration has reported. evidence for anisotropy in the distribution of arrival directions of the cosmic rays with energies E > E-th = 5.5 x 10(19) eV. These show a correlation with the distribution of nearby extragalactic objects, including an apparent excess around the direction of Centaurus A. If the particles responsible for these excesses at E > E-th are heavy nuclei with charge Z, the proton component of the sources should lead to excesses in the same regions at energies E/Z. We here report the lack of anisotropies in these directions at energies above E-th/Z (for illustrative values of Z = 6, 13, 26). If the anisotropies above E-th are due to nuclei with charge Z, and under reasonable assumptions about the acceleration process, these observations imply stringent constraints on the allowed proton fraction at the lower energies.  
  Address [Abreu, P.; Andringa, S.; Assis, P.; Brogueira, P.; Cazon, L.; Conceicao, R.; Goncalves, P.; Pimenta, M.; Santo, C. E.; Santos, E.; Tome, B.] LIP, P-1000 Lisbon, Portugal, Email: auger_spokepersons@fnal.gov  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1475-7516 ISBN Medium  
  Area Expedition Conference  
  Notes ISI:000292332400022 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ elepoucu @ Serial 676  
Permanent link to this record
 

 
Author Li, X.Q.; Yang, Y.D.; Yuan, X.B. url  doi
openurl 
  Title (up) Anomalous (t q photon) coupling effects in exclusive radiative B-meson decays Type Journal Article
  Year 2011 Publication Journal of High Energy Physics Abbreviated Journal J. High Energy Phys.  
  Volume 08 Issue 8 Pages 075 - 22pp  
  Keywords Beyond Standard Model; B-Physics  
  Abstract The top-quark FCNC processes will be searched for at the CERN LHC, which are correlated with the B-meson decays. In this paper, we study the e ff ects of top-quark anomalous interactions tq gamma in the exclusive radiative B --> K*gamma and B --> rho gamma decays. With the current experimental data of the branching ratios, the direct CP and the isospin asymmetries, bounds on the coupling kappa(gamma)(tcR) from B --> K*gamma and kappa(gamma)(tuR) from B --> rho gamma decays are derived, respectively. The bound on vertical bar kappa(gamma)(tcR)vertical bar from B (B --> K*gamma) is generally compatible with that from B (B --> X(s)gamma). However, the isospin asymmetry Delta (K*gamma) further restrict the phase of kappa(gamma)(tuR), and the combined bound results in the upper limit, B (t --> c gamma) < 0 : 21%, which is lower than the CDF result. For real kappa(gamma)(tuR), the upper bound on B (t --> c gamma) is about of the same order as the 5 sigma discovery potential of ATLAS with an integrated luminosity of 10 fb(-1). For B --> rho gamma decays, the NP contribution is enhanced by a large CKM factor vertical bar V(ud)/V(td)vertical bar, and the constraint on tu gamma coupling is rather restrictive, B (t --> u gamma) < 1 : 44 x 10(-5). With re fi ned measurements to be available at the LHCb and the future super-B factories, we can get close correlations between B --> V gamma and the rare t --> q gamma decays, which will be studied directly at the LHC ATLAS and CMS.  
  Address [Li, XQ] Henan Normal Univ, Dept Phys, Xinxiang 453007, Henan, Peoples R China, Email: xqli@itp.ac.cn  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1126-6708 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000294901400007 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ elepoucu @ Serial 773  
Permanent link to this record
 

 
Author ANTARES Collaboration (Ageron, M. et al); Aguilar, J.A.; Bigongiari, C.; Carmona, E.; Dornic, D.; Emanuele, U.; Gomez-Gonzalez, J.P.; Hernandez-Rey, J.J.; Mangano, S.; Real, D.; Roca, V.; Salesa, F.; Toscano, S.; Urbano, F.; Yepes, H.; Zornoza, J.D.; Zuñiga, J. url  doi
openurl 
  Title (up) ANTARES: The first undersea neutrino telescope Type Journal Article
  Year 2011 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 656 Issue 1 Pages 11-38  
  Keywords Neutrino; Astroparticle; Neutrino astronomy; Deep sea detector; Marine technology; DWDM; Photomultiplier tube; Submarine cable; Wet mateable connector  
  Abstract The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given.  
  Address [Barbarito, E; Cassano, B; Ceres, A; Circella, M; Fiorello, C; Mongelli, M; Montaruli, T; Ruppi, M] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy, Email: Marco.Circella@ba.infn.it  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000296129100003 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ elepoucu @ Serial 785  
Permanent link to this record
 

 
Author Soriano, A.; Gonzalez, A.; Orero, A.; Moliner, L.; Carles, M.; Sanchez, F.; Benlloch, J.M.; Correcher, C.; Carrilero, V.; Seimetz, M. doi  openurl
  Title (up) Attenuation correction without transmission scan for the MAMMI breast PET Type Journal Article
  Year 2011 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 648 Issue Pages S75-S78  
  Keywords Breast PET; Attenuation correction  
  Abstract Whole-body Positron Emission Tomography (PET) scanners are required in order to span large Fields of View (FOV). Therefore, reaching the sensitivity and spatial resolution required for early stage breast tumor detection is not straightforward. MAMMI is a dedicated breast PET scanner with a ring geometry designed to provide PET images with a spatial resolution as high as 1.5 mm, being able to detect small breast tumors ( < 1 cm). The patient lays down in prone position during the scan, thus making possible to image the whole breast, up to regions close to the base of the pectoral without the requirement of breast compression. Attenuation correction (AC) for PET data improves the image quality and the quantitative accuracy of radioactivity distribution determination. In dedicated, high resolution breast cancer scanners, this correction would enhance the proper diagnosis in early disease stages. In whole-body PET scanners, AC is usually taken into account with the use of transmission scans, either by external radioactive rod sources or by Computed Tomography (CT). This considerably increases the radiation dose administered to the patient and time needed for the exploration. In this work we propose a method for breast shape identification by means of PET image segmentation. The breast shape identification will be used for the determination of the AC. For the case of a specific breast PET scanner the procedure we propose should provide AC similar to that obtained by transmission scans as we take advantage of the breast anatomical simplicity. Experimental validation of the proposed approach with a dedicated breast PET prototype is also presented. The main advantage of this method is an important dose reduction since the transmission scan is not required.  
  Address [Soriano, A.; Orero, A.; Moliner, L.; Carles, M.; Sanchez, F.; Benlloch, J. M.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna, Spain, Email: soriano@ific.uv.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000305376900021 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 1069  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva