Records |
Author |
ATF Collaboration (Bambade, P. e al); Alabau Pons, M.; Faus-Golfe, A. |
Title |
Present status and first results of the final focus beam line at the KEK Accelerator Test Facility |
Type |
Journal Article |
Year |
2010 |
Publication |
Physical Review Special Topics-Accelerators and Beams |
Abbreviated Journal |
Phys. Rev. Spec. Top.-Accel. Beams |
Volume |
13 |
Issue |
4 |
Pages |
042801 - 10pp |
Keywords |
|
Abstract |
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U. S. scientists. The present status and first results are described. |
Address |
[Bambade, P.; Renier, Y.; Rimbault, C.] Univ Paris 11, CNRS, LAL, IN2P3, F-91405 Orsay, France |
Corporate Author |
|
Thesis |
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1098-4402 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000278150700009 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
436 |
Permanent link to this record |
|
|
|
Author |
ATF2 Collaboration (White, G.R. et al); Blanch, C.; Faus-Golfe, A.; Resta-Lopez, J. |
Title |
Experimental Validation of a Novel Compact Focusing Scheme for Future Energy-Frontier Linear Lepton Colliders |
Type |
Journal Article |
Year |
2014 |
Publication |
Physical Review Letters |
Abbreviated Journal |
Phys. Rev. Lett. |
Volume |
112 |
Issue |
3 |
Pages |
034802 - 6pp |
Keywords |
|
Abstract |
A novel scheme for the focusing of high-energy leptons in future linear colliders was proposed in 2001 [P. Raimondi and A. Seryi, Phys. Rev. Lett. 86, 3779 (2001)]. This scheme has many advantageous properties over previously studied focusing schemes, including being significantly shorter for a given energy and having a significantly better energy bandwidth. Experimental results from the ATF2 accelerator at KEK are presented that validate the operating principle of such a scheme by demonstrating the demagnification of a 1.3 GeV electron beam down to below 65 nm in height using an energy-scaled version of the compact focusing optics designed for the ILC collider. |
Address |
[Blanch, C.; Faus-Golfe, A.; Resta-Lopez, J.] Univ Valencia, IFC, E-46980 Paterna, Spain |
Corporate Author |
|
Thesis |
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0031-9007 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000331944800003 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1891 |
Permanent link to this record |
|
|
|
Author |
Belver-Aguilar, C.; Faus-Golfe, A.; Toral, F.; Barnes, M.J. |
Title |
Stripline design for the extraction kicker of Compact Linear Collider damping rings |
Type |
Journal Article |
Year |
2014 |
Publication |
Physical Review Special Topics-Accelerators And Beams |
Abbreviated Journal |
Phys. Rev. Spec. Top.-Accel. Beams |
Volume |
17 |
Issue |
7 |
Pages |
071003 - 14pp |
Keywords |
|
Abstract |
In the framework of the design study of future linear colliders, the Compact Linear Collider (CLIC) aims for electron-positron collisions with high luminosity at a nominal center-of-mass energy of 3 TeV. To achieve the luminosity requirements, predamping rings ( PDRs) and damping rings ( DRs) are required: they reduce the beam emittance before the beam is accelerated in the main linac. Several kicker systems are needed to inject and extract the beam from the PDRs and DRs. In order to achieve both low beam coupling impedance and reasonable broadband impedance matching to the electrical circuit, striplines have been chosen for the kicker elements. In this paper, we present the complete design of the striplines for the DR extraction kicker, since it is the most challenging from the field homogeneity point of view. The excellent field homogeneity required, as well as a good transmission of the high voltage pulse through the electrodes, has been achieved by choosing a novel electrode shape. With this new geometry, it has been possible to benefit from all the advantages that the most common shapes introduce separately. Furthermore, a detailed study of the different operating modes of a stripline kicker allowed the beam coupling impedance to be reduced at low frequencies: this cannot be achieved by tapering the electrodes. The optimum design of the striplines and their components has been based on studies of impedance matching, field homogeneity, power transmission, beam coupling impedance, and manufacturing tolerances. Finally, new ideas for further improvement of the performance of future striplines are reported. |
Address |
[Belver-Aguilar, C.; Faus-Golfe, A.] Inst Fis Corpuscular, Paterna 46980, Spain |
Corporate Author |
|
Thesis |
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1098-4402 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000341249400001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1898 |
Permanent link to this record |
|
|
|
Author |
Faus-Golfe, A.; Navarro, J.; Fuster Martinez, N.; Resta Lopez, J.; Giner Navarro, J. |
Title |
Emittance reconstruction from measured beam sizes in ATF2 and perspectives for ILC |
Type |
Journal Article |
Year |
2016 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
Volume |
819 |
Issue |
|
Pages |
122-138 |
Keywords |
Beam size; Emittance; Linear Colliders |
Abstract |
The projected emittance (2D) and the intrinsic emittance (4D) reconstruction method by using the beam size measurements at different locations is analyzed in order to study analytically the conditions of solvability of the systems of equations involved in this process. Some conditions are deduced and discussed, and general guidelines about the locations of the measurement stations have been obtained to avoid unphysical results. The special case of the multi-Optical Transition Radiation system (m-OTR), made of four measurement stations, in the Extraction Line (EXT) of Accelerator Test Facility 2 (ATF2) has been simulated in much detail and compared with measurements. Finally a feasibility study of a multi station system for fast transverse beam size measurement, emittance reconstruction and coupling correction in the Ring to Main Linac (RTML) of International Linear Collider (ILC) Diagnostic sections of the RTML has been discussed in detail. |
Address |
[Faus-Golfe, A.; Navarro, J.; Fuster Martinez, N.; Giner Navarro, J.] Inst Fis Corpuscular CSIC UV, Madrid, Spain |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000372318800017 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
2581 |
Permanent link to this record |
|
|
|
Author |
LHCf Collaboration (Adriani, O. et al); Faus-Golfe, A.; Velasco, J. |
Title |
Measurement of zero degree single photon energy spectra for sqrt(s) = 7 TeV proton-proton collisions at LHC |
Type |
Journal Article |
Year |
2011 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
Volume |
703 |
Issue |
2 |
Pages |
128-134 |
Keywords |
LHC; Ultra-high energy cosmic-ray; Hadron interaction models |
Abstract |
In early 2010. the Large Hadron Collider forward (LHCf) experiment measured very forward neutral particle spectra in LHC proton-proton collisions. From a limited data set taken under the best beam conditions (low beam-gas background and low occurrence of pile-up events), the single photon spectra at root s = 7 TeV and pseudo-rapidity (eta) ranges from 8.81 to 8.99 and from 10.94 to infinity were obtained for the first time and are reported in this Letter. The spectra from two independent LHCf detectors are consistent with one another and serve as a cross check of the data. The photon spectra are also compared with the predictions of several hadron interaction models that are used extensively for modeling ultra-high energy cosmic-ray showers. Despite conservative estimates for the systematic errors, none of the models agree perfectly with the measurements. A notable difference is found between the data and the DPMJET 3.04 and PYTHIA 8.145 hadron interaction models above 2 TeV where the models predict higher photon yield than the data. The QGSJET II-03 model predicts overall lower photon yield than the data, especially above 2 TeV in the rapidity range 8.81 < eta < 8.99. |
Address |
[Fukatsu, K; Itow, Y; Kawade, K; Mase, T; Masuda, K; Matsubara, Y; Mitsuka, G; Muraki, Y; Sako, T; Suzuki, K; Taki, K] Nagoya Univ, Solar Terr Environm Lab, Nagoya, Aichi 4648601, Japan, Email: sako@stelab.nagoya-u.ac.jp |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0370-2693 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000295105500005 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
769 |
Permanent link to this record |
|
|
|
Author |
Liu, S.; Bogard, F.; Cornebise, P.; Faus-Golfe, A.; Fuster-Martinez, N.; Griesmayer, E.; Guler, H.; Kubytskyi, V.; Sylvia, C.; Tauchi, T.; Terunuma, N.; Bambade, P. |
Title |
In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility |
Type |
Journal Article |
Year |
2016 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
Volume |
832 |
Issue |
|
Pages |
231-242 |
Keywords |
Diamond sensor; Beam halo; ATF2 |
Abstract |
The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of similar to 10(6) has been successfully demonstrated and confirmed for the first time in simultaneous beam core (similar to 10(6) electrons) and beam halo (similar to 10(3) electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of diamond sensors using an a source, as well as using the electron beams at PHIL, a low energy (<5 MeV) photo-injector at LAL, and at ATF2. First beam halo measurement results using the DSv at ATF2 with different beam intensities and vacuum levels are also presented. Such measurements not only allow one to evaluate the different sources of beam halo generation but also to define the requirements for a suitable collimation system to be installed at ATF2, as well as to optimize its performance during future operation. |
Address |
[Liu, S.; Bogard, F.; Cornebise, P.; Faus-Golfe, A.; Guler, H.; Kubytskyi, V.; Sylvia, C.; Bambade, P.] Univ Paris Saclay, Univ Paris 11, CNRS, LAL,IN2P3, Orsay, France, Email: sliu@lal.in2p3.fr |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000382256400026 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
2786 |
Permanent link to this record |
|
|
|
Author |
Menjo, H. et al; Faus-Golfe, A.; Velasco, J. |
Title |
Monte Carlo study of forward pi(0) production spectra to be measured by the LHCf experiment for the purpose of benchmarking hadron interaction models at 10(17) eV |
Type |
Journal Article |
Year |
2011 |
Publication |
Astroparticle Physics |
Abbreviated Journal |
Astropart Phys. |
Volume |
34 |
Issue |
7 |
Pages |
513-520 |
Keywords |
High energy cosmic rays; LHC; LHCf; High energy pi(0) production spectra |
Abstract |
The LHCf experiment aims to improve knowledge of forward neutral particle production spectra at the LHC energy which is relevant for the interpretation of air shower development of high energy cosmic rays. Two detectors, each composed of a pair of sampling and imaging calorimeters, have been installed at the forward region of IP1 to measure pi(0) energy spectra above 600 GeV. In this paper, we present a Monte Carlo study of the pi(0) measurements to be performed with one of the LHCf detectors for proton-proton collisions at root s = 14 TeV. In approximately 40 min of operation at luminosity 0.8 x 10(29) cm(-2) s(-1) during the beam commissioning phase of LHC, about 1.5 x 10(4) pi(0) events are expected to be obtained at two transverse positions of the detector. The backgrounds from interactions of secondary particles with beam pipes and interactions of beam particles with residual gas in the beam pipes are expected to be less than 0.1% of the signal from pi(0)s. We also discuss the capability of LHCf measurements to discriminate between the various hadron interaction models that are used for simulation of high energy air showers, such as DPMJET3.03, QGSJETII-03, SIBYLL2.1 and EPOS1.99. |
Address |
[Menjo, H.; Adriani, O.; Bonechi, L.; Bongi, M.; Castellini, G.; D'Alessandro, R.; Papini, P.; Ricciarini, S.; Viciani, A.] Ist Nazl Fis Nucl, Sez Firenze, I-50019 Florence, Italy, Email: menjo@fi.infn.it |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0927-6505 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000287955500001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
596 |
Permanent link to this record |
|
|
|
Author |
Verdu-Andres, S.; Amaldi, U.; Faus-Golfe, A. |
Title |
CABOTO, a high-gradient linac for hadrontherapy |
Type |
Journal Article |
Year |
2013 |
Publication |
Journal of Radiation Research |
Abbreviated Journal |
J. Radiat. Res. |
Volume |
54 |
Issue |
|
Pages |
155-161 |
Keywords |
hadrontherapy; high-gradient linac; cyclinac; carbon ion therapy; multipainting |
Abstract |
The field of hadrontherapy has grown rapidly in recent years. At present the therapeutic beam is provided by a cyclotron or a synchrotron, but neither cyclotrons nor synchrotrons present the best performances for hadrontherapy. The new generation of accelerators for hadrontherapy should allow fast active energy modulation and have a high repetition rate, so that moving organs can be appropriately treated in a reasonable time. In addition, a reduction of the dimensions and cost of the accelerators for hadrontherapy would make the acquisition and operation of a hadrontherapy facility more affordable, which would translate into great benefits for the potential hadrontherapy patients. The 'cyclinac', an accelerator concept that combines a cyclotron with a high-frequency linear accelerator (linac), is a fast-cycling machine specifically conceived to allow for fast active energy modulation. The present paper focuses on CABOTO (CArbon BOoster for Therapy in Oncology), a compact, efficient high-frequency linac that can accelerate C6+ ions and H-2 molecules from 150-410 MeV/u in similar to 24 m. The paper presents the latest design of CABOTO and discusses its performances. |
Address |
[Verdu-Andres, Silvia; Amaldi, Ugo] Fdn Tera, I-28100 Novara, Italy, Email: sverdu@bnl.gov |
Corporate Author |
|
Thesis |
|
Publisher |
Oxford Univ Press |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0449-3060 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000321463900021 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1506 |
Permanent link to this record |
|
|
|
Author |
Vnuchenko, A.; Esperante Pereira, D.; Gimeno, B.; Benedetti, S.; Catalan Lasheras, N.; Garlasch, M.; Grudiev, A.; McMonagle, G.; Pitman, S.; Syratchev, I.; Timmins, M.; Wegner, R.; Woolley, B.; Wuensch, W.; Faus-Golfe, A. |
Title |
High-gradient testing of an S-band, normal-conducting low phase velocity accelerating structure |
Type |
Journal Article |
Year |
2020 |
Publication |
Physical Review Accelerators and Beams |
Abbreviated Journal |
Phys. Rev. Accel. Beams |
Volume |
23 |
Issue |
8 |
Pages |
084801 - 13pp |
Keywords |
|
Abstract |
A novel high-gradient accelerating structure with low phase velocity, v/c = 0.38, has been designed, manufactured and high-power tested. The structure was designed and built using the methodology and technology developed for CLIC 100 MV/m high-gradient accelerating structures, which have speed of light phase velocity, but adapts them to a structure for nonrelativistic particles. The parameters of the structure were optimized for the compact proton therapy linac project, and specifically to 76 MeV energy protons, but the type of structure opens more generally the possibility of compact low phase velocity linacs. The structure operates in S-band, is backward traveling wave (BTW) with a phase advance of 150 degrees and has an active length of 19 cm. The main objective for designing and testing this structure was to demonstrate that low velocity particles, in particular protons, can be accelerated with high gradients. In addition, the performance of this structure compared to other type of structures provides insights into the factors that limit high gradient operation. The structure was conditioned successfully to high gradient using the same protocol as for CLIC X-band structures. However, after the high power test, data analysis realized that the structure had been installed backwards, that is, the input power had been fed into what is nominally the output end of the structure. This resulted in higher peak fields at the power feed end and a steeply decreasing field profile along the structure, rather than the intended near constant field and gradient profile. A local accelerating gradient of 81 MV/m near the input end was achieved at a pulse length of 1.2 μs and with a breakdown rate (BDR) of 7.2 x 10(-7) 1 /pulse/m. The reverse configuration was accidental but the operating with this field condition gave very important insights into high-gradient behaviour and a comprehensive analysis has been carried out. A particular attention was paid to the characterization of the distribution of BD positions along the structure and within a cell. |
Address |
[Vnuchenko, A.; Esperante Pereira, D.; Gimeno Martinez, B.] Inst Fsica Corpuscular IFIC, Valencia 46980, Spain, Email: anna.vnuchenko@cern.ch |
Corporate Author |
|
Thesis |
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2469-9888 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000582958800002 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
4584 |
Permanent link to this record |