Records |
Links |
|
Author |
Kowalska, M.; Naimi, S.; Agramunt, J.; Algora, A.; Beck, D.; Blank, B.; Blaum, K.; Bohm, C.; Borgmann, C.; Breitenfeldt, M.; Fraile, L.M.; George, S.; Herfurth, F.; Herlert, A.; Kreim, S.; Lunney, D.; Minaya-Ramirez, E.; Neidherr, D.; Rosenbusch, M.; Rubio, B.; Schweikhard, L.; Stanja, J.; Zuber, K. |
|
|
Title |
Trap-assisted decay spectroscopy with ISOLTRAP |
Type |
Journal Article |
|
Year |
2012 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
689 |
Issue |
|
Pages |
102-107 |
|
|
Keywords |
Penning trap mass spectrometers; Trap-assisted decay spectroscopy; Studies at ISOL-type facilities |
|
|
Abstract |
Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements. |
|
|
Address |
[Kowalska, M.; Herlert, A.] CERN, Dept Phys, CH-1211 Geneva 23, Switzerland, Email: kowalska@cern.ch |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000307797500016 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1134 |
|
Permanent link to this record |
|
|
|
|
Author |
Luo, X.L. et al; Agramunt, J.; Egea, F.J.; Gadea, A.; Huyuk, T. |
|
|
Title |
Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
897 |
Issue |
|
Pages |
59-65 |
|
|
Keywords |
Pile-up; Digital; First-order derivative; Neutron-gamma discrimination; Liquid scintillator |
|
|
Abstract |
The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or gamma rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-gamma discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events. |
|
|
Address |
[Luo, X. L.] Acad Mil Med Sci, Natl Innovat Inst Def Technol, Beijing 100010, Peoples R China, Email: delongtmac@163.com |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000433206800010 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3591 |
|
Permanent link to this record |
|
|
|
|
Author |
Luo, X.L. et al; Agramunt, J.; Egea, F.J.; Gadea, A.; Huyuk, T. |
|
|
Title |
Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA) |
Type |
Journal Article |
|
Year |
2014 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
767 |
Issue |
|
Pages |
83-91 |
|
|
Keywords |
Digital neutron-gamma discrimination; Liquid scintillator; Photomultiplier tube; Charge Comparison; Integrated rise-time; Time-of-flight; NEDA |
|
|
Abstract |
A comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA. |
|
|
Address |
[Luo, X. L.] Natl Univ Def Technol, Coll Mechatron & Automat, Dept Instrument Sci & Technol, Changsha, Hunan, Peoples R China, Email: luo.xiaoliang@physics.uu.se |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000344994600012 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
2011 |
|
Permanent link to this record |
|
|
|
|
Author |
Martinez, T. et al; Agramunt, J.; Algora, A.; Domingo-Pardo, C.; Jordan, M.D.; Rubio, B.; Tain, J.L. |
|
|
Title |
MONSTER: a TOF Spectrometer for beta-delayed Neutron Spectroscopy |
Type |
Journal Article |
|
Year |
2014 |
Publication |
Nuclear Data Sheets |
Abbreviated Journal |
Nucl. Data Sheets |
|
|
Volume |
120 |
Issue |
|
Pages |
78-80 |
|
|
Keywords |
|
|
|
Abstract |
beta-delayed neutron (DN) data, including emission probabilities, P-n, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations. |
|
|
Address |
[Martinez, T.; Cano-Ott, D.; Castilla, J.; Garcia, A. R.; Marin, J.; Martinez, G.; Mendoza, E.; Santos, C.; Tera, F. J.; Villamarin, D.] CIEMAT, Ctr Invest Energet, Medio Ambient Tecnol, E-28040 Madrid, Spain, Email: trino.martinez@ciemat.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Academic Press Inc Elsevier Science |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0090-3752 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000339860100021 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1872 |
|
Permanent link to this record |
|
|
|
|
Author |
Mistry, A. K. et al; Tain, J.L.; Agramunt, J.; Algora, A.; Guadilla, V.; Morales, A.I.; Nacher, E.; Orrigo, S.E.A.; Rubio, B. |
|
|
Title |
The DESPEC setup for GSI and FAIR |
Type |
Journal Article |
|
Year |
2022 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
1033 |
Issue |
|
Pages |
166662 - 18pp |
|
|
Keywords |
alpha, beta, gamma spectroscopy; Digital electronics; Fast timing; FAIR; DESPEC; NuSTAR |
|
|
Abstract |
The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr3(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000794062100014 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
5343 |
|
Permanent link to this record |