Bottoni, S. et al, Gadea, A., & Perez-Vidal, R. M. (2024). Search for the γ decay of the narrow near-threshold proton resonance in 11B. Phys. Lett. B, 855, 138851–4pp.
Abstract: The y decay of the elusive narrow, near-threshold proton resonance in 11 B was investigated at Laboratori Nazionali di Legnaro (INFN) in a particle-y coincidence experiment, using the 6 Li( 6 Li,py) fusion-evaporation reaction and the GALILEO-GALTRACE setup. No clear signature was found for a possible E1 decay to the 1/2-1, – 1 , first-excited state of 11 B, predicted by the Shell Model Embedded in the Continuum (SMEC) with a branching of 0.98+167 +167 -69 x 10-3 -3 with respect to the dominant particle-decaying modes. The statistical analysis of the y-ray spectrum provided an average upper limit of 2.37 x 10-3 -3 for this y-ray branching, with a global significance of 5 sigma. On the other hand, by imposing a global confidence level of 3 sigma, a significant excess of counts was observed for Ey y = 9300(20) keV, corresponding to a resonance energy of 11429(20) keV (namely 200(20) keV above the proton separation energy of 11 B) and a y-ray branching of 1.12(35) x10-3. -3 . This result is compatible with the SMEC calculations, potentially supporting the existence of a near-threshold proton resonance in 11 B.
|
Yaneva, A. et al, & Algora, A. (2024). The shape of the Tz =+1 nucleus 94Pd and the role of proton-neutron interactions on the structure of its excited states. Phys. Lett. B, 855, 138805–7pp.
Abstract: Reduced transition probabilities have been extracted between excited, yrast states in the N = Z + 2 nucleus Pd-94. The transitions of interest were observed following decays of the I-pi = 14(+), E-x = 2129-keV isomeric state, which was populated following the projectile fragmentation of a Xe-124 primary beam at the GSI Helmholtzzentrum fur Schwerionenforschung accelerator facility as part of FAIR Phase-0. Experimental information regarding the reduced E2 transition strengths for the decays of the yrast 8(+) and 6(+) states was determined following isomer-delayed E-gamma 1 – E-gamma 2 – Delta T-2,T-1 coincidence method, using the LaBr3(Ce)-based FATIMA fast-timing coincidence gamma-ray array, which allowed direct determination of lifetimes of states in Pd-94 using the Generalized Centroid Difference (GCD) method. The experimental value for the half-life of the yrast 8(+) state of 755(106) ps results in a reduced transition probability of B(E2:8(+)-> 6(+)) = 205(-25)(+34) e(2) fm(4), which enables a precise verification of shell-model calculations for this unique system, lying directly between the N = Z line and the N = 50 neutron shell closure. The determined B(E2) value provides an insight into the purity of (g(9/2))(n) configurations in competition with admixtures from excitations between the (lower) N = 3pf and (higher) N = 4gds orbitals for the first time. The results indicate weak collectivity expected for near-zero quadrupole deformation and an increasing importance of the T = 0 proton-neutron interaction at N = 48.
|
Hueso-Gonzalez, F., Berthold, J., Wohlfahrt, P., Bortfeld, T., Khamfongkhruea, C., Tattenberg, S., et al. (2024). Inter-center comparison of proton range verification prototypes with an anthropomorphic head phantom. Phys. Med. Biol., 69(22), 225010–14pp.
Abstract: Objective. To compare in reproducible and equalized conditions the performance of two independent proton range verification systems based on prompt gamma-ray detectors from two different proton therapy centers. Approach. An anthropomorphic head phantom with calibrated stopping power, serving as ground truth, was irradiated with comparable treatment plans, spot positions and energies in both facilities. Clinical beam current, tumor contour and dose were used. The absolute range measurement was compared to the expected value according to the ground truth. The statistical precision was assessed by repeating each measurement ten times. Sensitivity to relative range shifts was evaluated by introducing 2 mm and 5 mm plastic slabs on half of the field. Main results. The resulting absolute range accuracy was within 2.4 mm in all cases. Relative range shifts were detected with deviations lower than 14%. Significance. The performance of both systems was deemed worthy of clinical application for the detection of range deviations. This study represents the first comparison of independent prompt gamma-ray-based proton range verification systems under equalized conditions with realistic treatment fields and beam currents.
|
Gammaldi, V., Zaldivar, B., Sanchez-Conde, M. A., & Coronado-Blazquez, J. (2023). A search for dark matter among Fermi-LAT unidentified sources with systematic features in machine learning. Mon. Not. Roy. Astron. Soc., 520(1), 1348–1361.
Abstract: Around one-third of the point-like sources in the Fermi-LAT catalogues remain as unidentified sources (unIDs) today. Indeed, these unIDs lack a clear, univocal association with a known astrophysical source. If dark matter (DM) is composed of weakly interacting massive particles (WIMPs), there is the exciting possibility that some of these unIDs may actually be DM sources, emitting gamma-rays from WIMPs annihilation. We propose a new approach to solve the standard, machine learning (ML) binary classification problem of disentangling prospective DM sources (simulated data) from astrophysical sources (observed data) among the unIDs of the 4FGL Fermi-LAT catalogue. We artificially build two systematic features for the DM data which are originally inherent to observed data: the detection significance and the uncertainty on the spectral curvature. We do it by sampling from the observed population of unIDs, assuming that the DM distributions would, if any, follow the latter. We consider different ML models: Logistic Regression, Neural Network (NN), Naive Bayes, and Gaussian Process, out of which the best, in terms of classification accuracy, is the NN, achieving around 93 . 3 per cent +/- 0 . 7 per cent performance. Other ML evaluation parameters, such as the True Ne gativ e and True Positive rates, are discussed in our work. Applying the NN to the unIDs sample, we find that the de generac y between some astrophysical and DM sources can be partially solved within this methodology. None the less, we conclude that there are no DM source candidates among the pool of 4FGL Fermi-LAT unIDs.
|
AGATA Collaboration(Valiente-Dobon, J. J. et al), Perez-Vidal, R. M., Blasco Miquel, J., Civera, J. V., & Gadea, A. (2023). Conceptual design of the AGATA 2 pi array at LNL. Nucl. Instrum. Methods Phys. Res. A, 1049, 168040–14pp.
Abstract: The Advanced GAmma Tracking Array (AGATA) has been installed at Laboratori Nazionali di Legnaro (LNL), Italy. In this installation, AGATA will consist, at the beginning, of 13 AGATA triple clusters (ATCs) with an angular coverage of 1n,and progressively the number of ATCs will increase up to a 2 pi angular coverage. This setup will exploit both stable and radioactive ion beams delivered by the Tandem-PIAVE-ALPI accelerator complex and the SPES facility. The new implementation of AGATA at LNL will be used in two different configurations, firstly one coupled to the PRISMA large-acceptance magnetic spectrometer and lately a second one at Zero Degrees, along the beam line. These two configurations will allow us to cover a broad physics program, using different reaction mechanisms, such as Coulomb excitation, fusion-evaporation, transfer and fission at energies close to the Coulomb barrier. These setups have been designed to be coupled with a large variety of complementary detectors such as charged particle detectors, neutron detectors, heavy-ion detectors, high-energy gamma-ray arrays, cryogenic and gasjet targets and the plunger device for lifetime measurements. We present in this paper the conceptual design, characteristics and performance figures of this implementation of AGATA at LNL.
|