|
Records |
Links |
|
Author |
LHCb Collaboration (Aaij, R. et al); Garcia Martin, L.M.; Henry, L.; Martinez-Vidal, F.; Oyanguren, A.; Remon Alepuz, C.; Ruiz Valls, P.; Ruiz Vidal, J.; Sanchez Mayordomo, C. |
|
|
Title |
First measurement of the CP-violating phase phi(dd)(s) in B-s(0) -> (K+pi(-))(K-pi(+)) decays |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Journal of High Energy Physics |
Abbreviated Journal |
J. High Energy Phys. |
|
|
Volume |
03 |
Issue |
3 |
Pages |
140 - 32pp |
|
|
Keywords |
CP violation; Flavour Changing Neutral Currents; B physics; Oscillation; Hadron-Hadron scattering (experiments) |
|
|
Abstract |
A flavour-tagged decay-time-dependent amplitude analysis of B-s(0) -> (K+pi(-))(K-pi(+)) decays is presented in the K-+/-pi(-/+) mass range from 750 to 1600 MeV/c(2). The analysis uses pp collision data collected with the LHCb detector at centre-of-mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3.0 fb(-1). Several quasi-two-body decay modes are considered, corresponding to K-+/-pi(-/+) combinations with spin 0, 1 and 2, which are dominated by the K-0(*)(800)(0) and K-0(*)(1430)(0), the K*(892)(0) and the K-2(*)(1430)(0) resonances, respectively. The longitudinal polarisation fraction for the B-s(0) -> K-*(892)(0) (K*) over bar (892)(0) decay is measured as f(L) = 0.208 +/- 0.032 +/- 0.046, where the first uncertainty is statistical and the second is systematic. The first measurement of the mixing-induced CP-violating phase in phi(d (d) over bar)(s), in b -> d (s) over bars transitions is performed, yielding a value of phi(d (d) over bar)(s)= -0.10 +/- 0.13 (stat) +/- 0.14 (syst) rad. |
|
|
Address |
[Bediaga, I.; Torres, M. Cruz; De Miranda, J. M.; Gomes, A.; Massafferi, A.; Rodriguez, J. Molina; Dos Reis, A. C.; Lavra, L. Soares; Aoude, R. Tourinho Jadallah] CBPF, Rio De Janeiro, Brazil, Email: julian.garcia.pardinas@cern.ch |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1029-8479 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000428798900003 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3550 |
|
Permanent link to this record |
|
|
|
|
Author |
de Salas, P.F.; Gariazzo, S.; Laveder, M.; Pastor, S.; Pisanti, O.; Truong, N. |
|
|
Title |
Cosmological bounds on neutrino statistics |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Journal of Cosmology and Astroparticle Physics |
Abbreviated Journal |
J. Cosmol. Astropart. Phys. |
|
|
Volume |
03 |
Issue |
3 |
Pages |
050 - 18pp |
|
|
Keywords |
cosmological neutrinos; neutrino properties; big bang nucleosynthesis; cosmological parameters from CMBR |
|
|
Abstract |
We consider the phenomenological implications of the violation of the Pauli exclusion principle for neutrinos, focusing on cosmological observables such as the spectrum of Cosmic Microwave Background anisotropies, Baryon Acoustic Oscillations and the primordial abundances of light elements. Neutrinos that behave (at least partly) as bosonic particles have a modified equilibrium distribution function that implies a different influence on the evolution of the Universe that, in the case of massive neutrinos, can not be simply parametrized by a change in the effective number of neutrinos. Our results show that, despite the precision of the available cosmological data, only very weak bounds can be obtained on neutrino statistics, disfavouring a more bosonic behaviour at less than 2 sigma. |
|
|
Address |
[de Salas, P. F.; Gariazzo, S.; Pastor, S.] Univ Valencia, CSIC, Inst Fis Corpuscular, Parc Cient UV,C Catedrat Jose Beltran 2, E-46980 Paterna, Valencia, Spain, Email: pabferde@ific.uv.es; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1475-7516 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000428984100005 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3551 |
|
Permanent link to this record |
|
|
|
|
Author |
Quintero-Quintero, A.; Patiño-Camargo, G.; Soriano, A.; Palma, J.D.; Vilar-Palop, J.; Pujades, M.C.; Llorca-Domaica, N.; Ballester, F.; Vijande, J.; Candela-Juan, C. |
|
|
Title |
Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Journal of Radiological Protection |
Abbreviated Journal |
J. Radiol. Prot. |
|
|
Volume |
38 |
Issue |
2 |
Pages |
549-563 |
|
|
Keywords |
backscatter correction factor; TLD; lead apron; fluoroscopy; eye lens dose |
|
|
Abstract |
Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of the Monte Carlo (MC) code Penelope. The results obtained were validated against measurements performed in reference conditions in a secondary standard dosimetry laboratory. Next, the MC model was used to evaluate the backscatter correction factor needed for the case where the dosimeter is worn over a lead shield to estimate the personal equivalent dose H-p(0.07) to unprotected soft tissues. For this purpose, the TLD was irradiated over a water slab phantom with a photon beam representative of the result of a fluoroscopy beam scattered by a patient. Incident beam angles of 0 degrees and 60 degrees, and lead thicknesses between the TLD and phantom of 0.25 and 0.5 mm Pb were considered. A backscatter correction factor of 1.23 (independent of lead thickness) was calculated comparing the results with those faced in reference conditions (i.e., without lead shield and with an angular incidence of 0 degrees). The corrected dose algorithm was validated in laboratory conditions with dosi-meters irradiated over a thyroid collar and angular incidences of 0 degrees, 40 degrees and 60 degrees, as well as with dosimeters worn by interventional radiologists and cardiologists. The corrected dose algorithm provides a better approach to estimate the equivalent dose to unprotected soft tissues such as eye lenses. Dosimeters that are not shielded from backscatter radiation might underestimate personal equivalent doses when worn over a lead apron and, therefore, should be specifically characterized for this purpose. |
|
|
Address |
[Quintero-Quintero, A.; Patino-Camargo, G.] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Valencia, Spain, Email: ccanjuan@gmail.com |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0952-4746 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000428913900001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3552 |
|
Permanent link to this record |
|
|
|
|
Author |
Izadi, A.; Shacker, S.S.; Olmo, G.J.; Banerjee, R. |
|
|
Title |
Observational effects of varying speed of light in quadratic gravity cosmological models |
Type |
Journal Article |
|
Year |
2018 |
Publication |
International Journal of Geometric Methods in Modern Physics |
Abbreviated Journal |
Int. J. Geom. Methods Mod. Phys. |
|
|
Volume |
15 |
Issue |
5 |
Pages |
1850084 - 16pp |
|
|
Keywords |
Palatini formalism; modified gravity; causal structure constant; varying speed of light |
|
|
Abstract |
We study different manifestations of the speed of light in theories of gravity where metric and connection are regarded as independent fields. We find that for a generic gravity theory in a frame with locally vanishing affine connection, the usual degeneracy between different manifestations of the speed of light is broken. In particular, the space-time causal structure constant (c(ST)) may become variable in that local frame. For theories of the form f(R, R-mu nu R-mu nu), this variation in c(ST) has an impact on the definition of the luminosity distance (and distance modulus), which can be used to confront the predictions of particular models against Supernovae type Ia (SN Ia) data. We carry out this test for a quadratic gravity model without cosmological constant assuming (i) a constant speed of light and (ii) a varying speed of light (VSL), and find that the latter scenario is favored by the data. |
|
|
Address |
[Izadi, Azam] Khajeh Nasir Toosi Univ Technol, Dept Phys, Tehran, Iran, Email: aizadi@kntu.ac.ir; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
World Scientific Publ Co Pte Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0219-8878 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000429106400016 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3553 |
|
Permanent link to this record |
|
|
|
|
Author |
Davesne, D.; Navarro, J.; Meyer, J.; Bennaceur, K.; Pastore, A. |
|
|
Title |
Two-body contributions to the effective mass in nuclear effective interactions |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Physical Review C |
Abbreviated Journal |
Phys. Rev. C |
|
|
Volume |
97 |
Issue |
4 |
Pages |
044304 - 7pp |
|
|
Keywords |
|
|
|
Abstract |
Starting from general expressions of well-chosen symmetric nuclear matter quantities derived for both zero-and finite-range effective theories, we derive some universal relations between them. We first showthat, independently of the range, the two-body contribution is enough to describe correctly the saturation mechanism but gives an effective mass value around m(*)/m similar or equal to 0.4 when the other properties of the saturation point are set near their generally accepted values. Then, we show that a more elaborated interaction (for instance, an effective two-body density-dependent term on top of the pure two-body term) is needed to reach the accepted value m(*)/m similar or equal to 0.7-0.8. |
|
|
Address |
[Davesne, D.; Meyer, J.; Bennaceur, K.] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS, IPNL,UMR 5822, 4 Rue E Fermi, F-69622 Villeurbanne, France, Email: davesne@ipnl.in2p3.fr; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2469-9985 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000429456600002 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3554 |
|
Permanent link to this record |