|
n_TOF Collaboration(Guerrero, C. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2013). Performance of the neutron time-of-flight facility n_TOF at CERN. Eur. Phys. J. A, 49(2), 27–15pp.
Abstract: The neutron time-of-flight facility n_TOF features a white neutron source produced by spallation through 20 GeV/c protons impinging on a lead target. The facility, aiming primarily at the measurement of neutron-induced reaction cross sections, was operating at CERN between 2001 and 2004, and then underwent a major upgrade in 2008. This paper presents in detail all the characteristics of the new neutron beam in the currently available configurations, which correspond to two different collimation systems and two choices of neutron moderator. The characteristics discussed include the intensity and energy dependence of the neutron flux, the spatial profile of the beam, the in-beam background components and the energy resolution/broadening. The discussion of these features is based on dedicated measurements and Monte Carlo simulations, and includes estimations of the systematic uncertainties of the mentioned quantities.
|
|
|
n_TOF Collaboration(Barbagallo, M. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2013). High-accuracy determination of the neutron flux at n_TOF. Eur. Phys. J. A, 49(12), 156–11pp.
Abstract: The neutron flux of the nTOF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the nTOF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n_TOF. An unexpected anomaly in the neutron-induced fission cross section of U-235 is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties.
|
|
|
n_TOF Collaboration(Calviani, M. et al), Giubrone, G., & Tain, J. L. (2012). Neutron-induced fission cross section of Cm-245: New results from data taken at the time-of-flight facility n_TOF. Phys. Rev. C, 85(3), 034616–10pp.
Abstract: The neutron-induced fission cross section of Cm-245 was measured at n_TOF in a wide energy range and with high resolution. The energy dependence, measured in a single measurement from 30 meV to 1 MeV neutron energy, has been determined with 5% accuracy relative to the U-235(n,f) cross section. In order to reduce the uncertainty on the absolute value, the data have been normalized at thermal energy to recent measurements performed at ILL and BR1. In the energy range of overlap, the results are in fair agreement with some previous measurements and confirm, on average, the evaluated cross section in the ENDF/B-VII.0 database, although sizable differences are observed for some important resonances below 20 eV. A similar behavior is observed relative to JENDL/AC-2008, a reactor-oriented database for actinides. The new results contribute to the overall improvement of the databases needed for the design of advanced reactor systems and may lead to refinements of fission models for the actinides.
|
|
|
n_TOF Collaboration(Guerrero, C. et al), Giubrone, G., & Tain, J. L. (2012). Simultaneous measurement of neutron-induced capture and fission reactions at CERN. Eur. Phys. J. A, 48(3), 29–9pp.
Abstract: The measurement of the capture cross-section of fissile elements, of utmost importance for the design of innovative nuclear reactors and the management of nuclear waste, faces particular difficulties related to the.-ray background generated in the competing fission reactions. At the CERN neutron time-of-flight facility nTOF we have combined the Total Absorption Calorimeter (TAC) capture detector with a set of three U-235 loaded MicroMegas (MGAS) fission detectors for measuring simultaneously two reactions: capture and fission. The results presented here include the determination of the three detection efficiencies involved in the process: epsilon(TAC)(n, f), epsilon(TAC)(n, gamma) and epsilon(MGAS)(n, f). In the test measurement we have succeeded in measuring simultaneously with a high total efficiency the U-235 capture and fission cross-sections, disentangling accurately the two types of reactions. The work presented here proves that accurate capture cross-section measurements of fissile isotopes are feasible at nTOF.
|
|
|
n_TOF Collaboration(Chiaveri, E. et al), Giubrone, G., & Tain, J. L. (2011). Past, Present and Future of the n_TOF Facility at CERN. J. Korean Phys. Soc., 59(2), 1620–1623.
Abstract: The nTOF spallation neutron facility is operating at CERN since 2001. Neutrons are produced with a very wide energy range, from thermal up to 1 GeV and with a very high instantaneous flux (10(5)n/cm(2)/pulse at 200 m from target) thanks to the high intensity (7 x 10(12) protons/pulse) and low repetition rate of the Proton Synchrotron (PS) which is delivering protons to a lead spallation target. The experimental area is located at 200 m from the target, resulting in a very good energy resolution and beam quality thanks to the adoption of an optimal collimation system. At the end of 2008 the nTOF facility has resumed operation after a halt of 3 years due to technical issues. This contribution will outline the main physics results obtained by the facility since its inception in 1999, and show the importance of the measured nuclear data in the field of Nuclear Astrophysics and Nuclear Technology. Then it will present the future perspectives of the facility, aiming mainly in the direction of measuring highly radioactive samples, for which the facility has unique capabilities, with a lower background.
|
|