|
Wimmer, K. et al, Algora, A., & Rubio, B. (2018). Shape coexistence and isospin symmetry in A=70 nuclei: Spectroscopy of the T-z =-1 nucleus Kr-70. Phys. Lett. B, 785, 441–446.
Abstract: Excited states in the T-z = -1 nucleus Kr-70 have been populated using inelastic scattering of a radioactive Kr-70 beam as well as one- and two-neutron removal reactions from Kr-71,Kr-72 at intermediate beam energies. The level scheme of Kr-70 was constructed from the observed gamma-ray transitions and coincidences. Tentative spin and parity assignments were made based on comparison with the mirror nucleus Se-70. Asecond 2(+) state and a candidate for the corresponding 4(2)(+) state suggest shape coexistence in Kr-70.
|
|
|
Luo, X. L. et al, Agramunt, J., Egea, F. J., Gadea, A., & Huyuk, T. (2014). Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA). Nucl. Instrum. Methods Phys. Res. A, 767, 83–91.
Abstract: A comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.
|
|
|
Debastiani, V. R., Liang, W. H., Xie, J. J., & Oset, E. (2017). Predictions for eta(c) -> eta pi(+)pi(-) producing f(0)(500), f(0)(980) and a(0)(980). Phys. Lett. B, 766, 59–64.
Abstract: We perform calculations for the eta(c) -> eta pi(+)pi(-) decay using elements of SU(3) symmetry to see the weight of different trios of pseudoscalars produced in this decay, prior to the final state interaction of the mesons. After that, the interaction of pairs of mesons, leading finally to eta pi(+)pi(-), is done using the chiral unitary approach. We evaluate the pi(+)pi(-) and pi eta mass distributions and find large and clear signals for f(0)(500), f(0)(980) and a(0)(980) excitation. The reaction is similar to the chi(c1) -> eta pi(+)pi(-), which has been recently measured at BESIII and its implementation and comparison with these predictions will be very valuable to shed light on the nature of the low mass scalar mesons.
|
|
|
Ullan, M., Benitez, V., Quirion, D., Zabala, M., Pellegrini, G., Lozano, M., et al. (2014). Low-resistance strip sensors for beam-loss event protection. Nucl. Instrum. Methods Phys. Res. A, 765, 252–257.
Abstract: AC coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the “far” end of the strip from the punchthrough structure leading to large voltages. We present here our developments to fabricate lowresistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology.
|
|
|
Mengoni, D., Duenas, J. A., Assie, M., Boiano, C., John, P. R., Aliaga, R. J., et al. (2014). Digital pulse-shape analysis with a TRACE early silicon prototype. Nucl. Instrum. Methods Phys. Res. A, 764, 241–246.
Abstract: A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.
|
|