|
Records |
Links |
|
Author |
Guerrero, C.; Tessler, M.; Paul, M.; Lerendegui-Marco, J.; Heinitz, S.; Maugeri, E.A.; Domingo-Pardo, C.; Dressler, R.; Halfon, S.; Kivel, N.; Koster, U.; Palchan-Hazan, T.; Quesada, J.M.; Schumann, D.; Weissman, L. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
The s-process in the Nd-Pm-Sm region: Neutron activation of Pm-147 |
Type |
Journal Article |
|
Year |
2019 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
|
|
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
797 |
Issue |
|
Pages |
134809 - 6pp |
|
|
Keywords |
Nucleosynthesis; Neutron capture; Nuclear reactions; s-process; MACS; Neutron activation |
|
|
Abstract |
The Nd-Pm-Sm branching is of interest for the study of the s-process, related to the production of heavy elements in stars. As Sm-148 and Sm-150 are s-only isotopes, the understanding of the branching allows constraining the s-process neutron density. In this context the key physics input needed is the cross section of the three unstable nuclides in the region: Nd-147 (10.98 d half-life), Pm-147 (2.62 yr) and Pm-148 (5.37 d). This paper reports on the activation measurement of Pm-147, the longest-lived of the three nuclides. The cross section measurement has been carried out by activation at the SARAF LiLiT facility using a 56(2) μg target. Compared to the single previous measurement of Pm-147, the measurement presented herein benefits from a target 2000 times more massive. The resulting Maxwellian Averaged Cross Section (MACS) to the ground and metastable states in Pm-148 are 469(50) mb and 357(27) mb. These values are 41% higher (to the ground state) and 15% lower (to the metastable state) than the values reported so far, leading however to a total cross section of 826(107) mb consistent within uncertainties with the previous result and hence leaving unchanged the previous calculation of the s-process neutron density. |
|
|
Address |
[Guerrero, C.; Lerendegui-Marco, J.; Quesada, J. M.] Univ Seville, Seville, Spain, Email: cguerrero4@us.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0370-2693 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000488071200026 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
4161 |
|
Permanent link to this record |
|
|
|
|
Author |
n_TOF Collaboration (Alcayne, V. et al); Balibrea-Correa, J.; Domingo-Pardo, C.; Lerendegui-Marco, J.; Babiano-Suarez, V.; Ladarescu, I. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
A Segmented Total Energy Detector (sTED) optimized for (n,γ) cross-section measurements at n_TOF EAR2 |
Type |
Journal Article |
|
Year |
2024 |
Publication |
Radiation Physics and Chemistry |
Abbreviated Journal |
Radiat. Phys. Chem. |
|
|
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
217 |
Issue |
|
Pages |
11pp |
|
|
Keywords |
Neutron capture; PHWT; Scintillation detectors; Monte Carlo simulation |
|
|
Abstract |
The neutron time-of-flight facility nTOF at CERN is a spallation source dedicated to measurements of neutroninduced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of similar to 4 center dot 10(7) neutrons per nominal proton pulse, which is similar to 50 times higher than the one of Experimental ARea 1 (EAR1) of similar to 8 center dot 10(5) neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector's response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to gamma-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at nTOF EAR2. |
|
|
Address |
[Alcayne, V.; Cano-Ott, D.; Garcia, J.; Gonzalez-Romero, E.; Martinez, T.; de Rada, A. Perez; Plaza, J.; Sanchez-Caballero, A.; Mendoza, E.] Ctr Invest Energet Medioambient & Tecnol CIEMAT, Madrid, Spain, Email: victor.alcayne@ciemat.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Pergamon-Elsevier Science Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0969-806x |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:001185584800001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
5999 |
|
Permanent link to this record |
|
|
|
|
Author |
Balibrea-Correa, J.; Lerendegui-Marco, J.; Ladarescu, I.; Guerrero, C.; Rodriguez-Gonzalez, T.; Jimenez-Ramos, M.C.; Fernandez-Martinez, B.; Domingo-Pardo, C. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification |
Type |
Journal Article |
|
Year |
2022 |
Publication |
European Physical Journal Plus |
Abbreviated Journal |
Eur. Phys. J. Plus |
|
|
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
137 |
Issue |
11 |
Pages |
1258 - 18pp |
|
|
Keywords |
|
|
|
Abstract |
We report on a hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA cyclotron facility using a set of two synchronous Compton imagers and different target materials. The time structure of the 18 MeV proton beam was shaped with a series of beam-on and beam-off intervals, thereby mimicking a pulsed proton beam on a long time scale. During beam-on intervals, Compton imagingwas performed utilizing the high energy. -rays promptly emitted from the nuclear reactions occurring in the targets. In the course of the beam-off intervals in situ positron-emission tomography was accomplished with the same imagers using the beta+ decay of activated nuclei. The targets used were stacks of different materials covering also various proton ranges and energies. A systematic study on the performance of these two complementary imaging techniques is reported and the experimental results interpreted on the basis ofMonte Carlo calculations. The results demonstrate the possibility to combine both imaging techniques in a concomitant way, where high-efficiency prompt-gamma imaging is complemented with the high spatial accuracy of PET. Empowered by these results we suggest that a pulsed beam with a suitable duty cycle, in conjunction with in situ Compton- and PET-imaging may help to attain complementary information and quasi real-time range monitoring with high accuracy. |
|
|
Address |
[Balibrea-Correa, J.; Lerendegui-Marco, J.; Ladarescu, I; Domingo-Pardo, C.] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: javier.balibrea@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer Heidelberg |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2190-5444 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000886327900002 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
no |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
5420 |
|
Permanent link to this record |
|
|
|
|
Author |
n_TOF Collaboration (Lerendegui-Marco, J. et al.); Domingo-Pardo, C.; Tain, J.L.; Tarifeño-Saldivia, A. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Radiative neutron capture on Pu-242 in the resonance region at the CERN n_TOF-EAR1 facility |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Physical Review C |
Abbreviated Journal |
Phys. Rev. C |
|
|
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
97 |
Issue |
2 |
Pages |
024605 - 21pp |
|
|
Keywords |
|
|
|
Abstract |
The spent fuel of current nuclear reactors contains fissile plutonium isotopes that can be combined with uranium to make mixed oxide (MOX) fuel. In this way the Pu from spent fuel is used in a new reactor cycle, contributing to the long-term sustainability of nuclear energy. However, an extensive use of MOX fuels, in particular in fast reactors, requires more accurate capture and fission cross sections for some Pu isotopes. In the case of Pu-242 there are sizable discrepancies among the existing capture cross-section measurements included in the evaluations (all from the 1970s) resulting in an uncertainty as high as 35% in the fast energy region. Moreover, postirradiation experiments evaluated with JEFF-3.1 indicate an overestimation of 14% in the capture cross section in the fast neutron energy region. In this context, the Nuclear Energy Agency (NEA) requested an accuracy of 8% in this cross section in the energy region between 500 meV and 500 keV. This paper presents a new time-of-flight capture measurement on Pu-242 carried out at nTOF-EAR1 (CERN), focusing on the analysis and statistical properties of the resonance region, below 4 keV. The Pu-242(n, gamma) reaction on a sample containing 95(4) mg enriched to 99.959% was measured with an array of four C6D6 detectors and applying the total energy detection technique. The high neutron energy resolution of nTOF-EAR1 and the good statistics accumulated have allowed us to extend the resonance analysis up to 4 keV, obtaining new individual and average resonance parameters from a capture cross section featuring a systematic uncertainty of 5%, fulfilling the request of the NEA. |
|
|
Address |
[Lerendegui-Marco, J.; Guerrero, C.; Quesada, J. M.; Cortes-Giraldo, M. A.; Praena, J.; Sabate-Gilarte, M.] Univ Seville, Dept Fis Atom Mol & Nucl, E-41012 Seville, Spain, Email: cguerrero4@us.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2469-9985 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000424190700001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3474 |
|
Permanent link to this record |
|
|
|
|
Author |
n_TOF Collaboration (Domingo-Pardo, C. et al); Babiano-Suarez, V.; Balibrea-Correa, J.; Caballero, L.; Ladarescu, I.; Lerendegui-Marco, J.; Tain, J.L.; Tarifeño-Saldivia, A. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF |
Type |
Journal Article |
|
Year |
2023 |
Publication |
European Physical Journal A |
Abbreviated Journal |
Eur. Phys. J. A |
|
|
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
59 |
Issue |
1 |
Pages |
8 - 11pp |
|
|
Keywords |
|
|
|
Abstract |
This article presents a few selected developments and future ideas related to the measurement of (n, gamma ) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with gamma- ray imaging capability for background suppression, and the development of an array of small-volume organic scintilla tors aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area. |
|
|
Address |
[Domingo-Pardo, C.; Babiano-Suarez, V.; Balibrea-Correa, J.; Caballero, L.; Ladarescu, I.; Lerendegui-Marco, J.; Tain, J. L.; Tarifeno-Saldivia, A.] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: domingo@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1434-6001 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000926364900001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
5479 |
|
Permanent link to this record |