|
Lauritsen, T. et al, & Perez-Vidal, R. M. (2016). Characterization of a gamma-ray tracking array: A comparison of GRETINA and Gammasphere using a Co-60 source. Nucl. Instrum. Methods Phys. Res. A, 836, 46–56.
Abstract: In this paper; we provide a formalism for the characterization of tracking arrays with emphasis on the proper corrections required to extract their photopeak efficiencies and peak-to-total ratios. The methods are first applied to Gammasphere, a well characterized 4 pi array based on the principle of Compton suppression, and subsequently to GRETINA. The tracking efficiencies are then discussed and some guidelines as to what clustering angle to use in the tracking algorithm are presented. It was possible, using GEANT4 simulations, to scale the measured efficiencies up to the expected values for the full 4 pi implementation of GRETA.
|
|
|
Zago, L. et al, Gadea, A., & Algora, A. (2022). High-spin states in Po-212 above the alpha-decaying (18(+)) isomer. Phys. Lett. B, 834, 137457–5pp.
Abstract: The nucleus Po-212 has been produced through the fragmentation of a U-238 primary beam at 1GeV/nucleon at GSI, separated with the FRagment Separator, FRS, and studied via isomer gamma-decay spectroscopy with the RISING setup. Two delayed previously unknown gamma rays have been observed. One has been attributed to the E3 decay of a 21(-) isomeric state feeding the alpha-emitting 45-s (18(+)) high-spin isomer. The other gamma-ray line has been assigned to the decay of a higher-lying 23(+) metastable state. These are the first observations of high-spin states above the Po-212 (18(+)) isomer, by virtue of the selectivity obtained via ion-by-ion identification of U-238 fragmentation products. Comparison with shell-model calculations points to shortfalls in the nuclear interactions involving high- jproton and neutron orbitals, to which the region around Z similar to 100 is sensitive.
|
|
|
Liu, S., Bogard, F., Cornebise, P., Faus-Golfe, A., Fuster-Martinez, N., Griesmayer, E., et al. (2016). In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility. Nucl. Instrum. Methods Phys. Res. A, 832, 231–242.
Abstract: The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of similar to 10(6) has been successfully demonstrated and confirmed for the first time in simultaneous beam core (similar to 10(6) electrons) and beam halo (similar to 10(3) electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of diamond sensors using an a source, as well as using the electron beams at PHIL, a low energy (<5 MeV) photo-injector at LAL, and at ATF2. First beam halo measurement results using the DSv at ATF2 with different beam intensities and vacuum levels are also presented. Such measurements not only allow one to evaluate the different sources of beam halo generation but also to define the requirements for a suitable collimation system to be installed at ATF2, as well as to optimize its performance during future operation.
|
|
|
Calibbi, L., Perez, J. J., Masiero, A., Park, J. H., Porod, W., & Vives, O. (2010). FCNC and CP violation observables in an SU(3)-flavoured MSSM. Nucl. Phys. B, 831(1-2), 26–71.
Abstract: A non-Abelian flavour symmetry in a minimal supersymmetric standard model can explain the flavour structures in the Yukawa couplings and simultaneously solve the SUSY flavour problem. Similarly the SUSY CP problem can be solved if CP is spontaneously broken in the flavour sector. In this work, we present an explicit example of these statements with an SU(3) flavour symmetry and spontaneous CP violation. In addition, we show that it is still possible to find some significant deviation from the SM expectations as far as FCNC and CP violation are concerned. We find that large contributions can be expected in lepton flavour violating decays, as μ-> e gamma and tau -> μgamma, electric dipole moments, d(e) and d(n) and kaon CP violating processes as epsilon(K). We also show that without further modifications, it is unlikely for these models to solve the Phi(Bs) anomaly at low-moderate tan beta. Thus, these flavoured MSSM realizations are phenomenologically sensitive to the experimental searches in the realm of flavor and CP violation physics.
|
|
|
Hernandez-Prieto, A., Quintana, B., Martin, S., & Domingo-Pardo, C. (2016). Study of accuracy in the position determination with SALSA, a gamma-scanning system for the characterization of segmented HPGe detectors. Nucl. Instrum. Methods Phys. Res. A, 823, 98–106.
Abstract: Accurate characterization of the electric response of segmented high-purity germanium (HPGe) detectors as a function of the interaction position is one of the current goals of the Nuclear Physics community seeking to perform gamma-ray tracking or even imaging with these detectors. For this purpose, scanning devices must be developed to achieve the signal-position association with the highest precision. With a view to studying the accuracy achieved with SALSA, the SAlamanca Lyso-based Scanning Array, here we report a detailed study on the uncertainty sources and their effect in the position determination inside the HPGe detector to be scanned. The optimization performed on the design of SALSA, aimed at minimizing the effect of the uncertainty sources, afforded an intrinsic uncertainty of 2 mm for large coaxial detectors and 1 mm for planar ones.
|
|