|
Zhang, X., Chang, C., & Gimeno, B. (2019). Multipactor Analysis in Circular Waveguides Excited by TM01 Mode. IEEE Trans. Electron Devices, 66(11), 4943–4951.
Abstract: A series of detailed numerical simulations are used to investigate the properties ofmultipactor breakdown in circularwaveguidespropagating the TM01 mode. AMonte Carlo model is constructed to track the motion of the electrons, study the multipactor scenarios, and predict the multipactor thresholds. The theoretical and numerical analyses indicate that the product of the frequency and the gap (f . D) affects both the intensity of the ponderomotive force and its spatial distribution, which results from the nonuniformity of the radio frequency (RF) field and significantly influences the electrons' trajectoriesandmultipactor trends. The decrease in f . D results in a remarkable enhancement in the magnitude of the ponderomotive force, while the maximal intensity gradually moves toward the half radius R/2 area. Low values of f . D correspond to high ponderomotive potential, which sustains the short-range electrons and triggers the single-sidedmultipactor. In contrast, high values of f . D correspond to low ponderomotive potential, contributing to long-range electrons and exciting the double-sided multipactor. Fitting to the susceptibility diagram produces the border line and a modified f . D threshold of (f . D) th approximate to 338.4 GHz mm, which separates the susceptibility diagram into single-sided, double-sided, andmixed-sided zones. The initial electron energy influences their trajectories at high f . D and low RF power. This effect tends to dominate the multipactor behavior in the mixed-sided region.
|
|
|
Etxebeste, A., Barrio, J., Bernabeu, J., Lacasta, C., Llosa, G., Muñoz, E., et al. (2019). Study of sensitivity and resolution for full ring PET prototypes based on continuous crystals and analytical modeling of the light distribution. Phys. Med. Biol., 64(3), 035015–17pp.
Abstract: Sensitivity and spatial resolution are the main parameters to maximize in the performance of a PET scanner. For this purpose, detectors consisting of a combination of continuous crystals optically coupled to segmented photodetectors have been employed. With the use of continuous crystals the sensitivity is increased with respect to the pixelated crystals. In addition, spatial resolution is no longer limited to the crystal size. The main drawback is the difficulty in determining the interaction position. In this work, we present the characterization of the performance of a full ring based on cuboid continuous crystals coupled to SiPMs. To this end, we have employed the simulations developed in a previous work for our experimental detector head. Sensitivity could be further enhanced by using tapered crystals. This enhancement is obtained by increasing the solid angle coverage, reducing the wedge-shaped gaps between contiguous detectors. The performance of the scanners based on both crystal geometries was characterized following NEMA NU 4-2008 standardized protocol in order to compare them. An average sensitivity gain over the entire axial field of view of 13.63% has been obtained with tapered geometry while similar performance of the spatial resolution has been proven with both scanners. The activity at which NECR and true peak occur is smaller and the peak value is greater for tapered crystals than for cuboid crystals. Moreover, a higher degree of homogeneity was obtained in the sensitivity map due to the tighter packing of the crystals, which reduces the gaps and results in a better recovery of homogeneous regions than for the cuboid configuration. Some of the results obtained, such as spatial resolution, depend on the interaction position estimation and may vary if other method is employed.
|
|
|
Xie, J. J., Liang, W. H., & Oset, E. (2019). eta-He-4 interaction from the dd->eta He-4 reaction near threshold. Eur. Phys. J. A, 55(1), 6–8pp.
Abstract: .We analyze the data on the total cross sections for the dd4 He reaction close to threshold and look for possible 4 He bound states. We develop a framework in which the 4 He optical potential is the key ingredient, rather than parameterizing the scattering matrix, as is usually done. The strength of this potential, together with some production parameters, are fitted to the available experimental data. The relationship of the scattering matrix to the optical potential is established using the Bethe-Salpeter equation and the 4 He loop function incorporates the range of the interaction given by the experimental He-4 density. However, when we look for poles of the scattering matrix, we get poles in the bound region, poles in the positive energy region or no poles at all. If we further restrict the results with constraints from a theoretical model with all its uncertainties the bound states are not allowed. However, we find a bump structure in |T|2 of the 4 He 4 He scattering amplitude below threshold for the remaining solutions.
|
|
|
n_TOF Collaboration(Mastromarco, M. et al), Domingo-Pardo, C., & Tain, J. L. (2019). Cross section measurements of Gd-155,Gd-157(n,) induced by thermal and epithermal neutrons. Eur. Phys. J. A, 55(1), 9–20pp.
Abstract: Neutron capture cross section measurements on Gd-155 and Gd-157 were performed using the time-of-flight technique at the nTOF facility at CERN on isotopically enriched samples. The measurements were carried out in the nTOF experimental area EAR1, at 185 m from the neutron source, with an array of 4 C6D6 liquid scintillation detectors. At a neutron kinetic energy of 0.0253 eV, capture cross sections of 62.2(2.2) and 239.8(8.4) kilobarn have been derived for Gd-155 and Gd-157, respectively, with up to 6% deviation relative to values presently reported in nuclear data libraries, but consistent with those values within 1.6 standard deviations. A resonance shape analysis has been performed in the resolved resonance region up to 181 eV and 307 eV, respectively for Gd-155 and Gd-157, where on average, resonance parameters have been found in good agreement with evaluations. Above these energies and up to 1 keV, the observed resonance-like structure of the cross section has been analysed and characterised. From a statistical analysis of the observed neutron resonances we deduced: neutron strength function of 2.01(28)x10-4 and 2.17(41)x10-4; average total radiative width of 106.8(14) meV and 101.1(20) meV and s-wave resonance spacing 1.6(2) eV and 4.8(5) eV for n + Gd-155 and n + Gd-157 systems, respectively.
|
|
|
Dai, L. R., Pavao, R., Sakai, S., & Oset, E. (2019). tau(-) -> nu tau M1 M2, with M1, M2 pseudoscalar or vector mesons. Eur. Phys. J. A, 55(2), 20–22pp.
Abstract: .We perform a calculation of the -M1M2, with M1,M2 either pseudoscalar or vector mesons using the basic weak interaction and angular momentum algebra to relate the different processes. The formalism also leads to a different interpretation of the role played by G-parity in these decays. We also observe that, while PPp-wave production is compatible with chiral perturbation theory and experiment, VP and VVp-wave production is clearly incompatible with experiment and we develop the formalism also in this case, producing the VP or VV pairs in s-wave. We compare our results with experiment and other theoretical approaches for rates and invariant mass distributions and make predictions for unmeasured decays. We show the value of these reactions, particularly if the M1M2 mass distribution is measured, as a tool to learn about the meson-meson interaction and the nature of some resonances, coupling to two mesons, which are produced in such decays.
|
|
|
Dai, L. R., Wang, G. Y., Chen, X., Wang, E., Oset, E., & Li, D. M. (2019). The B+ -> J/phi omega K+ reaction and D*(D)over-bar* molecular states. Eur. Phys. J. A, 55(3), 36–7pp.
Abstract: We study the B+J/K+ reaction, and show that it is driven by the presence of two resonances, the X(3940) and X(3930), that are of molecular nature and couple most strongly to D*D*, but also to J/. Because of that, in the J/ mass distribution we find a peak related to the excitation of the resonances and a cusp with large strength at the D*D* threshold.
|
|
|
PANDA Collaboration(Barucca, G. et al), & Diaz, J. (2019). Precision resonance energy scans with the PANDA experiment at FAIR: Sensitivity study for width and line shape measurements of the X(3872). Eur. Phys. J. A, 55(3), 42–18pp.
Abstract: This paper summarises a comprehensive Monte Carlo simulation study for precision resonance energy scan measurements. Apart from the proof of principle for natural width and line shape measurements of very narrow resonances with PANDA, the achievable sensitivities are quantified for the concrete example of the charmonium-like X(3872) state discussed to be exotic, and for a larger parameter space of various assumed signal cross-sections, input widths and luminosity combinations. PANDA is the only experiment that will be able to perform precision resonance energy scans of such narrow states with quantum numbers of spin and parities that differ from JPC=1--.
|
|
|
Testov, D. et al, & Gadea, A. (2019). The 4pi highly-efficient light-charged-particle detector EUCLIDES, installed at the GALILEO array for in-beam gamma-ray spectroscopy. Eur. Phys. J. A, 55(4), 47–8pp.
Abstract: .In a fusion-evaporation reaction, nuclei are produced by evaporating light-charged particles and neutrons from the compound nucleus. Typically, a nucleus of interest is produced as a result of a part of the total cross-section and, in order to guarantee a good channel discrimination, a particle detector, like the EUCLIDES 4 Si-ball array, is necessary. EUCLIDES has been quoted in more than a hundred publications resulting from many experiments performed in combination with the EUROBALL and GASP -ray spectrometers. The present paper reports on the upgraded version of EUCLIDES, that is presently coupled to the new GALILEO -ray spectrometer, installed at the Laboratori Nazionali di Legnaro, INFN. The design, characteristics and performance of the EUCLIDES array are presented and discussed.
|
|
|
Lewandowski, L., Reiter, P., Birkenbach, B., Bruyneel, B., Clemente, E., Eberth, J., et al. (2019). Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors. Eur. Phys. J. A, 55(5), 81–13pp.
Abstract: The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a -ray source measurement based on e+e- annihilation radiation after decays of Na-22 by + decay. The first interaction positions of the two 511keV rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.
|
|
|
n_TOF Collaboration(Amaducci, S. et al), Domingo-Pardo, C., & Tain, J. L. (2019). Measurement of the U-235(n, f) cross section relative to the Li-6(n, t) and B-10(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF. Eur. Phys. J. A, 55(7), 120–19pp.
Abstract: .The U-235(n, f ) cross section was measured at n_TOF relative to Li-6(n, t) and B-10(n,alpha) , with high resolution ( L=183.49(2) m) and in a wide energy range (25meV-170keV) with 1.5% systematic uncertainty, making use of a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the yields of the U-235(n, f ) and of the two reference reactions under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10-30keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the cross section in the 9-18keV neutron energy range is indeed overestimated by almost 5% in the recently released evaluated data files ENDF/B-VIII.0 and JEFF3.3, as a consequence of a 7% overestimate in a single GMA node in the IAEA reference file. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The results here reported may lead to a reduction of the uncertainty in the 1-100keV neutron energy region. Finally, from the present data, a value of 249.7 +/- 1.4( stat )+/- 0.94( syst ) b<bold>eV has been extracted for the cross section integral between </bold>7.8 and 11eV, confirming the value of 247.5 +/- 3 b<bold>eV recently established as a standard</bold>.
|
|