n_TOF Collaboration(Lederer-Woods, C. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2019). Measurement of Ge-73(n, gamma) cross sections and implications for stellar nucleosynthesis. Phys. Lett. B, 790, 458–465.
Abstract: Ge-73(n, gamma) cross sections were measured at the neutron time-of-flight facility n_TOF at CERN up to neutron energies of 300 keV, providing for the first time experimental data above 8 keV. Results indicate that the stellar cross section at kT = 30 keV is 1.5 to 1.7 times higher than most theoretical predictions. The new cross sections result in a substantial decrease of Ge-73 produced in stars, which would explain the low isotopic abundance of Ge-73 in the solar system.
|
|
|
Tain, J. L., Agramunt, J., Algora, A., Aprahamian, A., Cano-Ott, D., Fraile, L. M., et al. (2015). The sensitivity of LaBr3:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation. Nucl. Instrum. Methods Phys. Res. A, 774, 17–24.
Abstract: The neutron sensitivity of a cylindrical circle minus 1.5 in x 1.5 in LaBr3:Ce scintillation detector was measured using quasi-monoenergetic neutron beams in the energy range from 40 keV to 2.5 MeV. In this energy range the detector is sensitive to gamma-rays generated in neutron inelastic and capture processes. The experimental energy response was compared with Monte Carlo simulations performed with the Geant4 simulation toolkit using the so-called High Precision Neutron Models. These models rely on relevant information stored in evaluated nuclear data libraries. The performance of the Geant4 Neutron Data Library as well as several standard nuclear data libraries was investigated. In the latter case this was made possible by the use of a conversion tool that allowed the direct use of the data from other libraries in Geant4. Overall it was found that there was good agreement with experiment for some of the neutron data bases like ENDF/B-VII.0 or JENDL-3.3 but not with the others such as ENDF/B-VI.8 or JEFF-3.1.
|
|
|
n_TOF Collaboration(Massimi, C. et al.), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2017). Neutron spectroscopy of Mg-26 states: Constraining the stellar neutron source Ne-22(alpha, n)Mg-25. Phys. Lett. B, 768, 1–6.
Abstract: This work reports on accurate, high-resolution measurements of the Mg-25(n, gamma)Mg-26 and Mg-25(n, tot) cross sections in the neutron energy range from thermal to about 300 keV, leading to a significantly improved Mg-25(n, gamma)Mg-26 parametrization. The relevant resonances for n+Mg-25 were characterized from a combined R-matrix analysis of the experimental data. This resulted in an unambiguous spin/parity assignment of the corresponding excited states in Mg-26. With this information experimental upper limits of the reaction rates for Ne-22(alpha, n)Mg-25 and Ne-22(alpha, gamma)Mg-26 were established, potentially leading to a significantly higher (alpha, n)/(alpha, gamma) ratio than previously evaluated. The impact of these results has been studied for stellar models in the mass range 2 to 25 M-circle dot. (C) 2017 The Author(s). Published by Elsevier B.V.
|
|
|
n_TOF Collaboration(Zugec, P. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2014). GEANT4 simulation of the neutron background of the C6D6 set-up for capture studies at n_TOF. Nucl. Instrum. Methods Phys. Res. A, 760, 57–67.
Abstract: The neutron sensitivity of the Cr6D6 detector setup used at nTOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire nTOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a(nat)-C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured C-nat yield has been discovered, which prevents the use of C-nat data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.
|
|
|
n_TOF Collaboration(Tarrio, D. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2014). Measurement of the angular distribution of fission fragments using a PPAC assembly at CERN n_TOF. Nucl. Instrum. Methods Phys. Res. A, 743, 79–85.
Abstract: A fission reaction chamber based on Parallel Plate Avalanche Counters (PPACs) was built for measuring angular distributions of fragments emitted in neutron-induced fission of actinides at the neutron beam available at the Neutron Time-Of-Flight (n_TOF) facility at CERN. The detectors and the samples were tilted 45 degrees with respect to the neutron beam direction to cover all the possible values of the emission angle of the fission fragments. The main features of this setup are discussed and results on the fission fragment angular distribution are provided for the Th-232(n,f) reaction around the fission threshold. The results are compared with the available data in the literature, demonstrating the good capabilities of this setup.
|
|