toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Guadilla, V. et al; Tain, J.L.; Algora, A.; Agramunt, J.; Jordan, D.; Monserrate, M.; Montaner-Piza, A.; Nacher, E.; Orrigo, S.E.A.; Rubio, B.; Valencia, E. url  doi
openurl 
  Title Total absorption gamma-ray spectroscopy of the beta-delayed neutron emitters I-137 and Rb-95 Type Journal Article
  Year 2019 Publication Physical Review C Abbreviated Journal Phys. Rev. C  
  Volume (down) 100 Issue 4 Pages 044305 - 17pp  
  Keywords  
  Abstract The decays of the beta-delayed neutron emitters( 137)I and Rb-95 have been studied with the total absorption gamma-ray spectroscopy technique. The purity of the beams provided by the JYFLTRAP Penning trap at the ion guide isotope separator on-line facility in Jyvaskyla allowed us to carry out a campaign of isotopically pure measurements with the decay total absorption gamma-ray spectrometer, a segmented detector composed of 18 NaI(T1) modules. The contamination coming from the interaction of neutrons with the spectrometer has been carefully studied, and we have tested the use of time differences between prompt gamma rays and delayed neutron interactions to eliminate this source of contamination. Due to the sensitivity of our spectrometer, we have found a significant amount of beta intensity to states above the neutron separation energy that deexcite by gamma rays, comparable to the neutron emission probability. The competition between gamma deexcitation and neutron emission has been compared with Hauser-Feshbach calculations, and it can be understood as a nuclear structure effect. In addition, we have studied the impact of the beta-intensity distributions determined in this work on reactor decay heat and reactor antineutrino spectrum summation calculations. The robustness of our results is demonstrated by a thorough study of uncertainties and with the reproduction of the spectra of the individual modules and the module-multiplicity gated spectra. This work represents the state-of-the-art of our analysis methodology for segmented total absorption spectrometers.  
  Address [Guadilla, V; Tain, J. L.; Algora, A.; Agramunt, J.; Jordan, D.; Monserrate, M.; Montaner-Piza, A.; Nacher, E.; Orrigo, S. E. A.; Rubio, B.; Valencia, E.] Univ Valencia, Inst Fis Corpuscular, CSIC, E-46071 Valencia, Spain, Email: guadilla@ific.uv.es  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2469-9985 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000489250100001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4169  
Permanent link to this record
 

 
Author Caballero-Folch, R. et al; Agramunt, J.; Tain, J.L.; Algora, A.; Domingo-Pardo, C.; Guadilla, V.; Montaner-Piza, A.; Orrigo, S.E.A.; Rubio, B.; Tarifeño-Saldivia, A.; Tolosa-Delgado, A. url  doi
openurl 
  Title First determination of beta-delayed multiple neutron emission beyond A=100 through direct neutron measurement: The P-2n value of Sb-136 Type Journal Article
  Year 2018 Publication Physical Review C Abbreviated Journal Phys. Rev. C  
  Volume (down) 98 Issue 3 Pages 034310 - 10pp  
  Keywords  
  Abstract Background: beta-delayed multiple neutron emission has been observed for some nuclei with A <= 100 being the Rb-100 the heaviest beta 2n emitter measured to date. So far only 25 P-2n values have been determined for the approximate to 300 nuclei that may decay in this way. Accordingly it is of interest to measure P-2n values for the other possible multiple neutron emitters throughout the chart of the nuclides. It is of particular interest to make such a measurement for nuclei with A > 100 to test the predictions of theoretical models and simulation tools for the decays of heavy nuclei in the region of very neutron-rich nuclei. In addition the decay properties of these nuclei are fundamental for the understanding of astrophysical nucleosynthesis processes such as the r-process and safety inputs for nuclear reactors. Purpose: To determine for the first time the two-neutron branching ratio the P-2n value for Sb-136 through a direct neutron measurement and to provide precise P-1n values for Sb-136 and Te-136. Method: A pure beam of each isotope of interest was provided by the JYFLTRAP Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility of the University of Jyvaskyla Finland. The purified ions were implanted into a moving tape at the end of the beam line. The detection setup consisted of a plastic scintillator placed right behind the implantation point after the tape to register the beta decays and the BELEN detector based on neutron counters embedded in a polyethylene matrix. The analysis was based on the study of the beta- and neutron-growth-and-decay curves and the beta-one-neutron and beta-two-neutron time correlations which allowed us the determination of the neutron branching ratios. Results: The P-2n value of Sb-136 was found to be 0.14(3)% and the measured P-1n values for Sb-136 and Te-136 were found to be 32.2(15)% and 1.47(6)% respectively. Conclusions: The measured P-2n value is a factor 44 smaller than predicted by the finite-range droplet model plus the quasiparticle random-phase approximation (FRDM+QRPA) model used for r-process calculations.  
  Address [Caballero-Folch, R.; Dillmann, I] TRIUMF, Vancouver, BC V6T 2A3, Canada, Email: rcaballero-folch@triumf.ca  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2469-9985 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000444207600003 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3728  
Permanent link to this record
 

 
Author Guadilla, V. et al; Algora, A.; Tain, J.L.; Agramunt, J.; Jordan, M.D.; Montaner-Piza, A.; Orrigo, S.E.A.; Rubio, B.; Valencia, E.; Gelletly, W.; Monserrate, M. url  doi
openurl 
  Title Experimental study of Tc-100 beta decay with total absorption gamma-ray spectroscopy Type Journal Article
  Year 2017 Publication Physical Review C Abbreviated Journal Phys. Rev. C  
  Volume (down) 96 Issue 1 Pages 014319 - 10pp  
  Keywords  
  Abstract The beta decay of Tc-100 has been studied by using the total absorption gamma-ray spectroscopy technique at the Ion Guide Isotope Separator On-Line facility in Jyvaskyla. In this work the new Decay Total Absorption gamma-ray Spectrometer in coincidence with a cylindrical plastic beta detector has been employed. The beta intensity to the ground state obtained from the analysis is in good agreement with previous high-resolution measurements. However, differences in the feeding to the first-excited state as well as weak feeding to a new level at high excitation energy have been deduced from this experiment. Theoretical calculations performed in the quasiparticle random-phase approximation framework are also reported. Comparison of these calculations with our measurement serves as a benchmark for calculations of the double beta decay of Mo-100.  
  Address [Guadilla, V.; Algora, A.; Tain, J. L.; Agramunt, J.; Jordan, D.; Montaner-Piza, A.; Orrigo, S. E. A.; Rubio, B.; Valencia, E.; Gelletly, W.; Monserrate, M.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46071 Valencia, Spain, Email: guadilla@ific.uv.es;  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2469-9985 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000406526600002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3225  
Permanent link to this record
 

 
Author XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A. url  doi
openurl 
  Title Search for two-neutrino double electron capture of Xe-124 with XENON100 Type Journal Article
  Year 2017 Publication Physical Review C Abbreviated Journal Phys. Rev. C  
  Volume (down) 95 Issue 2 Pages 024605 - 6pp  
  Keywords  
  Abstract Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For Xe-124 this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K shell of 124Xe using 7636 kg d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90% credibility limit on the half-life T-1/2 > 6.5 x 10(20) yr. We have also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and found a sensitivity of T-1/2 > 6.1 x 10(22) yr after an exposure of 2 t yr.  
  Address [Agostini, F.; Barrow, P.; Berger, T.; Butikofer, L.; Cardoso, J. M. R.; Di Gangi, P.; Diglio, S.; Franco, D.; Garbini, M.; Grignon, C.; Kaminsky, B.; Le Calloch, M.; Lopes, J. A. M.; Orrigo, S. E. A.; Sartorelli, G.; Schreiner, J.; Thers, D.; Zhang, Y.] Columbia Univ, Dept Phys, 538 W 120th St, New York, NY 10027 USA, Email: a.fieguth@uni-muenster.de;  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2469-9985 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000393744200001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2956  
Permanent link to this record
 

 
Author XENON Collaboration (Aprile, E. et al); Orrigo, S.E.A. url  doi
openurl 
  Title Results from a calibration of XENON100 using a source of dissolved radon-220 Type Journal Article
  Year 2017 Publication Physical Review D Abbreviated Journal Phys. Rev. D  
  Volume (down) 95 Issue 7 Pages 072008 - 10pp  
  Keywords  
  Abstract A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220-Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t(1/2) = (293.9 +/- (1.0)(stat) +/- (0.6)(sys)) ns.  
  Address [Aprile, E.; Anthony, M.; de Perio, P.; Gao, F.; Goetzke, L. W.; Greene, Z.; Lin, Q.; Messina, M.; Plante, G.; Rizzo, A.; Zhang, Y.] Columbia Univ, Dept Phys, New York, NY USA, Email: rafael@purdue.edu  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2470-0010 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000399945500001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3101  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva