Records |
Author |
Tortajada, S.; Albiol, F.; Caballero, L.; Albiol, A.; Leganes-Nieto, J.L. |
Title |
A portable geometry-independent tomographic system for gamma-ray, a next generation of nuclear waste characterization |
Type |
Journal Article |
Year |
2023 |
Publication |
Scientific Reports |
Abbreviated Journal |
Sci Rep |
Volume |
13 |
Issue |
1 |
Pages |
12284 - 10pp |
Keywords |
|
Abstract |
One of the main activities of the nuclear industry is the characterisation of radioactive waste based on the detection of gamma radiation. Large volumes of radioactive waste are classified according to their average activity, but often the radioactivity exceeds the maximum allowed by regulators in specific parts of the bulk. In addition, the detection of the radiation is currently based on static detection systems where the geometry of the bulk is fixed and well known. Furthermore, these systems are not portable and depend on the transport of waste to the places where the detection systems are located. However, there are situations where the geometry varies and where moving waste is complex. This is especially true in compromised situations.We present a new model for nuclear waste management based on a portable and geometry-independent tomographic system for three-dimensional image reconstruction for gamma radiation detection. The system relies on a combination of a gamma radiation camera and a visible camera that allows to visualise radioactivity using augmented reality and artificial computer vision techniques. This novel tomographic system has the potential to be a disruptive innovation in the nuclear industry for nuclear waste management. |
Address |
[Tortajada, Salvador; Albiol, Francisco; Caballero, Luis] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna Valencia, Spain, Email: s.tortajada@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Nature Portfolio |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2045-2322 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:001041587900052 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
no |
Call Number |
IFIC @ pastor @ |
Serial |
5612 |
Permanent link to this record |
|
|
|
Author |
Real, D.; Sanchez Losa, A.; Diaz, A.; Salesa Greus, F.; Calvo, D. |
Title |
The Neutrino Mediterranean Observatory Laser Beacon: Design and Qualification |
Type |
Journal Article |
Year |
2023 |
Publication |
Applied Sciences-Basel |
Abbreviated Journal |
Appl. Sci.-Basel |
Volume |
13 |
Issue |
17 |
Pages |
9935 - 16pp |
Keywords |
neutrino telescope; time calibration; laser beacon |
Abstract |
This paper encapsulates details of the NEMO laser beacon's design, offering a profound contribution to the field of the time calibration of underwater neutrino telescopes. The mechanical design of the laser beacon, which operates at a depth of 3500 m, is presented, together with the design of the antibiofouling system employed to endure the operational pressure and optimize the operational range, enhancing its functionality and enabling time calibration among multiple towers. A noteworthy innovation central to this development lies in the battery system. This configuration enhances the device's portability, a crucial aspect in underwater operations. The comprehensive design of the laser beacon, encompassing the container housing, the requisite battery system for operation, electronics, and an effective antibiofouling system, is described in this paper. Additionally, this paper presents the findings of the laser beacon's qualification process. |
Address |
[Real, Diego; Losa, Agustin Sanchez; Greus, Francisco Salesa; Calvo, David] CSIC Univ Valencia, IFIC Inst Fis Corpuscular, C Catedrat Jose Beltran 2, Paterna 46980, Spain, Email: real@ific.uv.es; |
Corporate Author |
|
Thesis |
|
Publisher |
Mdpi |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:001063704500001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
no |
Call Number |
IFIC @ pastor @ |
Serial |
5668 |
Permanent link to this record |
|
|
|
Author |
Baamara, Y.; Gessner, M.; Sinatra, A. |
Title |
Quantum-enhanced multiparameter estimation and compressed sensing of a field |
Type |
Journal Article |
Year |
2023 |
Publication |
Scipost Physics |
Abbreviated Journal |
SciPost Phys. |
Volume |
14 |
Issue |
3 |
Pages |
050 - 18pp |
Keywords |
|
Abstract |
We show that a significant quantum gain corresponding to squeezed or over-squeezed spin states can be obtained in multiparameter estimation by measuring the Hadamard coefficients of a 1D or 2D signal. The physical platform we consider consists of twolevel atoms in an optical lattice in a squeezed-Mott configuration, or more generally by correlated spins distributed in spatially separated modes. Our protocol requires the possibility to locally flip the spins, but relies on collective measurements. We give examples of applications to scalar or vector field mapping and compressed sensing. |
Address |
[Baamara, Youcef; Sinatra, Alice] Univ PSL, Univ Sorbonne, ENS, Lab Kastler Brossel,CNRS, 24 Rue Lhomond, F-75231 Paris, France, Email: alice.sinatra@lkb.ens.fr |
Corporate Author |
|
Thesis |
|
Publisher |
Scipost Foundation |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2542-4653 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000974981200008 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
5519 |
Permanent link to this record |
|
|
|
Author |
Fougeres, C. et al; Domingo-Pardo, C. |
Title |
Search for Na-22 in novae supported by a novel method for measuring femtosecond nuclear lifetimes |
Type |
Journal Article |
Year |
2023 |
Publication |
Nature Communications |
Abbreviated Journal |
Nat. Commun. |
Volume |
14 |
Issue |
1 |
Pages |
4536 - 7pp |
Keywords |
|
Abstract |
Classical novae are thermonuclear explosions in stellar binary systems, and important sources of Al-26 and Na-22. While ? rays from the decay of the former radioisotope have been observed throughout the Galaxy, Na-22 remains untraceable. Its half-life (2.6 yr) would allow the observation of its 1.275 MeV ?-ray line from a cosmic source. However, the prediction of such an observation requires good knowledge of its nucleosynthesis. The Na-22(p, ?)Mg-23 reaction remains the only source of large uncertainty about the amount of Na-22 ejected. Its rate is dominated by a single resonance on the short-lived state at 7785.0(7) keV in Mg-23. Here, we propose a combined analysis of particle-particle correlations and velocity-difference profiles to measure femtosecond nuclear lifetimes. The application of this method to the study of the Mg-23 states, places strong limits on the amount of Na-22 produced in novae and constrains its detectability with future space-borne observatories. The authors report a particle-particle correlation and velocity-difference profile method to measure nuclear lifetime. The results obtained for excited states of 23Mg are used to constrain the production of 22Na in the astrophysical novae explosions. |
Address |
[Fougeres, Chloe; Santos, Francois de Oliveira; Michelagnoli, Caterina; Clement, Emmanuel; Kim, Yung Hee; Lemasson, Antoine; Boulay, Florent; Goupil, Johan; Li, Hongjie; Navin, Alahari; Ralet, Damien; Saillant, Frederic] Grand Accelerateur Natl Ions Lourds GANIL, CEA, IN2P3, DRF CNRS, Caen, France, Email: chloe.fougeres@gmail.com; |
Corporate Author |
|
Thesis |
|
Publisher |
Nature Portfolio |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:001063751200012 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
5671 |
Permanent link to this record |
|
|
|
Author |
Oliver-Canamas, L.; Vijande, J.; Candela-Juan, C.; Gimeno-Olmos, J.; Pujades-Claumarchirant, M.C.; Rovira-Escutia, J.J.; Ballester, F.; Perez-Calatayud, J. |
Title |
A User-Friendly System for Mailed Dosimetric Audits of Ir-192 or Co-60 HDR Brachytherapy Sources |
Type |
Journal Article |
Year |
2023 |
Publication |
Cancers |
Abbreviated Journal |
Cancers |
Volume |
15 |
Issue |
9 |
Pages |
2484 - 14pp |
Keywords |
high dose rate brachytherapy; dosimetric audit; error detection; phantom |
Abstract |
Nowadays, the options available to perform external dosimetric audits of the high dose rate (HDR) brachytherapy treatment process are limited. In this work, we present a methodology that allows for performing dosimetric audits in this field. A phantom was designed and manufactured for this purpose. The criteria for its design, together with the in-house measurements for its characterization, are presented. The result is a user-friendly system that can be mailed to perform dosimetric audits in HDR brachytherapy on-site for systems using either Iridium-192 (Ir-192) or Cobalt-60 (Co-60) sources. Objectives: The main goal of this work is to design and characterize a user-friendly methodology to perform mailed dosimetric audits in high dose rate (HDR) brachytherapy for systems using either Iridium-192 (Ir-192) or Cobalt-60 (Co-60) sources. Methods: A solid phantom was designed and manufactured with four catheters and a central slot to place one dosimeter. Irradiations with an Elekta MicroSelectron V2 for Ir-192, and with a BEBIG Multisource for Co-60 were performed for its characterization. For the dose measurements, nanoDots, a type of optically stimulated luminescent dosimeters (OSLDs), were characterized. Monte Carlo (MC) simulations were performed to evaluate the scatter conditions of the irradiation set-up and to study differences in the photon spectra of different Ir-192 sources (Microselectron V2, Flexisource, BEBIG Ir2.A85-2 and Varisource VS2000) reaching the dosimeter in the irradiation set-up. Results: MC simulations indicate that the surface material on which the phantom is supported during the irradiations does not affect the absorbed dose in the nanoDot. Generally, differences below 5% were found in the photon spectra reaching the detector when comparing the Microselectron V2, the Flexisource and the BEBIG models. However, differences up to 20% are observed between the V2 and the Varisource VS2000 models. The calibration coefficients and the uncertainty in the dose measurement were evaluated. Conclusions: The system described here is able to perform dosimetric audits in HDR brachytherapy for systems using either Ir-192 or Co-60 sources. No significant differences are observed between the photon spectra reaching the detector for the MicroSelectron V2, the Flexisource and the BEBIG Ir-192 sources. For the Varisource VS2000, a higher uncertainty is considered in the dose measurement to allow for the nanoDot response. |
Address |
[Oliver-Canamas, Laura] Serv Radiofis & Proteccio Radiol, Consorci Hospitalari Prov Castello CHPC, Castellon de La Plana 12002, Spain, Email: laura.oliver.canas@gmail.com |
Corporate Author |
|
Thesis |
|
Publisher |
Mdpi |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000987247100001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
no |
Call Number |
IFIC @ pastor @ |
Serial |
5542 |
Permanent link to this record |