Modamio, V., Valiente-Dobon, J. J., Jaworski, G., Huyuk, T., Triossi, A., Egea, J., et al. (2015). Digital pulse-timing technique for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 775, 71–76.
Abstract: A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
|
Bayar, M., & Debastiani, V. R. (2017). a(0)(980) – f(0)(980) mixing in chi(c1) -> pi(0)f(0)(980) -> pi(0)pi(+)pi(-) and chi(c1) -> pi(0) a(0)(980) -> pi(0)pi(0)eta. Phys. Lett. B, 775, 94–99.
Abstract: We study the isospin breaking in the reactions chi(c1) -> pi(0)pi(+)pi(-) and chi(c1) -> pi(0)pi(0)eta and its relation to the a(0)(980) – f(0)(980) mixing, which was measured by the BESIII Collaboration. We show that the same theoretical model previously developed to study the chi(c1) -> eta pi(+)pi(-) reaction (also measured by BESIII), and further explored in the predictions to the eta(c) -> eta pi(+)pi(-), can be successfully employed in the present study. We assume that the chi(c1) behaves as an SU(3) singlet to find the weight in which trios of pseudoscalars are created, followed by the final state interaction of pairs of mesons to describe how the a(0)(980) and f(0)(980) are dynamically generated, using the chiral unitary approach in coupled channels. The isospin violation is introduced through the use of different masses for the charged and neutral kaons, either in the propagators of pairs of mesons created in the chi(c1) decay, or in the propagators inside the T matrix, constructed through the unitarization of the scattering and transition amplitudes of pairs of pseudoscalar mesons. We find that violating isospin inside the T matrix makes the pi(0)eta -> pi(+)pi(-) amplitude nonzero, which gives an important contribution and also enhances the effect of the K (K) over bar term. We also find that the most important effect in the total amplitude is the isospin breaking inside the T matrix, due to the constructive sum of pi(0)eta -> pi(+)pi(-) and K (K) over bar -> pi(+)pi(-), which is essential to get a good agreement with the experimental measurement of the mixing.
|
ANTARES Collaboration(Adrian-Martinez, S. et al), Bigongiari, C., Emanuele, U., Gomez-Gonzalez, J. P., Hernandez-Rey, J. J., Lambard, G., et al. (2013). Search for a correlation between ANTARES neutrinos and Pierre Auger Observatory UHECRs arrival directions. Astrophys. J., 774(1), 19–7pp.
Abstract: A multimessenger analysis optimized for a correlation of arrival directions of ultra-high energy cosmic rays (UHECRs) and neutrinos is presented and applied to 2190 neutrino candidate events detected in 2007-2008 by the ANTARES telescope and 69 UHECRs observed by the Pierre Auger Observatory between 2004 January 1 and 2009 December 31. No significant correlation is observed. Assuming an equal neutrino flux (E-2 energy spectrum) from all UHECR directions, a 90% CL upper limit on the neutrino flux of 5.0 x 10(-8) GeV cm(-2) s(-1) per source is derived.
|
Tain, J. L., Agramunt, J., Algora, A., Aprahamian, A., Cano-Ott, D., Fraile, L. M., et al. (2015). The sensitivity of LaBr3:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation. Nucl. Instrum. Methods Phys. Res. A, 774, 17–24.
Abstract: The neutron sensitivity of a cylindrical circle minus 1.5 in x 1.5 in LaBr3:Ce scintillation detector was measured using quasi-monoenergetic neutron beams in the energy range from 40 keV to 2.5 MeV. In this energy range the detector is sensitive to gamma-rays generated in neutron inelastic and capture processes. The experimental energy response was compared with Monte Carlo simulations performed with the Geant4 simulation toolkit using the so-called High Precision Neutron Models. These models rely on relevant information stored in evaluated nuclear data libraries. The performance of the Geant4 Neutron Data Library as well as several standard nuclear data libraries was investigated. In the latter case this was made possible by the use of a conversion tool that allowed the direct use of the data from other libraries in Geant4. Overall it was found that there was good agreement with experiment for some of the neutron data bases like ENDF/B-VII.0 or JENDL-3.3 but not with the others such as ENDF/B-VI.8 or JEFF-3.1.
|
NEXT Collaboration(Henriques, C. A. O. et al), Gomez-Cadenas, J. J., Alvarez, V., Benlloch-Rodriguez, J., Botas, A., Carcel, S., et al. (2017). Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection. Phys. Lett. B, 773, 663–671.
Abstract: Xe-CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05-0.1% can reduce significantly the scale of electron diffusion from 10 mm/root m to 2.5 mm/root m, with high impact on the discrimination of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe-CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2.
|