Testov, D. et al, & Gadea, A. (2019). The 4pi highly-efficient light-charged-particle detector EUCLIDES, installed at the GALILEO array for in-beam gamma-ray spectroscopy. Eur. Phys. J. A, 55(4), 47–8pp.
Abstract: .In a fusion-evaporation reaction, nuclei are produced by evaporating light-charged particles and neutrons from the compound nucleus. Typically, a nucleus of interest is produced as a result of a part of the total cross-section and, in order to guarantee a good channel discrimination, a particle detector, like the EUCLIDES 4 Si-ball array, is necessary. EUCLIDES has been quoted in more than a hundred publications resulting from many experiments performed in combination with the EUROBALL and GASP -ray spectrometers. The present paper reports on the upgraded version of EUCLIDES, that is presently coupled to the new GALILEO -ray spectrometer, installed at the Laboratori Nazionali di Legnaro, INFN. The design, characteristics and performance of the EUCLIDES array are presented and discussed.
|
Ertoprak, A. et al, Algora, A., Gadea, A., & Huyuk, T. (2018). M1 and E2 transition rates from core-excited states in semi-magic Ru-94. Eur. Phys. J. A, 54(9), 145–9pp.
Abstract: Lifetimes of high-spin states have been measured in the semi-magic (N = 50) nucleus Ru-94. Excited states in Ru-94 were populated in the Ni-58(Ca-40, 4p)Ru-94* fusion-evaporation reaction at the Grand Accelerateur National d'Ions Lourds (GANIL) accelerator complex. DSAM lifetime analysis was performed on the Doppler broadened line shapes in energy spectra obtained from gamma-rays emitted while the residual nuclei were slowing down in a thick 6 mg/cm(2) metallic Ni-58 target. In total eight excited-state lifetimes in the angular momentum range I = (13-20)h have been measured, five of which were determined for the first time. The corresponding B(M1) and B(E2) reduced transition strengths are discussed within the framework of large-scale shell model calculations to study the contribution of different particle-hole configurations, in particular for analyzing contributions from core-excited configurations.
|
Colovic, P. et al, & Gadea, A. (2017). Stretched configuration of states as inferred from gamma-ray angular distributions in Ar-40+Pb-208 neutron transfer reactions. Eur. Phys. J. A, 53(8), 166–6pp.
Abstract: Angular distributions of.-rays for selected transitions in Ar-40,Ar-41,Ar-42 isotopes have been studied with the PRISMA magnetic spectrometer coupled to the CLARA gamma array. These transitions were populated in Ar isotopes reached via neutron transfer in the Ar-40 + Pb-208 reaction. By comparison with the shape of the experimental angular distribution of the known E2 transitions we established more firmly the spin and parity of excited states. In particular, in Ar-41 for the (11/2(-)) state through the (11/2(-)) -> 7/2(-) transition whose structure was discussed in terms of a phonon-fermion coupled state. The comparison with the expected fully aligned spin indicated that a high level of spin alignment has been reached.
|
Doncel, M., Gadea, A., Valiente-Dobon, J. J., Quintana, B., Modamio, V., Mengoni, D., et al. (2017). Determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method in combination with magnetic spectrometers. Eur. Phys. J. A, 53(10), 211–5pp.
Abstract: The current work presents the determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method, in combination with spectrometers for ion identification, normalizing the intensity of the peaks by the ions detected in the spectrometer as a valid technique that produces results comparable to the ones obtained by the conventional shifted-to-unsifted peak ratio method. The technique has been validated using data measured with the gamma-ray array AGATA, the PRISMA spectrometer and the Cologne plunger setup. In this paper a test performed with the AGATA-PRISMA setup at LNL and the advantages of this new approach with respect to the conventional Recoil Distance Doppler Shift Method are discussed.
|
Huyuk, T. et al, Gadea, A., Aliaga-Varea, R. J., & Domingo-Pardo, C. (2016). Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA. Eur. Phys. J. A, 52(3), 55–8pp.
Abstract: The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large gamma-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23 l and it is filled with the EJ301 liquid scintillator, that presents good neutron-gamma discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the Ni-58 + Fe-56 reaction measured with the Neutron Wall detector array.
|