n_TOF Collaboration(Lederer-Woods, C. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2019). Measurement of Ge-73(n, gamma) cross sections and implications for stellar nucleosynthesis. Phys. Lett. B, 790, 458–465.
Abstract: Ge-73(n, gamma) cross sections were measured at the neutron time-of-flight facility n_TOF at CERN up to neutron energies of 300 keV, providing for the first time experimental data above 8 keV. Results indicate that the stellar cross section at kT = 30 keV is 1.5 to 1.7 times higher than most theoretical predictions. The new cross sections result in a substantial decrease of Ge-73 produced in stars, which would explain the low isotopic abundance of Ge-73 in the solar system.
|
ATLAS Collaboration(Aaboud, M. et al), Alvarez Piqueras, D., Aparisi Pozo, J. A., Bailey, A. J., Barranco Navarro, L., Cabrera Urban, S., et al. (2019). Study of the hard double-parton scattering contribution to inclusive four-lepton production in pp collisions at root s=8 TeV with the ATLAS detector. Phys. Lett. B, 790, 595–614.
Abstract: The inclusive production of four isolated charged leptons in pp collisions is analysed for the presence of hard double-parton scattering, using 20.2 fb(-1) of data recorded in the ATLAS detector at the LHC at centre-of-mass energy root s = 8 TeV. In the four-lepton invariant-mass range of 80 < m(4l) < 1000 GeV, an artificial neural network is used to enhance the separation between single- and double-parton scattering based on the kinematics of the four leptons in the final state. An upper limit on the fraction of events originating from double-parton scattering is determined at 95% confidence level to be f(DPS) = 0.042, which results in an estimated lower limit on the effective cross section at 95% confidence level of 1.0 mb.
|
Ellis, J., Mavromatos, N. E., Sakharov, A. S., & Sarkisyan-Grinbaum, E. K. (2019). Limits on neutrino Lorentz violation from multimessenger observations of TXS 0506+056. Phys. Lett. B, 789, 352–355.
Abstract: The observation by the IceCube Collaboration of a high-energy (E greater than or similar to 200 TeV) neutrino from the direction of the blazar TXS 0506+056 and the coincident observations of enhanced gamma-ray emissions from the same object by MAGIC and other experiments can be used to set stringent constraints on Lorentz violation in the propagation of neutrinos that is linear in the neutrino energy: Delta v = -E/M-1, where Delta v is the deviation from the velocity of light, and M-1 is an unknown high energy scale to be constrained by experiment. Allowing for a difference in neutrino and photon propagation times of similar to 10 days, we find that M-1 greater than or similar to 3 x 10(16) GeV. This improves on previous limits on linear Lorentz violation in neutrino propagation by many orders of magnitude, and the same is true for quadratic Lorentz violation.
|
de Salas, P. F., Pastor, S., Ternes, C. A., Thakore, T., & Tortola, M. (2019). Constraining the invisible neutrino decay with KM3NeT-ORCA. Phys. Lett. B, 789, 472–479.
Abstract: Several theories of particle physics beyond the Standard Model consider that neutrinos can decay. In this work we assume that the standard mechanism of neutrino oscillations is altered by the decay of the heaviest neutrino mass state into a sterile neutrino and, depending on the model, a scalar or a Majoron. We study the sensitivity of the forthcoming KM3NeT-ORCA experiment to this scenario and find that it could improve the current bounds coming from oscillation experiments, where three-neutrino oscillations have been considered, by roughly two orders of magnitude. We also study how the presence of this neutrino decay can affect the determination of the atmospheric oscillation parameters sin(2) theta(23) and Delta m(31)(2), as well as the sensitivity to the neutrino mass ordering.
|
Grkovski, M., Brzezinski, K., Cindro, V., Clinthorne, N. H., Kagan, H., Lacasta, C., et al. (2015). Evaluation of a high resolution silicon PET insert module. Nucl. Instrum. Methods Phys. Res. A, 788, 86–94.
Abstract: Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm(2) pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (20) geometry with a Jaszczak phantom (rod diameters of 12-4.8 mm) Filled with F-18-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).
|