|
Grkovski, M., Brzezinski, K., Cindro, V., Clinthorne, N. H., Kagan, H., Lacasta, C., et al. (2015). Evaluation of a high resolution silicon PET insert module. Nucl. Instrum. Methods Phys. Res. A, 788, 86–94.
Abstract: Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm(2) pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (20) geometry with a Jaszczak phantom (rod diameters of 12-4.8 mm) Filled with F-18-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).
|
|
|
Llosa, G. (2015). Recent developments in photodetection for medical applications. Nucl. Instrum. Methods Phys. Res. A, 787, 353–357.
Abstract: The use of the most advanced technology in medical imaging results in the development of high performance detectors that can significantly improve the performance of the medical devices employed in hospitals. Scintillator crystals coupled to photodetectors remain to be essential detectors in terms of performance and cost for medical imaging applications in different imaging modalities. Recent advances in photodetectors result in an increase of the performance of the medical scanners. Solid state detectors can provide substantial performance improvement, but are more complex to integrate into clinical detectors due mainly to their higher cost. Solid state photodetectors (APDs, SiPMs) have made new detector concepts possible and have led to improvements in different imaging modalities. Recent advances in detectors for medical imaging are revised.
|
|
|
PreSPEC and AGATA Collaborations(Ralet, D. et al), & Gadea, A. (2015). Data-flow coupling and data-acquisition triggers for the PreSPEC-AGATA campaign at GSI. Nucl. Instrum. Methods Phys. Res. A, 786, 32–39.
Abstract: The PreSPEC setup for high-resolution 'gamma-ray spectroscopy using radioactive ion beams was employed for experimental campaigns in 2012 and 2014. The setup consisted of the state of the art Advanced GAmma Tracking Array (AGATA) and the High Energy gamma cleteCTOR (HECTOR+) positioned around a secondary target at the final focal plane of the GSI FRagment Separator (FRS) to perform in-beam gamma-ray spectroscopy of exotic nuclei. The Lund York Cologne CAlorimeter (LYCCA) was used to identify the reaction products. In this paper we report on the trigger scheme used during the campaigns. The dataflow coupling between the Multi-Branch System (MBS) based Data AcQuisition (DAQ) used for FRS-LYCCA and the “Nouvelle Acquisition temps Reel Version 1.2 Avec Linux” (NARVAL) based acquisition system used for AGATA are also described.
|
|
|
Modamio, V., Valiente-Dobon, J. J., Jaworski, G., Huyuk, T., Triossi, A., Egea, J., et al. (2015). Digital pulse-timing technique for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 775, 71–76.
Abstract: A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
|
|
|
Tain, J. L., Agramunt, J., Algora, A., Aprahamian, A., Cano-Ott, D., Fraile, L. M., et al. (2015). The sensitivity of LaBr3:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation. Nucl. Instrum. Methods Phys. Res. A, 774, 17–24.
Abstract: The neutron sensitivity of a cylindrical circle minus 1.5 in x 1.5 in LaBr3:Ce scintillation detector was measured using quasi-monoenergetic neutron beams in the energy range from 40 keV to 2.5 MeV. In this energy range the detector is sensitive to gamma-rays generated in neutron inelastic and capture processes. The experimental energy response was compared with Monte Carlo simulations performed with the Geant4 simulation toolkit using the so-called High Precision Neutron Models. These models rely on relevant information stored in evaluated nuclear data libraries. The performance of the Geant4 Neutron Data Library as well as several standard nuclear data libraries was investigated. In the latter case this was made possible by the use of a conversion tool that allowed the direct use of the data from other libraries in Geant4. Overall it was found that there was good agreement with experiment for some of the neutron data bases like ENDF/B-VII.0 or JENDL-3.3 but not with the others such as ENDF/B-VI.8 or JEFF-3.1.
|
|
|
ATLAS Collaboration(Aad, G. et al), Alvarez Piqueras, D., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., et al. (2015). Measurement of the branching ratio Gamma(Lambda(0)(b) -> Psi(2S)Lambda(0))/ Gamma(Lambda(0.)(b) -> J/Psi Lambda(0)) with the ATLAS detector. Phys. Lett. B, 751, 63–80.
Abstract: An observation of the Lambda(0)(b) -> Psi (2S) Lambda(0) decay and a comparison of its branching fraction with that of the Lambda(0)(b) -> Psi (2S) Lambda(0) decay has been made with the ATLAS detector in proton-proton collisions at root s = 8 TeVat the LHC using an integrated luminosity of 20.6fb(-1). The J/Psi and Psi(2S) mesons are reconstructed in their decays to a muon pair, while the Lambda(0) -> p pi(-) decay is exploited for the Lambda(0) 0baryon reconstruction. The Lambda(0)(b) baryons are reconstructed with transverse momentum p(T)> 10 GeVand pseudorapidity vertical bar eta vertical bar < 2.1. The measured branching ratio of the Lambda(0)(b) -> Psi (2S) Lambda(0) and Lambda(0)(b) -> Psi (2S) Lambda(0) decays is Gamma(Lambda(0)(b) -> Psi (2S) Lambda(0)) / Gamma(Lambda(0)(b) -> Psi (2S) Lambda(0)) = 0.501 +/- 0.033(stat) +/- 0.019(syst), lower than the expectation from the covariant quark model.
|
|
|
Ruiz-Femenia, P., & Zahiri-Abyaneh, M. (2015). On the minimality of the order p(6) chiral Lagrangian. Phys. Lett. B, 751, 256–261.
Abstract: A method to find relations between the operators in the mesonic Lagrangian of Chiral Perturbation Theory at order p(6) is presented. The procedure can be used to establish if the basis of operators in the Lagrangian is minimal. As an example, we apply the method to the two-flavor case in the absence of scalar and pseudo-scalar sources (s = p = 0), and conclude that the minimal Lagrangian contains 27 independent operators.
|
|
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Ferrer, A., Fiorini, L., et al. (2015). Measurement of the production of neighbouring jets in lead-lead collisions at root s(NN)=2.76TeV with the ATLAS detector. Phys. Lett. B, 751, 376–395.
Abstract: This Letter presents measurements of correlated production of nearby jets in Pb+Pb collisions at root s(NN) = 2.76 TeV using the ATLAS detector at the Large Hadron Collider. The measurement was performed using 0.14 nb(-1)of data recorded in 2011. The production of correlated jet pairs was quantified using the rate, R-Delta R, of “neighbouring” jets that accompany “test” jets within a given range of angular distance, Delta R, in the pseudorapidity-azimuthal angle plane. The jets were measured in the ATLAS calorimeter and were reconstructed using the anti-ktalgorithm with radius parameters d = 0.2, 0.3, and 0.4. R-Delta R was measured in different Pb+Pbcollision centrality bins, characterized by the total transverse energy measured in the forward calorimeters. Acentrality dependence of R-Delta R is observed for all three jet radii with R-Delta R found to be lower in central collisions than in peripheral collisions. The ratios formed by the R-Delta R values in different centrality bins and the values in the 40-80% centrality bin are presented.
|
|
|
Boronat, M., Fuster, J., Garcia, I., Ros, E., & Vos, M. (2015). A robust jet reconstruction algorithm for high-energy lepton colliders. Phys. Lett. B, 750, 95–99.
Abstract: We propose a new sequential jet reconstruction algorithm for future lepton colliders at the energy frontier. The Valencia algorithm combines the natural distance criterion for lepton colliders with the greater robustness against backgrounds of algorithms adapted to hadron colliders. Results on a detailed Monte Carlo simulation of t (t) over tilde and ZZ production at future linear e(+)e(-) colliders (ILC and CLIC) with a realistic level of background overlaid, show that it achieves better performance in the presence of background than the classical algorithms used at previous e(+)e(-) colliders.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2015). Study of the quasi-free np -> np pi(+)pi(-) reaction with a deuterium beam at 1.25 GeV/nucleon. Phys. Lett. B, 750, 184–193.
Abstract: The tagged quasi-free np -> np pi(+)pi(-) reaction has been studied experimentally with the High Acceptance Di-Electron Spectrometer (HADES) at GSI at a deuteron incident beam energy of 1.25 GeV/nucleon (root S similar to 2.42 GeV/c for the quasi-free collision). For the first time, differential distributions of solid statistics for pi(+)pi(-) production in np collisions have been collected in the region corresponding to the large transverse momenta of the secondary particles. The invariant mass and angular distributions for the np -> np pi(+)pi(-) reaction are compared with different models. This comparison confirms the dominance of the t-channel with Delta Delta contribution. It also validates the changes previously introduced in the Valencia model to describe two-pion production data in other isospin channels, although some deviations are observed, especially for the pi(+)pi(-) invariant mass spectrum. The extracted total cross section is also in much better agreement with this model. Our new measurement puts useful constraints for the existence of the conjectured dibaryon resonance at mass M similar to 2.38 GeV and with width Gamma similar to 70 MeV. (C) 2015 The Authors. Published by Elsevier B.V.
|
|