Sun, B. X., Chen, H. X., & Oset, E. (2011). rho rho N and rho rho Delta molecules with J(P)=5/2(+) and J(P)=7/2(+). Eur. Phys. J. A, 47(10), 127–8pp.
Abstract: The rho rho N and rho rho Delta three-body systems have been studied within the framework of the fixed center approximation of Faddeev equation. The rho rho interaction in isospin I = 0, spin S = 2 is strongly attractive, and so are the N rho, Delta rho interactions. This leads to bound states of both rho rho N and rho rho Delta. We find peaks of the modulus squared of the scattering matrix around 2227 MeV for rho rho N, and 2372 MeV for rho rho Delta. Yet, the strength of the peak for the rho rho N amplitude is much smaller than for rho rho Delta, weakening the case for a rho rho N bound state, or a dominant rho rho N component. A discussion is made on how these states can be searched for in present programs looking for multimeson final states in different reactions.
|
n_TOF Collaboration(Belloni, F. et al), Domingo-Pardo, C., & Tain, J. L. (2011). Measurement of the neutron-induced fission cross-section of Am-243 relative to U-235 from 0.5 to 20 MeV. Eur. Phys. J. A, 47(12), 160–8pp.
Abstract: The ratio of the neutron-induced fission cross-sections of Am-243 and U-235 was measured in the energy range from 0.5 to 20 MeV with uncertainties of approximate to 4%. The experiment was performed at the CERN n_TOF facility using a fast ionization chamber. With the good counting statistics that could be achieved thanks to the high instantaneous flux and the low backgrounds, the present results are useful for resolving discrepancies in previous data sets and are important for future reactors with improved fuel burn-up.
|
Doring, M., Meissner, U. G., Oset, E., & Rusetsky, A. (2011). Unitarized Chiral Perturbation Theory in a finite volume: Scalar meson sector. Eur. Phys. J. A, 47(11), 139–15pp.
Abstract: We develop a scheme for the extraction of the properties of the scalar mesons f(0)(600), f(0)(980), and a(0)(980) from lattice QCD data. This scheme is based on a two-channel chiral unitary approach with fully relativistic propagators in a finite volume. In order to discuss the feasibility of finding the mass and width of the scalar resonances, we analyze synthetic lattice data with a fixed error assigned, and show that the framework can be indeed used for an accurate determination of resonance pole positions in the multichannel scattering.
|
Nishimura, D., Fujita, Y., Fukuda, M., Ganioglu, E., Ichikawa, Y., Kanazawa, M., et al. (2011). Beta and gamma decays of J(pi)=1(+), Al-24m state beta and gamma branching ratios. Eur. Phys. J. A, 47(12), 155–7pp.
Abstract: A beta-gamma spectroscopy of the J(pi) = 1(+), 426 keV isomeric state of Al-24 ( Al-24m) has been carried out by using a Al-24 secondary beam with high purity and high isomeric ratio. From the absolute gamma-ray and beta-particle intensities observed in the decay of the isomeric state, the branching ratio R-B of the isomeric gamma-decay from Al-24m to the J(pi) = 4(+), ground state of Al-24 have been derived. The obtained R-B value of 69.6(7)% is much smaller than the previously accepted value of 82.5(30)%. The precise half-life for the isomer decay, T-1/2(m) = 130.9(13) ms, has been also determined in this experiment. Accordingly, the M3 gamma-decay strength B(M3) of the Al-24m decay becomes smaller and the total beta-decay branching ratio becomes larger. In particular, the beta-decay branching ratio to the ground state of Mg-24 becomes 24.3(9)%, which is 2.4 times larger than the previous value of 10.1(28)%. By combining the branching ratio and the half-life, the Gamow-Teller (GT) transition strength B(GT) of 0.0194(7) is deduced for the GT transition from Al-24m to the J(pi) = 0(+), ground state of Mg-24. This value is in good agreement with the values derived from charge-exchange reactions.
|
de Azcarraga, J. A., Izquierdo, J. M., & Picon, M. (2011). Contractions of Filippov algebras. J. Math. Phys., 52(1), 013516–24pp.
Abstract: We introduce in this paper the contractions B-c of n-Lie (or Filippov) algebras B and show that they have a semidirect structure as their n = 2 Lie algebra counterparts. As an example, we compute the nontrivial contractions of the simple A(n+1) Filippov algebras. By using the. Inonu-Wigner and the generalized Weimar-Woods contractions of ordinary Lie algebras, we compare (in the B = A(n+1) simple case) the Lie algebras Lie B-c (the Lie algebra of inner endomorphisms of B-c) with certain contractions (Lie B)(IW) and (Lie B)(W-W) of the Lie algebra Lie B associated with B.
|
de Azcarraga, J. A., & Izquierdo, J. M. (2011). On a class of n-Leibniz deformations of the simple Filippov algebras. J. Math. Phys., 52(2), 023521–13pp.
Abstract: We study the problem of infinitesimal deformations of all real, simple, finite-dimensional Filippov (or n-Lie) algebras, considered as a class of n-Leibniz algebras characterized by having an n-bracket skewsymmetric in its n-1 first arguments. We prove that all n > 3 simple finite-dimensional Filippov algebras (FAs) are rigid as n-Leibniz algebras of this class. This rigidity also holds for the Leibniz deformations of the semisimple n = 2 Filippov (i.e., Lie) algebras. The n = 3 simple FAs, however, admit a nontrivial one-parameter infinitesimal 3-Leibniz algebra deformation. We also show that the n >= 3 simple Filippov algebras do not admit nontrivial central extensions as n-Leibniz algebras of the above class.
|
Rodriguez-Alvarez, M. J., Sanchez, F., Soriano, A., Iborra, A., & Mora, C. (2011). Exploiting symmetries for weight matrix design in CT imaging. Math. Comput. Model., 54(7-8), 1655–1664.
Abstract: In this paper we propose several methods of constructing the system matrix (SM) of a Computed Tomography (CT) scanner with two objectives: (1) to construct SMs in the shortest possible time and store them in an ordinary PC without losing quality, (2) to analyze the possible applications of the proposed method to 3D, taking into account SMs' sizes, computing time and reconstructed image quality. In order to build the SM, we propose two new field of view (FOV) pixellation schemes, based on a polar coordinate system (polar grid) by taking advantage of the polar rotation symmetries of CT devices. Comparisons between the SMs proposed are performed using two phantom and a real CT-simulator images. Global error, contrast, noise and homogeneity of the reconstructed images are discussed.
|
Nguyen, C. V., Gillam, J. E., Brown, J. M. C., Martin, D. V., Nikulin, D. A., & Dimmock, M. R. (2011). Towards Optimal Collimator Design for the PEDRO Hybrid Imaging System. IEEE Trans. Nucl. Sci., 58(3), 639–650.
Abstract: The Pixelated Emission Detector for RadiOisotopes (PEDRO) is a hybrid imaging system designed for the measurement of single photon emission from small animal models. The proof-of-principle device consists of a Compton-camera situated behind a mechanical collimator and is intended to provide optimal detection characteristics over a broad spectral range, from 30 to 511 keV. An automated routine has been developed for the optimization of large-area slits in the outer regions of a collimator which has a central region allocated for pinholes. The optimization was tested with a GEANT4 model of the experimental prototype. The data were blurred with the expected position and energy resolution parameters and a Bayesian interaction ordering algorithm was applied. Images were reconstructed using cone back-projection. The results show that the optimization technique allows the large-area slits to both sample fully and extend the primary field of view (FoV) determined by the pinholes. The slits were found to provide truncation of the back-projected cones of response and also an increase in the success rate of the interaction ordering algorithm. These factors resulted in an increase in the contrast and signal-to-noise ratio of the reconstructed image estimates. Of the two configurations tested, the cylindrical geometry outperformed the square geometry, primarily because of a decrease in artifacts. This was due to isotropic modulation of the cone surfaces, that can be achieved with a circular shape. Also, the cylindrical geometry provided increased sampling of the FoV due to more optimal positioning of the slits. The use of the cylindrical collimator and application of the transmission function in the reconstruction was found to improve the resolution of the system by a factor of 20, as compared to the uncollimated Compton camera. Although this system is designed for small animal imaging, the technique can be applied to any application of single photon imaging.
|
Miñano, M. (2011). Radiation Hard Silicon Strips Detectors for the SLHC. IEEE Trans. Nucl. Sci., 58(3), 1135–1140.
Abstract: While the Large Hadron Collider (LHC) began taking data in 2009, scenarios for a machine upgrade to achieve a much higher luminosity are being developed. In the current planning, it is foreseen to increase the luminosity of the LHC at CERN around 2018. As radiation damage scales with integrated luminosity, the particle physics experiments will need to be equipped with a new generation of radiation hard detectors. This article reports on the status of the R&D projects on radiation hard silicon strips detectors for particle physics, linked to the Large Hadron Collider Upgrade, super-LHC (sLHC) of the ATLAS microstrip detector. The primary focus of this report is on measuring the radiation hardness of the silicon materials and the detectors under study. This involves designing silicon detectors, irradiating them to the sLHC radiation levels and studying their performance as particle detectors. The most promising silicon detector for the different radiation levels in the different regions of the ATLAS microstrip detector will be presented. Important challenges related to engineering layout, powering, cooling and reading out a very large strip detector are presented. Ideas on possible schemes for the layout and support mechanics will be shown.
|
Carrio, F., Castillo Gimenez, V., Ferrer, A., Gonzalez, V., Higon-Rodriguez, E., Marin, C., et al. (2011). Optical Link Card Design for the Phase II Upgrade of TileCal Experiment. IEEE Trans. Nucl. Sci., 58(4), 1657–1663.
Abstract: This paper presents the design of an optical link card developed in the frame of the R&D activities for the phase 2 upgrade of the TileCal experiment. This board, that is part of the evaluation of different technologies for the final choice in the next years, is designed as a mezzanine that can work independently or be plugged in the optical multiplexer board of the TileCal backend electronics. It includes two SNAP 12 optical connectors able to transmit and receive up to 75 Gb/s and one SFP optical connector for lower speeds and compatibility with existing hardware as the read out driver. All processing is done in a Stratix II GX field-programmable gate array (FPGA). Details are given on the hardware design, including signal and power integrity analysis, needed when working with these high data rates and on firmware development to obtain the best performance of the FPGA signal transceivers and for the use of the GBT protocol.
|