|
NEXT Collaboration(Haefner, J. et al), Carcel, S., Carrion, J. V., Lopez-March, N., Martin-Albo, J., Muñoz Vidal, J., et al. (2024). Demonstration of event position reconstruction based on diffusion in the NEXT-white detector. Eur. Phys. J. C, 84(5), 518–13pp.
Abstract: Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from Kr-83m calibration electron captures (E similar to 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E >= 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q(beta beta) in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
|
|
|
Anzivino, G. et al, Gonzalez-Alonso, M., Passemar, E., & Pich, A. (2024). Workshop summary: Kaons@CERN 2023. Eur. Phys. J. C, 84(4), 377–34pp.
Abstract: Kaon physics is at a turning point – while the rare-kaon experiments NA62 and KOTO are in full swing, the end of their lifetime is approaching and the future experimental landscape needs to be defined. With HIKE, KOTO-II and LHCb-Phase-II on the table and under scrutiny, it is a very good moment in time to take stock and contemplate about the opportunities these experiments and theoretical developments provide for particle physics in the coming decade and beyond. This paper provides a compact summary of talks and discussions from the Kaons@CERN 2023 workshop, held in September 2023 at CERN.
|
|
|
Lin, J. X., Li, J. T., Liang, W. H., Chen, H. X., & Oset, E. (2024). J/ψ decays into ω(φ) f1(1285) and ω(φ) “f1(1420)”. Eur. Phys. J. C, 84(1), 52–8pp.
Abstract: We perform a theoretical study of the J/psi -> omega (Phi)K* K + c.c. -> omega(Phi)K-0 pi+ K- reactions with the assumption that the f1(1285) is dynamically generated from a single channel K*K + c.c interaction in the chiral unitary approach. Two peaks in the K-0 pi+ K- invariant mass distribution are observed, one clear peak locates at the f(1)(1285) nominal mass, the other peak locates at around 1420MeV with about 70MeV width. We conclude that the former peak is associated with the f(1)(1285) and the latter peak is not a genuine resonance but a manifestation of the kinematic effect in the higher energy region caused by the K* K + c.c. decay mode of the f(1)(1285).
|
|
|
ATLAS Collaboration(Aad, G. et al), Amos, K. R., Aparisi Pozo, J. A., Bailey, A. J., Bouchhar, N., Cabrera Urban, S., et al. (2024). Study of Z → llγ decays at √s=8 TeV with the ATLAS detector. Eur. Phys. J. C, 84(2), 195–29pp.
Abstract: This paper presents a study of Z -> ll gamma decays with the ATLAS detector at the Large Hadron Collider. The analysis uses a proton-proton data sample corresponding to an integrated luminosity of 20.2 fb(-1) collected at a centre-of-mass energy root s = 8 TeV. Integrated fiducial cross-sections together with normalised differential fiducial cross-sections, sensitive to the kinematics of final-state QED radiation, are obtained. The results are found to be in agreement with state-of-the-art predictions for final-state QED radiation. First measurements of Z -> ll gamma gamma decays are also reported.
|
|
|
Plaza, J., Bécares, V., Cano-Ott, D., Gómez, C., Martínez, T., Mendoza, E., et al. (2023). CLYC as a neutron detector in low background conditions. Eur. Phys. J. C, 83(11), 1049–10pp.
Abstract: We report on the thermal neutron flux measurements carried out at the Laboratorio Subterraneo de Canfranc (LSC) with two commercial 2 '' x 2 '' CLYC detectors. The measurements were performed as part of an experimental campaign at LSC with He-3 detectors, for establishing the sensitivity limits and use of CLYCs in low background conditions. Acareful characterization of the intrinsic alpha and gamma-ray background in the detectors was required and done with dedicated measurements. It was found that the alpha activities in the two CLYC crystals differ by a factor of three, and the use of Monte Carlo simulations and a Bayesian unfolding method allowed us to determine the specific alpha activities from the U-238 and Th-232 decay chains. The simulations and unfolding also revealed that the gamma-ray background registered in the detectors is dominated by the intrinsic activity of the components of the detector such as the aluminum housing and photo-multiplier and that the activity within the crystal is low in comparison. The data from the neutron flux measurements with the two detectors were analyzed with different methodologies: one based on an innovative alpha/neutron pulse shape discrimination method and one based on the subtraction of the intrinsic alpha background that masks the neutron signals in the region of interest. The neutron sensitivity of the CLYCs was calculated by Monte Carlo simulations with MCNP6 and GEANT4. The resulting thermal neutron fluxes are in good agreement with complementary flux measurement performed with He-3 detectors, but close to the detection limit imposed by the intrinsic a activity.
|
|