|
NEXT Collaboration(Rogers, L. et al), Alvarez, V., Benlloch-Rodriguez, J. M., Botas, A., Carcel, S., Carrion, J. V., et al. (2018). High voltage insulation and gas absorption of polymers in high pressure argon and xenon gases. J. Instrum., 13, P10002–19pp.
Abstract: High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which still await proper characterization in high pressure noble gas environments. As HPGTPCs increase in size toward ton-scale detectors, assemblies become larger and more complex, creating a need for detailed understanding of how structural supports and high voltage insulators behave. This includes identification of materials with predictable mechanical properties and without surface charge accumulation that may lead to field deformation or sparking. This paper explores the mechanical and electrical effects of high pressure gas environments on insulating polymers PTFE, HDPE, PEEK, POM and UHMW in argon and xenon, including studying gas absorption, swelling and high voltage insulation strength.
|
|
|
NEXT Collaboration(Henriques, C. A. O. et al), Alvarez, V., Benlloch-Rodriguez, J. M., Botas, A., Carcel, S., Carrion, J. V., et al. (2019). Electroluminescence TPCs at the thermal diffusion limit. J. High Energy Phys., 01(1), 027–23pp.
Abstract: The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the Xe-136 isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 for pure xenon down to 2.5 using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.
|
|
|
T2K Collaboration(Abe, K. et al), Antonova, M., Cervera-Villanueva, A., Fernandez, P., Izmaylov, A., & Novella, P. (2018). Search for CP Violation in Neutrino and Antineutrino Oscillations by the T2K Experiment with 2.2 x 10(21) Protons on Target. Phys. Rev. Lett., 121(17), 171802–9pp.
Abstract: The T2K experiment measures muon neutrino disappearance and electron neutrino appearance in accelerator-produced neutrino and antineutrino beams. With an exposure of 14.7(7.6) x 10(20) protons on target in the neutrino (antineutrino) mode, 89 nu(e) candidates and seven anti-nu(e) candidates are observed, while 67.5 and 9.0 are expected for delta(CP) = 0 and normal mass ordering. The obtained 2 sigma confidence interval for the CP-violating phase, delta(CP), does not include the CP-conserving cases (delta(CP) = 0, pi). The best-fit values of other parameters are sin(2) theta(23) = 0.526(-0.036)(+0.032) and Delta m(32)(2) = 2.463(-0.070)(+0.071) x 10(-3) eV(2)/c(4).
|
|
|
NEXT Collaboration(Renner, J. et al), Martinez-Lema, G., Alvarez, V., Benlloch-Rodriguez, J. M., Botas, A., Carcel, S., et al. (2018). Initial results on energy resolution of the NEXT-White detector. J. Instrum., 13, P10020–14pp.
Abstract: One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with Cs-137 and Th-232 sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q(beta beta).
|
|
|
NEMO-3 Collaboration(Argyriades, J. et al), Diaz, J., Martin-Albo, J., Monrabal, F., Novella, P., Serra, L., et al. (2011). Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors. Nucl. Instrum. Methods Phys. Res. A, 625(1), 20–28.
Abstract: We have constructed a GEANT4-based detailed software model of photon transport in plastic sontillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutnnoless double beta decay We compare our simulations to measurements using conversion electrons from a calibration source of (BI)-B-207 and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account In this article we briefly describe our modeling approach and results of our studies.
|
|