BABAR and Belle Collaborations(Adachi, I. et al), Martinez-Vidal, F., & Oyanguren, A. (2018). Measurement of cos 2 beta in B-0 -> D((*))h(0) with D -> K-S(0)pi(+) pi(-) decays by a combined time-dependent Dalitz plot analysis of BABAR and Belle data. Phys. Rev. D, 98(11), 112012–29pp.
Abstract: We report measurements of sin 2 beta and cos 2 beta using a time-dependent Dalitz plot analysis of B-0 -> D((*))h(0) with D -> K-S(0)pi(+)pi(-) decays, where the light unflavored and neutral hadron h(0) is a pi(0),eta, or omega meson. The analysis uses a combination of the final data sets of the BABAR and Belle experiments containing 471 x 10(6) and 772 x 10(6) B (B) over bar pairs collected at the gamma(4S) resonance at the asymmetric-energy B factories PEP-II at SLAC and KEKB at KEK, respectively. We measure sin 2 beta = 0.80 +/- 0.14(stat) +/- 0.06(syst) +/- 0.03(model) and cos 2 beta = 0.91 +/- 0.22(stat) +/- 0.09(syst) +/- 0.07(model). The result for the direct measurement of the angle is beta = (22.5 +/- 4.4(stat) +/- 1.2(syst) +/- 0.6(model))degrees. The last quoted uncertainties are due to the composition of the D-0 -> K-S(0)pi(+)pi(-) decay amplitude model, which is newly established by a Dalitz plot amplitude analysis of a high-statistics e(+) e(-) -> c (c) over bar data sample as part of this analysis. We find the first evidence for cos 2 beta > 0 at the level of 3.7 standard deviations. The measurement excludes the trigonometric multifold solution pi/2 – beta = (68.1 +/- 0.7)degrees at the level of 7.3 standard deviations and therefore resolves an ambiguity in the determination of the apex of the CKM Unitarity Triangle. The hypothesis of beta = 0 degrees is ruled out at the level of 5.1 standard deviations, and thus CP violation is observed in B-0 -> D-(*) h(0) decays. The measurement assumes no direct CP violation in B-0 -> D-(*) h(0) decays.
|
Alvarez, V., Herrero-Bosch, V., Esteve, R., Laing, A., Rodriguez, J., Querol, M., et al. (2019). The electronics of the energy plane of the NEXT-White detector. Nucl. Instrum. Methods Phys. Res. A, 917, 68–76.
Abstract: This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit(-1) in the chain of Bi-214. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4 mV.
|
Barenboim, G., Masud, M., Ternes, C. A., & Tortola, M. (2019). Exploring the intrinsic Lorentz-violating parameters at DUNE. Phys. Lett. B, 788, 308–315.
Abstract: Neutrinos can push our search for new physics to a whole new level. What makes them so hard to be detected, what allows them to travel humongous distances without being stopped or deflected allows to amplify Planck suppressed effects (or effects of comparable size) to a level that we can measure or bound in DUNE. In this work we analyze the sensitivity of DUNE to CPT and Lorentz-violating interactions in a framework that allows a straightforward extrapolation of the bounds obtained to any phenomenological modification of the dispersion relation of neutrinos.
|
ATLAS Collaboration(Aaboud, M. et al), Alvarez Piqueras, D., Bailey, A. J., Barranco Navarro, L., Cabrera Urban, S., Carrio Argos, F., et al. (2018). Operation and performance of the ATLAS Tile Calorimeter in Run 1. Eur. Phys. J. C, 78(12), 987–48pp.
Abstract: The Tile Calorimeter is the hadron calorimeter covering the central region of the ATLAS experiment at the Large Hadron Collider. Approximately 10,000 photomultipliers collect light from scintillating tiles acting as the active material sandwiched between slabs of steel absorber. This paper gives an overview of the calorimeter's performance during the years 2008-2012 using cosmic-ray muon events and proton-proton collision data at centre-of-mass energies of 7 and 8 TeV with a total integrated luminosity of nearly 30 fb(-1). The signal reconstruction methods, calibration systems as well as the detector operation status are presented. The energy and time calibration methods performed excellently, resulting in good stability of the calorimeter response under varying conditions during the LHC Run 1. Finally, the Tile Calorimeter response to isolated muons and hadrons as well as to jets from proton-proton collisions is presented. The results demonstrate excellent performance in accord with specifications mentioned in the Technical Design Report.
|
NEXT Collaboration(Henriques, C. A. O. et al), Alvarez, V., Benlloch-Rodriguez, J. M., Botas, A., Carcel, S., Carrion, J. V., et al. (2019). Electroluminescence TPCs at the thermal diffusion limit. J. High Energy Phys., 01(1), 027–23pp.
Abstract: The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the Xe-136 isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 for pure xenon down to 2.5 using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.
|