toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links (up)
Author Plompen, A.J.M. et al; Algora, A. doi  openurl
  Title The joint evaluated fission and fusion nuclear data library, JEFF-3.3 Type Journal Article
  Year 2020 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 56 Issue 7 Pages 181 - 108pp  
  Keywords  
  Abstract The joint evaluated fission and fusion nuclear data library 3.3 is described. New evaluations for neutron-induced interactions with the major actinides 235U, 238U and 239Pu, on 241Am and 23Na, 59Ni, Cr, Cu, Zr, Cd, Hf, W, Au, Pb and Bi are presented. It includes new fission yields, prompt fission neutron spectra and average number of neutrons per fission. In addition, new data for radioactive decay, thermal neutron scattering, gamma-ray emission, neutron activation, delayed neutrons and displacement damage are presented. JEFF-3.3 was complemented by files from the TENDL project. The libraries for photon, proton, deuteron, triton, helion and alpha-particle induced reactions are from TENDL-2017. The demands for uncertainty quantification in modeling led to many new covariance data for the evaluations. A comparison between results from model calculations using the JEFF-3.3 library and those from benchmark experiments for criticality, delayed neutron yields, shielding and decay heat, reveals that JEFF-3.3 performes very well for a wide range of nuclear technology applications, in particular nuclear energy.  
  Address [Plompen, A. J. M.; Hambsch, F-J; Kopecky, S.; Schillebeeckx, P.; Zerovnik, G.] Joint Res Ctr, European Commiss, B-2440 Geel, Belgium, Email: arjan.plompen@ec.europa.eu  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000553469600001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4483  
Permanent link to this record
 

 
Author AGATA Collaboration (Korten, W. et al); Gadea, A. doi  openurl
  Title Physics opportunities with the Advanced Gamma Tracking Array: AGATA Type Journal Article
  Year 2020 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 56 Issue 5 Pages 137 - 33pp  
  Keywords  
  Abstract New physics opportunities are opening up by the Advanced Gamma Tracking Array, AGATA, as it evolves to the full 4 pi instrument. AGATA is a high-resolution gamma -ray spectrometer, solely built from highly segmented high-purity Ge detectors, capable of measuring gamma rays from a few tens of keV to beyond 10 MeV, with unprecedented efficiency, excellent position resolution for individual gamma -ray interactions, and very high count-rate capability. As a travelling detector AGATA will be employed at all major current and near-future European research facilities delivering stable and radioactive ion beams.  
  Address [Clement, E.] CEA DRF CNRS IN2P3, GANIL, Bd Henri Becquerel,BP 55027, F-14076 Caen 05, France, Email: w.korten@cea.fr  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000537289700004 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4422  
Permanent link to this record
 

 
Author Lewandowski, L.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Clemente, E.; Eberth, J.; Hess, H.; Michelagnoli, C.; Li, H.; Perez-Vidal, R.M.; Zielinska, M. doi  openurl
  Title Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors Type Journal Article
  Year 2019 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 55 Issue 5 Pages 81 - 13pp  
  Keywords  
  Abstract The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a -ray source measurement based on e+e- annihilation radiation after decays of Na-22 by + decay. The first interaction positions of the two 511keV rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.  
  Address [Lewandowski, L.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany, Email: preiter@ikp.uni-koeln.de  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000468893200002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4023  
Permanent link to this record
 

 
Author Testov, D. et al; Gadea, A. doi  openurl
  Title The 4pi highly-efficient light-charged-particle detector EUCLIDES, installed at the GALILEO array for in-beam gamma-ray spectroscopy Type Journal Article
  Year 2019 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 55 Issue 4 Pages 47 - 8pp  
  Keywords  
  Abstract .In a fusion-evaporation reaction, nuclei are produced by evaporating light-charged particles and neutrons from the compound nucleus. Typically, a nucleus of interest is produced as a result of a part of the total cross-section and, in order to guarantee a good channel discrimination, a particle detector, like the EUCLIDES 4 Si-ball array, is necessary. EUCLIDES has been quoted in more than a hundred publications resulting from many experiments performed in combination with the EUROBALL and GASP -ray spectrometers. The present paper reports on the upgraded version of EUCLIDES, that is presently coupled to the new GALILEO -ray spectrometer, installed at the Laboratori Nazionali di Legnaro, INFN. The design, characteristics and performance of the EUCLIDES array are presented and discussed.  
  Address [Testov, D.; Mengoni, D.; Goasduff, A.; John, P. R.; Boso, A.; Canet, F. J. Egea; Grassi, L.; Lunardi, S.; Recchia, F.] Univ Padua, Dipartimento Fis & Astron, Padua, Italy, Email: testov@lnl.infn.it  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000462944600001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3965  
Permanent link to this record
 

 
Author Rinaldi, M.; Vento, V. doi  openurl
  Title Scalar and tensor glueballs as gravitons Type Journal Article
  Year 2018 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 54 Issue 9 Pages 151 - 7pp  
  Keywords  
  Abstract The bottom-up approach of the AdS/CFT correspondence leads to the study of field equations in an AdS(5) background and from their solutions to the determination of the hadronic mass spectrum. We extend the study to the equations of AdS(5) gravitons and determine from them the glueball spectrum. We propose an original presentation of the results which facilitates the comparison of the various models with the spectrum obtained by lattice QCD. This comparison allows to draw some phenomenological conclusions.  
  Address [Rinaldi, Matteo; Vento, Vicente] Univ Valencia, CSIC, Dept Fis Teor, IFIC, E-46100 Burjassot, Valencia, Spain, Email: vicente.vento@uv.es  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000444638600003 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 3732  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva