toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links (up)
Author Oset, E.; Chen, H.X.; Feijoo, A.; Geng, L.S.; Liang, W.H.; Li, D.M.; Lu, J.X.; Magas, V.K.; Nieves, J.; Ramos, A.; Roca, L.; Wang, E.; Xie, J.J. doi  openurl
  Title Study of reactions disclosing hidden charm pentaquarks with or without strangeness Type Journal Article
  Year 2016 Publication Nuclear Physics A Abbreviated Journal Nucl. Phys. A  
  Volume 954 Issue Pages 371-392  
  Keywords Pentaquark reactions; Molecular states with hidden charm  
  Abstract We present results for five reactions, Lambda(b) -> J/psi K(-)p, Lambda(b) -> J/psi eta Lambda, Lambda(b) -> J/psi pi(-)p, Lambda(b) -> J/psi K-0 Lambda and Xi(-)(b) -> J/psi K-Lambda, where combining information from the meson baryon interaction, using the chiral unitary approach, and predictions made for molecular states of hidden charm, with or without strangeness, we can evaluate invariant mass distributions for the light meson baryon states, and for those of J/psi p or J/psi Lambda. We show that with the present available information, in all of these reactions one finds peaks where the pentaquark states show up. In the Lambda(b) -> J/psi K(-)p, and Lambda(b) -> J/psi pi(-)p reactions we show that the results obtained from our study are compatible with present experimental observations.  
  Address [Oset, Eulogio] Univ Valencia, Ctr Mixto, CSIC, Inst Invest Paterna,Dept Fis Teor, Aptdo 22085, E-46071 Valencia, Spain, Email: oset@ific.uv.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0375-9474 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000381331200025 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2791  
Permanent link to this record
 

 
Author Lauritsen, T. et al; Perez-Vidal, R.M. doi  openurl
  Title Characterization of a gamma-ray tracking array: A comparison of GRETINA and Gammasphere using a Co-60 source Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 836 Issue Pages 46-56  
  Keywords Segmented germanium detectors; Efficiency measurements; gamma-Ray tracking; Gammasphere; GRETINA; GRETA; gamma-Ray spectroscopy; Nuclear structure  
  Abstract In this paper; we provide a formalism for the characterization of tracking arrays with emphasis on the proper corrections required to extract their photopeak efficiencies and peak-to-total ratios. The methods are first applied to Gammasphere, a well characterized 4 pi array based on the principle of Compton suppression, and subsequently to GRETINA. The tracking efficiencies are then discussed and some guidelines as to what clustering angle to use in the tracking algorithm are presented. It was possible, using GEANT4 simulations, to scale the measured efficiencies up to the expected values for the full 4 pi implementation of GRETA.  
  Address [Lauritsen, T.; Zhu, S.; Ayangeakaa, A. D.; Carpenter, M. P.; Greene, J. P.; Janssens, R. V. F.; Khoo, T. L.; Seweryniak, D.] Argonne Natl Lab, 9700 S Cass Ave, Argonne, IL 60439 USA, Email: torben@anl.gov  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000385601400007 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2830  
Permanent link to this record
 

 
Author Benitez, V. et al; Bernabeu, J.; Garcia, C.; Lacasta, C.; Marco, R.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U. doi  openurl
  Title Sensors for the End-cap prototype of the Inner Tracker in the ATLAS Detector Upgrade Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 833 Issue Pages 226-232  
  Keywords Silicon radiation detectors; Strip sensors; HL-LHC; ATLAS Upgrade; Inner Tracker (ITk); End-cap  
  Abstract The new silicon microstrip sensors of the End-cap part of the HL-LHC ATLAS Inner Tracker (ITk) present a number of challenges due to their complex design features such as the multiple different sensor shapes, the varying strip pitch, or the built-In stereo angle. In order to investigate these specific problems, the “petalet” prototype was defined as a small End-cap prototype. The sensors for the petalet prototype include several new layout and technological solutions to investigate the issues, they have been tested in detail by the collaboration. The sensor description and detailed test results are presented in this paper. New software tools have been developed for the automatic layout generation of the complex designs. The sensors have been fabricated, characterized and delivered to the institutes in the collaboration for their assembly on petalet prototypes. This paper describes the lessons learnt from the design and tests of the new solutions implemented on these sensors, which are being used for the full petal sensor development. This has resulted in the ITIc strip, community acquiring the necessary expertise to develop the full End-cap structure, the petal.  
  Address [Benitez, V.; Ullan, M.; Quirion, D.; Pellegrini, G.; Fleta, C.; Lozano, M.] CSIC, CNM, IMB, Campus Univ Bellaterra, Barcelona 08193, Spain, Email: miguel.ullan@imb-cnm.csic.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000383818200032 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2816  
Permanent link to this record
 

 
Author Jordan, D.; Algora, A.; Tain, J.L. doi  openurl
  Title An event generator for simulations of complex beta-decay experiments Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 828 Issue Pages 52-57  
  Keywords Monte Carlo event generator; Complex beta-decay experiments simulations  
  Abstract This article describes a Monte Carlo event generator for the design, optimization and performance characterization of beta decay spectroscopy experimental set-ups. The event generator has been developed within the Geant4 simulation architecture and provides new features and greater flexibility in comparison with the current available decay generator.  
  Address [Jordan, D.; Algora, A.; Tain, J. L.] Univ Valencia, CSIC, Ctr Mixto, Inst Fis Corpuscular, Valencia, Spain, Email: jordan@ific.uv.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000377399700007 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2714  
Permanent link to this record
 

 
Author Hernandez-Prieto, A.; Quintana, B.; Martin, S.; Domingo-Pardo, C. doi  openurl
  Title Study of accuracy in the position determination with SALSA, a gamma-scanning system for the characterization of segmented HPGe detectors Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 823 Issue Pages 98-106  
  Keywords gamma-Camera; Virtual collimation; SAlamanca Lyso-based Scanning Array (SALSA); Segmented HPGe detectors  
  Abstract Accurate characterization of the electric response of segmented high-purity germanium (HPGe) detectors as a function of the interaction position is one of the current goals of the Nuclear Physics community seeking to perform gamma-ray tracking or even imaging with these detectors. For this purpose, scanning devices must be developed to achieve the signal-position association with the highest precision. With a view to studying the accuracy achieved with SALSA, the SAlamanca Lyso-based Scanning Array, here we report a detailed study on the uncertainty sources and their effect in the position determination inside the HPGe detector to be scanned. The optimization performed on the design of SALSA, aimed at minimizing the effect of the uncertainty sources, afforded an intrinsic uncertainty of 2 mm for large coaxial detectors and 1 mm for planar ones.  
  Address [Hernandez-Prieto, A.; Quintana, B.; Martin, S.] Univ Salamanca, Dept Fis Fundamental, Lab Radiac Ionizantes, C Espejo S-N, E-37008 Salamanca, Spain, Email: alvaro.prieto@usal.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000374661600014 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 2664  
Permanent link to this record
 

 
Author Faus-Golfe, A.; Navarro, J.; Fuster Martinez, N.; Resta Lopez, J.; Giner Navarro, J. doi  openurl
  Title Emittance reconstruction from measured beam sizes in ATF2 and perspectives for ILC Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 819 Issue Pages 122-138  
  Keywords Beam size; Emittance; Linear Colliders  
  Abstract The projected emittance (2D) and the intrinsic emittance (4D) reconstruction method by using the beam size measurements at different locations is analyzed in order to study analytically the conditions of solvability of the systems of equations involved in this process. Some conditions are deduced and discussed, and general guidelines about the locations of the measurement stations have been obtained to avoid unphysical results. The special case of the multi-Optical Transition Radiation system (m-OTR), made of four measurement stations, in the Extraction Line (EXT) of Accelerator Test Facility 2 (ATF2) has been simulated in much detail and compared with measurements. Finally a feasibility study of a multi station system for fast transverse beam size measurement, emittance reconstruction and coupling correction in the Ring to Main Linac (RTML) of International Linear Collider (ILC) Diagnostic sections of the RTML has been discussed in detail.  
  Address [Faus-Golfe, A.; Navarro, J.; Fuster Martinez, N.; Giner Navarro, J.] Inst Fis Corpuscular CSIC UV, Madrid, Spain  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000372318800017 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2581  
Permanent link to this record
 

 
Author Agramunt, J. et al; Tain, J.L.; Albiol, F.; Algora, A.; Domingo-Pardo, C.; Jordan, M. D.; Rubio, B.; Tarifeño-Saldivia, A.; Valencia, E. doi  openurl
  Title Characterization of a neutron-beta counting system with beta-delayed neutron emitters Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 807 Issue Pages 69-78  
  Keywords Beta-delayed neutron emission probability; Neutron and beta counters; Self-triggered digital data acquisition system; Geant4 simulations  
  Abstract A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known beta-delayed neutron emission properties. The setup consists of BELEN-20, a 4 pi-neutron counter with twenty He-3 proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for beta counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, beta and beta-neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on the accuracy of neutron emission probabilities is discussed. A new accurate value of the neutron emission probability for the important delayed-neutron precursor I-137 was obtained, P-n = 7.76(14)%.  
  Address [Agramunt, J.; Tain, J. L.; Albiol, E.; Algora, A.; Domingo-Pardo, C.; Jordan, M. D.; Rubio, B.; Tarifeno-Saldivia, A.; Valencia, E.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46071 Valencia, Spain, Email: Tain@ific.uv.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000365596200010 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2481  
Permanent link to this record
 

 
Author Lalovic, N.; Louchart, C.; Michelagnoli, C.; Perez-Vidal, R.M.; Ralet, D.; Gerl, J.; Rudolph, D.; Arici, T.; Bazzacco, D.; Clement, E.; Gadea, A.; Kojouharov, I.; Korichi, A.; Labiche, M.; Ljungvall, J.; Lopez-Martens, A.; Nyberg, J.; Pietralla, N.; Pietri, S.; Stezowski, O. doi  openurl
  Title Performance of the AGATA gamma-ray spectrometer in the PreSPEC set-up at GSI Type Journal Article
  Year 2016 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A  
  Volume 806 Issue Pages 258-266  
  Keywords Gamma-ray spectroscopy; Gamma-ray tracking; Nuclear structure; Pulse shape analysis; HPGe detectors  
  Abstract In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the y-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the 7 ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC-AGATA experimental campaign at the GSI Helmholtzzentrum fur Schwerionenforschung. Using the radioactive sources Co-56, Co-60 and Eu-152, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated.  
  Address [Lalovic, N.; Rudolph, D.] Lund Univ, Dept Phys, SE-22100 Lund, Sweden, Email: Natasa.Lalovic@nuclear.lu.se  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000364856100035 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2463  
Permanent link to this record
 

 
Author Lloret, E.; Fernandez, A.; Trbojevich, R.; Arnau, J.; Picouet, P.A. doi  openurl
  Title Relevance of nanocomposite packaging on the stability of vacuum-packed dry cured ham Type Journal Article
  Year 2016 Publication Meat Science Abbreviated Journal Meat Sci.  
  Volume 118 Issue Pages 8-14  
  Keywords Clay; Nanocomposite; Polyamide; Skin; TBARS; Vacuum; Meat; Ham  
  Abstract In this study effects of a novel high barrier multilayer polyamide film containing dispersed nanoclays (PAN) on the stability of vacuum packed dry-cured ham were investigated during 90 days refrigerated storage in comparison with non-modified multilayer polyamide (PA) and a commercial high barrier film. Characteristic bands of the mineral in FT-IR spectra confirmed the presence of nanoclays in PAN, enhancing oxygen transmission barrier properties and UV protection. Packaging in PAN films did not originate significant changes on colour or lipid oxidation during prolonged storage of vacuum-packed dry-cured ham. Larger oxygen transmission rates in PA films caused changes in CIE b* during refrigerated storage. Ham quality was not affected by light exposition during 90 days and only curing had a significant benefit on colour and TBARS, being cured samples more stable during storage in all the packages used. Packaging of dry-cured ham in PAN was equivalent to commercial high barrier films.  
  Address [Lloret, Elsa; Arnau, Jacint; Picouet, Pierre A.] IRTA, Dept Tecnol Aliments, Monells, Girona, Spain, Email: pierre.picouet@irta.cat  
  Corporate Author Thesis  
  Publisher Elsevier Sci Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0309-1740 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000380581100002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2774  
Permanent link to this record
 

 
Author Lloret, E.; Picouet, P.A.; Trbojevich, R.; Fernandez, A. doi  openurl
  Title Colour stability of cooked ham packed under modified atmospheres in polyamide nanocomposite blends Type Journal Article
  Year 2016 Publication Lwt-Food Science And Technology Abbreviated Journal LWT-Food Sci. Technol.  
  Volume 66 Issue Pages 582-589  
  Keywords Nylon; Cooked ham; Nanoclays; Oxygen permeation; Colour; Exfoliation; MAP  
  Abstract Two novel blends containing a low-density polyethylene (LDPE) and a neat polyamide (PA) or a polyamide nanocomposite (PAN) layers were fabricated and their technological potential was evaluated during the refrigeration of cooked ham in modified atmospheres (MAP). Nanoclays were homogeneously distributed and nearly exfoliated, and they lowered significantly the oxygen transmission rate (OTR) of the PAN films. Due to the lower OTR, the headspace oxygen level in PAN pouches do not rise above 0.26% but it approached 2% in PA pouches at day 20. The residual oxygen levels were key for colour change during MAP storage of cooked ham. Cooked ham redness and reflectivity were stable during 27 days in PAN pouches while a strong colour deterioration took place after day 7 in PA pouches. Other parameters such as moisture content and water activity remained unaltered, and pH development was related to microbial growth and independent of the packaging polymer. The evolution of cooked ham colour in PAN was comparable to a high-barrier commercial polymer, and was acceptable for commercial sale for 27 days, showing excellent perspectives for polyamide nanocomposites in the storage of cooked ham.  
  Address [Lloret, Elsa; Picouet, Pierre A.] IRTA, Dept Tecnol Dels Aliments, Monells, Girona, Spain, Email: velifdez@ific.uv.es  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0023-6438 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000367413200079 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 2510  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva