toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links (up)
Author Koolen, B.B.; Vidal-Sicart, S.; Benlloch, J.M.; Olmos, R.A.V. doi  openurl
  Title Evaluating heterogeneity of primary tumor 18 F-FDG uptake in breast cancer with a dedicated breast PET ( MAMMI): a feasibility study based on correlation with PET/CT Type Journal Article
  Year 2014 Publication Nuclear Medicine Communications Abbreviated Journal Nucl. Med. Commun.  
  Volume 35 Issue 5 Pages 446-452  
  Keywords breast cancer; F-18-FDG; heterogeneity; MAMMI; PET  
  Abstract PurposeThe aim of the study was to evaluate the heterogeneity of primary tumor F-18-fluorodeoxyglucose (F-18-FDG) uptake in breast cancer patients using a dedicated breast PET.Patients and methodsA positron emission tomography/computed tomography (PET/CT) of the thorax was performed 60 min after administration of 180-240 MBq of F-18-FDG in patients with breast cancer. Subsequently, 110 min after injection, a scan was taken with a dedicated high-resolution breast PET [MAMmography with Molecular Imaging (MAMMI)]. Both procedures were performed with the patients in the prone position. Four-point scores were used to compare the intensity (0: none; 1: mild; 2: moderate; 3: high) and heterogeneity (0: none; 1: mild; 2: moderate; 3: high) of F-18-FDG uptake between PET/CT and MAMMI images.ResultsThirty-five patients in whom the primary tumor was visualized on both scans were included in this analysis. The mean primary tumor size was 35.1 mm (range 10-108 mm). The mean intensity score was similar on both devices (2.4 for PET/CT and 2.3 for MAMMI; P=0.439), but the mean heterogeneity score on MAMMI images was significantly higher (PET/CT 1.9 vs. MAMMI 2.3; P=0.005). MAMMI showed a higher heterogeneity score in 11 (31%) of 35 patients, especially in tumors with moderate or high intensity. Significantly higher heterogeneity scores on both PET/CT and MAMMI were seen in large tumors (P=0.005 and 0.014, respectively) and in tumors with high intensity scores (P=0.012 and P<0.001, respectively).ConclusionHeterogeneous tumor F-18-FDG uptake in breast cancer is frequently observed, particularly in large tumors with intense F-18-FDG uptake. It is more often seen on MAMMI PET than on conventional PET/CT. Although the observed heterogeneity should be proven histopathologically, this finding offers a rationale for F-18-FDG-guided biopsies.  
  Address [Koolen, Bas B.; Vidal-Sicart, Sergi; Olmos, Renato A. Valdes] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Nucl Med, NL-1066 CX Amsterdam, Netherlands, Email: b.koolen@nki.nl  
  Corporate Author Thesis  
  Publisher Lippincott Williams & Wilkins Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0143-3636 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000334103800002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 1763  
Permanent link to this record
 

 
Author Ros, A.; Lerche, C.W.; Sebastia, A.; Sanchez, F.; Benlloch, J.M. doi  openurl
  Title Retroreflector arrays for better light collection efficiency of gamma-ray imaging detectors with continuous scintillation crystals without DOI misestimation Type Journal Article
  Year 2014 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.  
  Volume 9 Issue Pages P04009 - 14pp  
  Keywords Gamma detectors (scintillators, CZT, HPG, HgI etc); Interaction of radiation with matter; Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA); Detector design and construction technologies and materials  
  Abstract A method to improve light collection efficiency of gamma-ray imaging detectors by using retroreflector arrays has been tested, simulations of the behaviour of the scintillation light illuminating the retroreflector surface have been made. Measurements including retroreflector arrays in the setup have also been taken. For the measurements, positron emission tomography (PET) detectors with continuous scintillation crystals have been used. Each detector module consists of a continuous LSO-scintillator of dimensions 49x49x10 mm(3) and a H8500 position-sensitive photo-multiplier (PSPMT) from Hamamatsu. By using a continuous scintillation crystal, the scintillation light distribution has not been destroyed and the energy, the centroids along the x- and y-direction and the depth of interaction (DOI) can be estimated. Simulations have also been run taking into account the use of continuous scintillation crystals. Due to the geometry of the continuous scintillation crystals in comparison with pixelated crystals, a good light collection efficiency is necessary to correctly reconstruct the impact point of the gamma-ray. The aim of this study is to investigate whether micro-machine retro-reflectors improve light yield without misestimation of the impact point. The results shows an improvement on the energy and centroid resolutions without worsening the depth of interaction resolution. Therefore it can be concluded that using retroreflector arrays at the entrance side of the scintillation crystal improves light collection efficiency without worsening the impact point estimation.  
  Address [Ros, A.] Inst Fis Corpuscular IFIC, Valencia 46980, Spain, Email: anrogar2@i3m.upv.es  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1748-0221 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000336123800049 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 1798  
Permanent link to this record
 

 
Author Diez, S. et al; Bernabeu Verdu, J.; Civera, J.V.; Garcia, C.; Garcia-Argos, C.; Lacasta, C.; Marco, R.; Marti-Garcia, S.; Santoyo, D.; Soldevila, U. doi  openurl
  Title A double-sided, shield-less stave prototype for the ATLAS Upgrade strip tracker for the High Luminosity LHC Type Journal Article
  Year 2014 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.  
  Volume 9 Issue Pages P03012 - 16pp  
  Keywords Large detector-systems performance; Si microstrip and pad detectors; Particle tracking detectors; Performance of High Energy Physics Detectors  
  Abstract A detailed description of the integration structures for the barrel region of the silicon strips tracker of the ATLAS Phase-II upgrade for the upgrade of the Large Hadron Collider, the so-called High Luminosity LHC (HL-LHC), is presented. This paper focuses on one of the latest demonstrator prototypes recently assembled, with numerous unique features. It consists of a shortened, shield-less, and double sided stave, with two candidate power distributions implemented. Thermal and electrical performances of the prototype are presented, as well as a description of the assembly procedures and tools.  
  Address [Diez, S.; Haber, C. H.; Witharm, R.] LBNL, Berkeley, CA 94103 USA, Email: sdiezcornell@lbl.gov  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1748-0221 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000336123200072 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 1802  
Permanent link to this record
 

 
Author Carrio, F.; Kim, H.Y.; Moreno, P.; Reed, R.; Sandrock, C.; Schettino, V.; Shalyugin, A.; Solans, C.; Souza, J.; Usai, G.; Valero, A. doi  openurl
  Title Design of an FPGA-based embedded system for the ATLAS Tile Calorimeter front-end electronics test-bench Type Journal Article
  Year 2014 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.  
  Volume 9 Issue Pages C03023 - 12pp  
  Keywords Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms; databases); Data acquisition concepts; Digital electronic circuits  
  Abstract The portable test-bench for the certification of the ATLAS tile hadronic calorimeter front-end electronics has been redesigned for the present Long Shutdown (LS1) of LHC, improving its portability and expanding its functionalities. This paper presents a new test-bench based on a Xilinx Virtex-5 FPGA that implements an embedded system using a PowerPC 440 microprocessor hard core and custom IP cores. A light Linux version runs on the PowerPC microprocessor and handles the IP cores which implement the different functionalities needed to perform the desired tests such as TTCvi emulation, G-Link decoding, ADC control and data reception.  
  Address [Carrio, F.; Valero, A.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna, Spain, Email: fernando.carrio@cern.ch  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1748-0221 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000336123200023 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 1801  
Permanent link to this record
 

 
Author Esperante-Pereira, D. doi  openurl
  Title DEPFET active pixel sensors for the vertex detector of the Belle-II experiment Type Journal Article
  Year 2014 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.  
  Volume 9 Issue Pages C03004 - 11pp  
  Keywords Particle tracking detectors; Solid state detectors; Particle tracking detectors (Solid-state detectors)  
  Abstract Active pixels sensors based on the DEPFET technology will be used for the innermost vertex detector of the future Belle-II experiment. The increased luminosity of the e(+) e(-) SuperKEKB collider entails challenging detector requirements, namely: low material budget, low power consumption, high precision and efficiency, and a large readout rate. The DEPFET active pixel technology has shown to be a suitable solution for this purpose. A review of the different aspects of the detector design (sensors, readout ASICS and supplementary infrastructure) and the results of the latest thinned sensor prototypes (50 μm) are described.  
  Address Univ Valencia, CSIC, IFIC Inst Fis Corpuscular, Valencia 46980, Spain, Email: daniel.esperante@csic.es  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1748-0221 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000336123200004 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 1803  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva