|
n_TOF Collaboration(Belloni, F. et al), Domingo-Pardo, C., & Tain, J. L. (2011). Neutron-induced fission cross-section of U-233 in the energy range 0.5 < E-n < 20 MeV. Eur. Phys. J. A, 47(1), 2–7pp.
Abstract: The neutron-induced fission cross-section of U-233 has been measured at the CERN nTOF facility relative to the standard fission cross-section of U-235 between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against alpha-particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the nTOF facility result in data with uncertainties of approximate to 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the U-233(n, f) cross-section and, consequently, the design of energy systems based on the Th/U cycle.
|
|
|
Pastor, S. (2011). Light Neutrinos in Cosmology. Phys. Part. Nuclei, 42(4), 628–640.
Abstract: Neutrinos can play an important role in the evolution of the Universe, modifying some of the cosmological observables. We describe how the precision of present cosmological data can be used to learn about neutrino properties, in particular their mass. We show how the analysis of current cosmological observations provides an upper bound on the sum of neutrino masses, with improved sensitivity from future cosmological measurements.
|
|
|
Mondragon, A., Mondragon, M., & Peinado, E. (2011). Neutrino Masses, Mixings, and FCNC's in an S(3) Flavor Symmetric Extension of the Standard Model. Phys. Atom. Nuclei, 74(7), 1046–1054.
Abstract: By introducing three Higgs fields that are SU(2) doublets and a flavor permutational symmetry, S(3), in the theory, we extend the concepts of flavor and generations to the Higgs sector and formulate a Minimal S(3)-Invariant Extension of the Standard Model. The mass matrices of the neutrinos and charged leptons are re-parameterized in terms of their eigenvalues, then the neutrino mixing matrix, V(PMNS), is computed and exact, explicit analytical expressions for the neutrino mixing angles as functions of the masses of neutrinos and charged leptons are obtained in excellent agreement with the latest experimental data. We also compute the branching ratios of some selected flavor-changing neutral current (FCNC) processes, as well as the contribution of the exchange of neutral flavor-changing scalars to the anomaly of the magnetic moment of the muon, as functions of the masses of charged leptons and the neutral Higgs bosons. We find that the S(3) x Z(2) flavor symmetry and the strong mass hierarchy of the charged leptons strongly suppress the FCNC processes in the leptonic sector, well below the present experimental bounds by many orders of magnitude. The contribution of FCNC's to the anomaly of the muon's magnetic moment is small, but not negligible.
|
|
|
Cases, R., Ros, E., & Zuñiga, J. (2011). Measuring radon concentration in air using a diffusion cloud chamber. Am. J. Phys., 79(9), 903–908.
Abstract: Radon concentration in air is a major concern in lung cancer studies. A traditional technique used to measure radon abundance is the charcoal canister method. We propose a novel technique using a diffusion cloud chamber. This technique is simpler and can easily be used for physics demonstrations for high school and university students.
|
|
|
Granero, D., Vijande, J., Ballester, F., & Rivard, M. J. (2011). Dosimetry revisited for the HDR Ir-192 brachytherapy source model mHDR-v2. Med. Phys., 38(1), 487–494.
Abstract: Purpose: Recently, the manufacturer of the HDR Ir-192 mHDR-v2 brachytherapy source reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from 192Ir electrons and considering the absence of electronic equilibrium; and (3) obtain scatter dose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo (MC) radiation transport codes were used: MCNP5, PENELOPE2008, and GEANT4. The source was centrally positioned in a 40 cm radius water phantom. Absorbed dose and collision kerma were obtained using 0.1 mm (0.5 mm) thick voxels to provide high-resolution dosimetry near (far from) the source. Dose-rate distributions obtained with the three MC codes were compared. Results: Simulations of mHDR-v2 and mHDR-v2r designs performed with three radiation transport codes showed agreement typically within 0.2% for r >= 0.25 cm. Dosimetric contributions from source electrons were significant for r<0.25 cm. The dose-rate constant and radial dose function were similar to those from previous MC studies of the mHDR-v2 design. The 2D anisotropy function also coincided with that of the mHDR-v2 design for r >= 0.25 cm. Detailed results of dose distributions and scatter components are presented for the modified source design. Conclusions: Comparison of these results to prior MC studies showed agreement typically within 0.5% for r >= 0.25 cm. If dosimetric data for r<0.25 cm are not needed, dosimetric results from the prior MC studies will be adequate. c 2011 American Association of Physicists in Medicine.
|
|
|
Carrio, F., Castillo Gimenez, V., Ferrer, A., Gonzalez, V., Higon-Rodriguez, E., Marin, C., et al. (2011). Optical Link Card Design for the Phase II Upgrade of TileCal Experiment. IEEE Trans. Nucl. Sci., 58(4), 1657–1663.
Abstract: This paper presents the design of an optical link card developed in the frame of the R&D activities for the phase 2 upgrade of the TileCal experiment. This board, that is part of the evaluation of different technologies for the final choice in the next years, is designed as a mezzanine that can work independently or be plugged in the optical multiplexer board of the TileCal backend electronics. It includes two SNAP 12 optical connectors able to transmit and receive up to 75 Gb/s and one SFP optical connector for lower speeds and compatibility with existing hardware as the read out driver. All processing is done in a Stratix II GX field-programmable gate array (FPGA). Details are given on the hardware design, including signal and power integrity analysis, needed when working with these high data rates and on firmware development to obtain the best performance of the FPGA signal transceivers and for the use of the GBT protocol.
|
|
|
Miñano, M. (2011). Radiation Hard Silicon Strips Detectors for the SLHC. IEEE Trans. Nucl. Sci., 58(3), 1135–1140.
Abstract: While the Large Hadron Collider (LHC) began taking data in 2009, scenarios for a machine upgrade to achieve a much higher luminosity are being developed. In the current planning, it is foreseen to increase the luminosity of the LHC at CERN around 2018. As radiation damage scales with integrated luminosity, the particle physics experiments will need to be equipped with a new generation of radiation hard detectors. This article reports on the status of the R&D projects on radiation hard silicon strips detectors for particle physics, linked to the Large Hadron Collider Upgrade, super-LHC (sLHC) of the ATLAS microstrip detector. The primary focus of this report is on measuring the radiation hardness of the silicon materials and the detectors under study. This involves designing silicon detectors, irradiating them to the sLHC radiation levels and studying their performance as particle detectors. The most promising silicon detector for the different radiation levels in the different regions of the ATLAS microstrip detector will be presented. Important challenges related to engineering layout, powering, cooling and reading out a very large strip detector are presented. Ideas on possible schemes for the layout and support mechanics will be shown.
|
|
|
Nguyen, C. V., Gillam, J. E., Brown, J. M. C., Martin, D. V., Nikulin, D. A., & Dimmock, M. R. (2011). Towards Optimal Collimator Design for the PEDRO Hybrid Imaging System. IEEE Trans. Nucl. Sci., 58(3), 639–650.
Abstract: The Pixelated Emission Detector for RadiOisotopes (PEDRO) is a hybrid imaging system designed for the measurement of single photon emission from small animal models. The proof-of-principle device consists of a Compton-camera situated behind a mechanical collimator and is intended to provide optimal detection characteristics over a broad spectral range, from 30 to 511 keV. An automated routine has been developed for the optimization of large-area slits in the outer regions of a collimator which has a central region allocated for pinholes. The optimization was tested with a GEANT4 model of the experimental prototype. The data were blurred with the expected position and energy resolution parameters and a Bayesian interaction ordering algorithm was applied. Images were reconstructed using cone back-projection. The results show that the optimization technique allows the large-area slits to both sample fully and extend the primary field of view (FoV) determined by the pinholes. The slits were found to provide truncation of the back-projected cones of response and also an increase in the success rate of the interaction ordering algorithm. These factors resulted in an increase in the contrast and signal-to-noise ratio of the reconstructed image estimates. Of the two configurations tested, the cylindrical geometry outperformed the square geometry, primarily because of a decrease in artifacts. This was due to isotropic modulation of the cone surfaces, that can be achieved with a circular shape. Also, the cylindrical geometry provided increased sampling of the FoV due to more optimal positioning of the slits. The use of the cylindrical collimator and application of the transmission function in the reconstruction was found to improve the resolution of the system by a factor of 20, as compared to the uncollimated Compton camera. Although this system is designed for small animal imaging, the technique can be applied to any application of single photon imaging.
|
|
|
Forero, D. V., & Guzzo, M. M. (2011). Constraining nonstandard neutrino interactions with electrons. Phys. Rev. D, 84(1), 013002–7pp.
Abstract: We update the phenomenological constraints of the nonstandard neutrino interactions (NSNI) with electrons including in the analysis, for the first time, data from LAMPF, Krasnoyarsk, and the latest Texono observations. We assume that NSNI modify the cross section of elastic scattering of (anti) neutrinos off electrons, using reactor and accelerator data, and the cross section of the electron-positron annihilation, using the four LEP experiments, in particular, new data from DELPHI. We find more restrictive allowed regions for the NSNI parameters: -0.11< epsilon(eR)(ee) < 0.05 and -0.02 < epsilon(eL)(ee) < 0.09 (90% C.L.). We also recalculate the parameters of tauonic flavor obtaining -0.35 < epsilon(eR)(tau tau) < 0.50 and -0.51 < epsilon(eL)(tau tau) < 0.34 (90% C.L.). Although more severe than the limits already present in the literature, our results indicate that NSNI are allowed by the present data as a subleading effect, and the standard electroweak model continues consistent with the experimental panorama at 90% C.L. Further improvement on this picture will deserve a lot of engagement of upcoming experiments.
|
|
|
Krolas, W. et al, & Gadea, A. (2011). Coupling of the proton-hole and neutron-particle states in the neutron-rich (48)K isotope. Phys. Rev. C, 84(6), 064301–8pp.
Abstract: Excited states in the Z = 19, N = 29 neutron-rich (48)K isotope have been studied using deep-inelastic transfer reactions with a thick target at Gammasphere and with a thin target at the PRISMA-CLARA spectrometer. The lowest excited states were located; they involve a proton hole in the s(1/2) or d(3/2) orbital coupled to a p(3/2) neutron. A new 7.1(5)-ns, 5(+) isomer, the analog of the 7/2 isomer in (47)K, was identified. Based on the observed gamma-decay pattern of the isomer a revised spin-parity assignment of 1(-) is proposed for the ground state of (48)K.
|
|