Weber, M. et al, & Esperante, D. (2024). DONES EVO: Risk mitigation for the IFMIF-DONES facility. Nucl. Mater. Energy, 38, 101622–5pp.
Abstract: The International Fusion Materials Irradiation Facility- DEMO Oriented Neutron Source (IFMIF-DONES) is a scientific infrastructure aimed to provide an intense neutron source for the qualification of materials to be used in future fusion power reactors. Its implementation is critical for the construction of the fusion DEMOnstration Power Plant (DEMO). IFMIF-DONES is a unique facility requiring a broad set of technologies. Although most of the necessary technologies have already been validated, there are still some aspects that introduce risks in the evolution of the project. In order to mitigate these risks, a consortium of companies, with the support of research centres and the funding of the CDTI (Centre for the Development of Industrial Technology and Innovation), has launched the DONES EVO Programme, which comprises six lines of research: center dot Improvement of signal transmission and integrity (planning and integration risks) center dot Optimisation of RF conditioning processes (planning and reliability risks) center dot Development of a reliable beam extraction device (reliability risks) center dot Development of technologies for the production of medical isotopes (reliability risks) center dot Improvement of critical parts of the lithium purification system (safety and reliability risks) center dot Validation of the manufacture of critical components with special materials (reliability risk). DONES EVO will focus on developing the appropriate response to the risks identified in the IFMIFDONES project through research and prototyping around the associated technologies.
|
|
|
Scandale, W. et al, & Lari, L. (2014). Deflection of high energy protons by multiple volume reflections in a modified multi-strip silicon deflector. Nucl. Instrum. Methods Phys. Res. B, 338, 108–111.
Abstract: The effect of multiple volume reflections in one crystal was observed in each of several bent silicon strips for 400 GeV/c protons. This considerably increased the particle deflections. Some particles were also deflected due to channeling in one of the subsequent strips. As a result, the incident beam was strongly spread because of opposite directions of the deflections. A modified multi-strip deflector produced by periodic grooves on the surface of a thick silicon plate was used for these measurements. This technique provides perfect mutual alignment between crystal strips. Such multi-strip deflector may be effective for collider beam halo collimation and a study is planned at the CERN SPS circulating beam.
|
|
|
AGATA Collaboration(Valiente-Dobon, J. J. et al), Perez-Vidal, R. M., Blasco Miquel, J., Civera, J. V., & Gadea, A. (2023). Conceptual design of the AGATA 2 pi array at LNL. Nucl. Instrum. Methods Phys. Res. A, 1049, 168040–14pp.
Abstract: The Advanced GAmma Tracking Array (AGATA) has been installed at Laboratori Nazionali di Legnaro (LNL), Italy. In this installation, AGATA will consist, at the beginning, of 13 AGATA triple clusters (ATCs) with an angular coverage of 1n,and progressively the number of ATCs will increase up to a 2 pi angular coverage. This setup will exploit both stable and radioactive ion beams delivered by the Tandem-PIAVE-ALPI accelerator complex and the SPES facility. The new implementation of AGATA at LNL will be used in two different configurations, firstly one coupled to the PRISMA large-acceptance magnetic spectrometer and lately a second one at Zero Degrees, along the beam line. These two configurations will allow us to cover a broad physics program, using different reaction mechanisms, such as Coulomb excitation, fusion-evaporation, transfer and fission at energies close to the Coulomb barrier. These setups have been designed to be coupled with a large variety of complementary detectors such as charged particle detectors, neutron detectors, heavy-ion detectors, high-energy gamma-ray arrays, cryogenic and gasjet targets and the plunger device for lifetime measurements. We present in this paper the conceptual design, characteristics and performance figures of this implementation of AGATA at LNL.
|
|
|
Babeluk, M. et al, & Marinas, C. (2023). CMOS MAPS upgrade for the Belle II Vertex Detector. Nucl. Instrum. Methods Phys. Res. A, 1048, 168015–5pp.
Abstract: The success of the Belle II experiment in Japan relies on the very high instantaneous luminosity, close to 6x1035 cm-2 s-1, expected from the SuperKEKB collider. The corresponding beam conditions at such luminosity levels generate large rates of background particles and creates stringent constraints on the vertex detector, adding to the physics requirements. Current prospects for the occupancy rates in the present vertex detector (VXD) at full luminosity fall close to the acceptable limits and bear large uncertainties. In this context, the Belle II collaboration is considering the possibility to install an upgraded VXD system around 2027 to provide a sufficient safety margin with respect to the expected background rate and possibly enhance tracking and vertexing performance. The VTX collaboration has started the design of a fully pixelated VXD, called VTX, based on fast and highly granular Depleted Monolithic Active Pixel Sensors (DMAPS) integrated on light support structures. The two main technical features of the VTX proposal are the usage of a single sensor type over all the layers of the system and the overall material budget below 2% of radiation length, compared to the current VXD which has two different sensor technologies and about 3% of radiation length. A dedicated sensor (OBELIX), taylored to the specific needs of Belle II, is under development, evolving from the existing TJ-Monopix2 sensor. The time-stamping precision below 100 ns will allow all VTX layers to take part in the track finding strategy contrary to the current situation. The first two detection layers are designed according to a self-supported all-silicon ladder concept, where 4 contiguous sensors are diced out of a wafer, thinned and interconnected with post-processed redistribution layers. The outermost detection layers follow a more conventional approach with a cold plate and carbon fibre support structure, and light flex cables interconnecting the sensors. This document will review the context, technical details and development status of the proposed Belle II VTX.
|
|
|
Mendoza, E., Alcayne, V., Cano-Ott, D., Gonzalez-Romero, E., Martinez, T., de Rada, A. P., et al. (2023). Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique. Nucl. Instrum. Methods Phys. Res. A, 1047, 167894–16pp.
Abstract: Neutron capture cross section measurements in time-of-flight facilities are usually performed by detecting the prompt 7-rays emitted in the capture reactions. One of the difficulties to be addressed in these measurements is that the emitted 7-rays may change with the neutron energy, and therefore also the detection efficiency. To deal with this situation, many measurements use the so called Total Energy Detection (TED) technique, usually in combination with the Pulse Height Weighting Technique (PHWT). With it, it is sought that the detection efficiency depends only on the total energy of the 7-ray cascade, which does not vary much with the neutron energy. This technique was developed in the 1960s and has been used in many neutron capture experiments to date. One of the requirements of the technique is that 7-ray detectors have a low efficiency. This has meant that the PHWT has been used with experimental setups with low detection efficiencies. However, this condition does not have to be fulfilled by the experimental system as a whole. The main goal of this work is to show that it is possible to measure with a high efficiency detection system that uses the PHWT, and how to analyze the measured data.
|
|
|
Real, D., & Calvo, D. (2022). Production requirements and functional tests of the KM3NeT Digital Optical Module Power Board. Nucl. Instrum. Methods Phys. Res. A, 1042, 167426–3pp.
Abstract: The KM3NeT research facility is being built in the Mediterranean Sea. It consists of matrices of optical detectors, the so-called Digital Optical Module. Each of this elementary detector holds a set of 31 small-area photomultipliers, which detect the Cherenkov light generated by secondary particles produced in neutrino interactions. It includes also the acquisition electronics and the power board which supplies both, the acquisition electronics and the photomultipliers. The production of electronics boards needs to have a high quality and reliability level as it is going to be deployed for more than ten years without any maintenance possible. This work presents the requirements and the qualification tests being implemented in order to increase the reliability of the Power Board of the acquisition electronics of KM3NeT during the mass production. At the moment, more than one thousand board have been produced. Results on the production of the boards, including the production yield is presented. From the already produced boards, more than 350 have been already deployed and are operative in the detectors.
|
|
|
Hueso-Gonzalez, F., Casaña Copado, J. V., Fernandez Prieto, A., Gallas Torreira, A., Lemos Cid, E., Ros Garcia, A., et al. (2022). A dead-time-free data acquisition system for prompt gamma-ray measurements during proton therapy treatments. Nucl. Instrum. Methods Phys. Res. A, 1033, 166701–9pp.
Abstract: In cancer patients undergoing proton therapy, a very intense secondary radiation is produced during the treatment, which lasts around one minute. About one billion prompt gamma-rays are emitted per second, and their detection with fast scintillation detectors is useful for monitoring a correct beam delivery. To cope with the expected count rate and pile-up, as well as the scarce statistics due to the short treatment duration, we developed an eidetic data acquisition system capable of continuously digitizing the detector signal with a high sampling rate and without any dead time. By streaming the fully unprocessed waveforms to the computer, complex pile-up decomposition algorithms can be applied and optimized offline. We describe the data acquisition architecture and the multiple experimental tests designed to verify the sustained data throughput speed and the absence of dead time. While the system is tailored for the proton therapy environment, the methodology can be deployed in any other field requiring the recording of raw waveforms at high sampling rates with zero dead time.
|
|
|
Mistry, A. K. et al, Tain, J. L., Agramunt, J., Algora, A., Guadilla, V., Morales, A. I., et al. (2022). The DESPEC setup for GSI and FAIR. Nucl. Instrum. Methods Phys. Res. A, 1033, 166662–18pp.
Abstract: The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr3(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path.
|
|
|
Chiera, N. M., Maugeri, E. A., Danilov, I., Balibrea-Correa, J., Domingo-Pardo, C., Koster, U., et al. (2022). Preparation of PbSe targets for Se-79 neutron capture cross section studies. Nucl. Instrum. Methods Phys. Res. A, 1029, 166443–7pp.
Abstract: A methodology for the production of PbSe targets for Se-79 neutron capture cross section studies is presented. PbSe material was synthesized by direct reaction of its constituents at high temperature, and characterized by X-ray diffraction. Thin PbSe targets, produced for cross section experiments with the surrogate reaction method, were obtained by applying a physical vapor deposition technique, and their morphology and composition were analyzed by X-ray fluorescence, Scanning Electron Microscopy, and Energy dispersive X-ray spectroscopy. (PbSe)-Se-79 targets produced for cross section measurements with the Time of Flight method were characterized by gamma-ray spectroscopy. Finally, a procedure for the recovery of Se from PbSe is suggested. The purity of the retrieved Se was determined with Inductively Coupled Plasma Optical Emission Spectroscopy.
|
|
|
Goasduff, A. et al, & Gadea, A. (2021). The GALILEO gamma-ray array at the Legnaro National Laboratories. Nucl. Instrum. Methods Phys. Res. A, 1015, 165753–15pp.
Abstract: GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.
|
|