Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). A study of the effect of molecular and aerosol conditions in the atmosphere on air fluorescence measurements at the Pierre Auger Observatory. Astropart Phys., 33(2), 108–129.
Abstract: The air fluorescence detector of the Pierre Auger Observatory is designed to perforin calorimetric measurements of extensive air showers created by Cosmic rays of above 10(18) eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group Of monitoring instruments to record atmospheric conditions across the detector site, ail area exceeding 3000 km(2). The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierre Auger Observatory since the start of regular operations in 2004, and includes a discussion of the impact of these measurements oil air shower reconstructions. Between 10(18) and 10(20) eV, the systematic Uncertainties due to all atmospheric effects increase from 4% to 8% in measurements of shower energy, and 4 g cm(-2) to 8 g cm(-2) in measurements of the shower maximum.
|
Freitas, E. D. C., Monteiro, C. M. B., Ball, M., Gomez-Cadenas, J. J., Lopes, J. A. M., Lux, T., et al. (2010). Secondary scintillation yield in high-pressure xenon gas for neutrinoless double beta decay (0 nu beta beta) search. Phys. Lett. B, 684(4-5), 205–210.
Abstract: The search for neutrinoless double beta decay (0 nu beta beta) is an important topic in contemporary physics with many active experiments. New projects are planning to use high-pressure xenon gas as both source and detection medium. The secondary scintillation processes available in noble gases permit large amplification with negligible statistical fluctuations, offering the prospect of energy resolution approaching the Fano factor limit. This Letter reports results for xenon secondary scintillation yield, at room temperature, as a function of electric field in the gas scintillation gap for pressures ranging from 2 to 10 bar. A Large Area Avalanche Photodiode (LAAPD) collected the VUV secondary scintillation produced in the gas. X-rays directly absorbed in the LAAPD are used as a reference for determining the number of charge carriers produced by the scintillation pulse and, hence, the number of photons impinging the LAAPD. The number of photons produced per drifting electron and per kilovolt, the so-called scintillation amplification parameter, displays a small increase with pressure, ranging from 141 +/- 6 at 2 bar to 170 +/- 10 at 8 bar. In our setup, this Parameter does not increase above 8 bar due to nonnegligible electron attachment. The results are in good agreement with those presented in the literature in the 1 to 3 bar range. The increase of the scintillation amplification parameter with pressure for high gas densities has been also observed in former work at cryogenic temperatures.
|
Gomez Dumm, D., Roig, P., Pich, A., & Portoles, J. (2010). tau -> pi pi pi nu(tau) decays and the a(1)(1260) off-shell width revisited. Phys. Lett. B, 685(2-3), 158–164.
Abstract: The tau -> pi pi pi nu(tau) decay is driven by the hadronization of the axial-vector current. Within the resonance chiral theory, and considering the large-N-C expansion, this process has been studied in Ref. [1] (D. Gomez Dumm, A. Pich, J. Portoles, 2004). In the light of later developments we revise here this previous work by including a new off-shell width for the lightest a(1) resonance that provides a good description of the tau -> pi pi pi nu(tau) spectrum and branching ratio. We also consider the role of the rho(1450) resonance in these observables. Thus we bring in an overall description of the tau -> pi pi pi nu(tau) process in excellent agreement with our present experimental knowledge.
|
Cirigliano, V., Jenkins, J. P., & Gonzalez-Alonso, M. (2010). Semileptonic decays of light quarks beyond the Standard Model. Nucl. Phys. B, 830(1-2), 95–115.
Abstract: We describe non-standard contributions to semileptonic processes in a model independent way in terms of in SU(2)(L) x U(1)(Y) invariant effective lagrangian at the weak scale, front which we derive the low-energy effective lagrangian governing muon and beta decays. We find that the deviation from Cabibbo universality, Delta(CKM) equivalent to vertical bar V-ud vertical bar(2) + vertical bar V-us vertical bar(2) + vertical bar V-ub vertical bar(2) – 1, receives contributions from four effective operators. The phenomenological bound Delta(CKM) = (-1 +/- 6) x 10(-4) provides strong constraints on all four operators, corresponding to art effective scale Lambda > 11 TeV (90% CL). Depending on the operator, this constraint is at the same level or better then the Z pole observables. Conversely, precision electroweak constraints alone would allow universality violations as large as Delta(CKM) = -0.01 (90% CL). An observed Delta(CKM) not equal 0 at this level Could be explained in terms of a single four-fermion operator which is relatively poorly constrained by electroweak precision measurements.
|
Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). Trigger and aperture of the surface detector array of the Pierre Auger Observatory. Nucl. Instrum. Methods Phys. Res. A, 613(1), 29–39.
Abstract: The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3 x 10(18) eV, for all zenith angles between 0 degrees and 60 degrees, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.
|