|
Tain, J. L., Algora, A., Agramunt, J., Guadilla, V., Jordan, M. D., Montaner-Piza, A., et al. (2015). A decay total absorption spectrometer for DESPEC at FAIR. Nucl. Instrum. Methods Phys. Res. A, 803, 36–46.
Abstract: This paper presents the design of a total absorption gamma-ray spectrometer for the determination of beta-decay intensity distributions of exotic nuclear species at the focal plane of the FAIR-NUSTAR Super Fragment Separator. The spectrometer is a key instrument in the DESPEC experiment and the proposed implementation follows extensive design studies and prototype tests. Two options were contemplated, based on Nal(TI) and LaBr3:Ce inorganic scintillation crystals respectively. Monte Carlo simulations and technical considerations determined the optimal configurations consisting of sixteen 15 x 15 x 25 cm(3) crystals for the Nal(Tl) option and one hundred and twenty-eight 5.5 x 5.5 x 11 cm(3) crystals for the LaBr3:Ce option. Minimization of dead material was crucial for maximizing the spectrometer full-energy peak efficiency. Module prototypes were build to verify constructional details and characterize their performance. The measured energy and timing resolution was found to agree rather well with estimates based on simulations of scintillation light transport and collection. The neutron sensitivity of the spectrometer, important when measuring beta-delayed neutron emitters, was investigated by means of Monte Carlo simulations.
|
|
|
n_TOF Collaboration(Bacak, M. et al), Domingo-Pardo, C., & Tain, J. L. (2020). A compact fission detector for fission-tagging neutron capture experiments with radioactive fissile isotopes. Nucl. Instrum. Methods Phys. Res. A, 969, 163981–10pp.
Abstract: In the measurement of neutron capture cross-sections of fissile isotopes, the fission channel is a source of background which can be removed efficiently using the so-called fission-tagging or fission-veto technique. For this purpose a new compact and fast fission chamber has been developed. The design criteria and technical description of the chamber are given within the context of a measurement of the U-233(n, gamma) cross-section at the nTOF facility at CERN, where it was coupled to the nTOF Total Absorption Calorimeter. For this measurement the fission detector was optimized for time resolution, minimization of material in the neutron beam and for alpha-fission discrimination. The performance of the fission chamber and its application as a fission tagging detector are discussed.
|
|
|
n_TOF Collaboration(Tagliente, G. et al.), Domingo-Pardo, C., & Tain, J. L. (2011). (96)Zr(n,gamma) measurement at the n_TOF facility at CERN. Phys. Rev. C, 84(5), 055802–8pp.
Abstract: The (n,gamma) cross section of (96)Zr has been investigated at the CERN n_TOF spallation neutron source. High-resolution time-of-flight measurements using an enriched ZrO(2) sample allowed us to analyze 15 resonances below 40 keV with improved accuracy. On average, the capture widths were found to be 25% smaller than reported in earlier experiments. If complemented with the contribution by direct radiative capture, the derived Maxwellian averaged cross sections are consistent with activation data at kT = 25 keV. The present results confirm the astrophysical implications for the s-process branching at (95)Zr.
|
|
|
n_TOF Collaboration(Paradela, C. et al), Domingo-Pardo, C., Plag, R., Plompen, A., & Tain, J. L. (2011). (237)Np(n,f) Cross Section: New Data and Present Status. J. Korean Phys. Soc., 59(2), 1908–1911.
Abstract: In this document, we present the final result obtained at the nTOF experiment; for the neutron-induced fission cross section of the (237)Np, from the fission threshold up to 1 GeV. The method applied to get tins result is briefly discussed. nTOF data are compared to the last experimental measurements using other TOF facilities or the surrogate method, reported experiments performed with monoenergetic sources and the FISCAL systematic, including a discussion about the existing discrepancies.
|
|