|
Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). Trigger and aperture of the surface detector array of the Pierre Auger Observatory. Nucl. Instrum. Methods Phys. Res. A, 613(1), 29–39.
Abstract: The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3 x 10(18) eV, for all zenith angles between 0 degrees and 60 degrees, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.
|
|
|
Aristizabal Sierra, D., Bazzocchi, F., de Medeiros Varzielas, I., Merlo, L., & Morisi, S. (2010). Tri/Bi-maximal lepton mixing and leptogenesis. Nucl. Phys. B, 827(1-2), 34–58.
Abstract: In models with flavour symmetries added to the gauge group of the Standard Model the CP-violating asymmetry necessary for leptogenesis may be related with low-energy parameters. A particular case of interest is when the flavour symmetry produces exact Tri/Bi-maximal lepton mixing leading to a vanishing CP-violating asymmetry. In this paper we present a model-independent discussion that confirms this always occurs for unflavoured leptogenesis in type I see-saw scenarios, noting however that Tri/Bi-maximal mixing does not imply a vanishing asymmetry in general scenarios where there is interplay between type I and other see-saws. We also consider a specific model where the exact Tri/Bi-maximal mixing is lifted by corrections that can be parametrised by a small number of degrees of freedom and analyse in detail the existing link between low and high-energy parameters – focusing on how the deviations from Tri/Bi-maximal are connected to the parameters governing leptogenesis.
|
|
|
Bizzeti, P. G. et al, & Gadea, A. (2010). Transition probabilities in the X(5) candidate Ba-122. Phys. Rev. C, 82(5), 054311–10pp.
Abstract: To investigate the possible X(5) character of Ba-122, suggested by the ground-state band energy pattern, the lifetimes of the lowest yrast states of Ba-122 have been measured, via the recoil distance Doppler-shift method. The relevant levels have been populated by using the Cd-108(O-16,2n)Ba-122 and the Sn-112(C-13, 3n)Ba-122 reactions. The B(E2) values deduced in the present work are compared to the predictions of the X(5) model and to calculations performed in the framework of the IBA-1 and IBA-2 models.
|
|
|
Lledo, M. A., & Sommovigo, L. (2010). Torsion formulation of gravity. Class. Quantum Gravity, 27(6), 065014–16pp.
Abstract: We explain precisely what it means to have a connection with torsion as a solution of the Einstein equations. While locally the theory remains the same, the new formulation allows for topologies that would have been excluded in the standard formulation of gravity. In this formulation it is possible to couple arbitrary torsion to gauge fields without breaking the gauge invariance.
|
|
|
Studen, A., Burdette, D., Chesi, E., Cindro, V., Clinthorne, N. H., Cochran, E., et al. (2010). Timing performance of the silicon PET insert probe. Radiat. Prot. Dosim., 139(1-3), 199–203.
Abstract: Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 256 square pads (1.4 mm side), coupled with two VATAGP7s, application-specific integrated circuits. The detector material and electronics are the same that will be used for the final probe. The model was exposed to 511 keV annihilation photons from an Na-22 source, and a scintillator (LYSO)-PMT assembly was used as a timing reference. Results were compared with the simulation, consisting of four parts: (i) GEANT4 implemented realistic tracking of electrons excited by annihilation photon interactions in silicon, (ii) calculation of propagation of secondary ionisation (electron-hole pairs) in the sensor, (iii) estimation of the shape of the current pulse induced on surface electrodes and (iv) simulation of the first electronics stage. A very good agreement between the simulation and the measurements were found. Both indicate reliable performance of the final probe at timing windows down to 20 ns.
|
|