Garcilazo, H., Valcarce, A., & Vijande, J. (2020). Xi(-)t quasibound state instead of Lambda Lambda nn bound state. Chin. Phys. C, 44(2), 024102–7pp.
Abstract: The coupled Lambda Lambda nn – Xi-pnn system was studied to investigate whether the inclusion of channel coupling is able to bind the Lambda Lambda nn system. We use a separable potential three-body model of the coupled Lambda Lambda nn – Xi-pnn system and a variational four-body calculation with realistic interactions. Our results exclude the possibility of a bound state by a large margin. Instead, we found a Xi(-)t quasibound state above the Lambda Lambda nn threshold.
|
Gimenez-Alventosa, V., Ballester, F., & Vijande, J. (2016). VoxelMages: a general-purpose graphical interface for designing geometries and processing DICOM images for PENELOPE. Appl. Radiat. Isot., 118, 251–257.
Abstract: The design and construction of geometries for Monte Carlo calculations is an error-prone, time-consuming, and complex step in simulations describing particle interactions and transport in the field of medical physics. The software VoxelMages has been developed to help the user in this task. It allows to design complex geometries and to process DICOM image files for simulations with the general-purpose Monte Carlo code PENELOPE in an easy and straightforward way. VoxelMages also allows to import DICOM-RT structure contour information as delivered by a treatment planning system. Its main characteristics, usage and performance benchmarking are described in detail.
|
Richard, J. M., Valcarce, A., & Vijande, J. (2020). Very Heavy Flavored Dibaryons. Phys. Rev. Lett., 124(21), 212001–4pp.
Abstract: We explore the possibility of very heavy dibaryons with three charm quarks and three beauty quarks, bbbccc, using a constituent model which should lead to the correct solution in the limit of hadrons made of heavy quarks. The six-body problem is treated rigorously, in particular taking into account the orbital, color, and spin mixed-symmetry components of the wave function. Unlike a recent claim based on lattice QCD, no bound state is found below the lowest dissociation threshold.
|
Vijande, J., & Valcarce, A. (2014). Unraveling the pattern of the XYZ mesons. Phys. Lett. B, 736, 325–328.
Abstract: We present a plausible mechanism for the origin of the XYZ mesons in the heavy meson spectra within a standard quark-model picture. We discuss the conditions required for the existence of four-quark bound states or resonances contributing to the heavy meson spectra, being either compact or molecular. We concentrate on charmonium and bottomonium spectra, where several new states, difficult to understand as simple quark-antiquark pairs, have been reported by different experimental collaborations. The pivotal role played by entangled meson-meson thresholds is emphasized.
|
Gimenez-Alventosa, V., Vijande, J., Ballester, F., & Perez-Calatayud, J. (2016). Transit dose comparisons for Co-60 and Ir-192 HDR sources. J. Radiol. Prot., 36(4), 858–864.
Abstract: The goal of this study is to evaluate the ambient dose due to the transit of high dose rate (HDR) Co-60 sources along a transfer tube as compared to Ir-192 ones in a realistic clinical scenario. This goal is accomplished by evaluating air-kerma differences with Monte Carlo calculations using PENELOPE2011. Scatter from both the afterloader and the patient was not taken into account. Two sources, mHDR-v2 and Flexisource Co-60, (Elekta Brachytherapy, Veenendaal, the Netherlands) have been considered. These sources were simulated within a standard transfer tube located in an infinite air phantom. The movement of the source was included by displacing their positions along the connecting tube from z = – 75 cm to z = + 75 cm and combining them. Since modern afterloaders like Flexitron (Elekta) or Saginova (BEBIG GmbH) are able to use equally 192Ir and 60Co sources, it was assumed that both sources are displaced with equal speed. Typical HDR source activity content values were provided by the manufacturer. 2D distributions were obtained with type-A uncertainties (k = 2) less than 0.01%. From those, the air-kerma ratio Co-60/Ir-192 was evaluated weighted by their corresponding typical activities. It was found that it varies slowly with distance (less than 10% variation at 75 cm) but strongly in time due to the shorter half-life of the 192Ir (73.83 d). The maximum ratio is located close to the tube. It reaches a value of 0.57 when the typical activity of the sources at the time when they were installed by the vendor was used. Such ratio increases up to 1.28 at the end of the recommended working life (90 d) of the Ir-192 source. Co-60/Ir-192 air-kerma ratios are almost constant (0.51-0.57) in the vicinity of the source-tube with recent installed sources. Nevertheless, air-kerma ratios increase rapidly (1.15-1.29) whenever the Ir-192 is approaching the end of its life. In case of a medical event requiring the medical staff to access the treatment room, these ratios indicate that the dosimetric impact on the medical team will be lower, with a few exceptions, in the case of Co-60-based HDR brachytherapy as compared to Ir-192-based one when typical air-kerma strength values are considered.
|