Garzon, E. J., & Xie, J. J. (2015). Effects of a Nc(c)over-bar* resonance with hidden charm in the pi(-)p -> D-Sigma(+)(c) reaction near threshold. Phys. Rev. C, 92(3), 035201–4pp.
Abstract: We study the effect of a hidden charm nuclear excited state N-c (c) over bar* in the pi(-)p -> D-Sigma(+)(c) reaction near threshold using an effective Lagrangian approach. We calculate the background contribution of the t and u channels by the D*(0) vector meson exchange and Sigma(++)(c) intermediate state, respectively. We show that the consideration of a N-c (c) over bar* resonance provides an enhancement of the total cross section close to the reaction threshold. We also evaluate the differential cross section for different energies and we study the angle dependence. It is expected that our model calculations will be tested in future experiments.
|
Tain, J. L. et al, Valencia, E., Algora, A., Agramunt, J., Rubio, B., Estevez, E., et al. (2015). Enhanced gamma-Ray Emission from Neutron Unbound States Populated in beta Decay. Phys. Rev. Lett., 115(6), 062502–5pp.
Abstract: Total absorption spectroscopy is used to investigate the beta-decay intensity to states above the neutron separation energy followed by gamma-ray emission in Br-87,Br-88 and Rb-94. Accurate results are obtained thanks to a careful control of systematic errors. An unexpectedly large. intensity is observed in all three cases extending well beyond the excitation energy region where neutron penetration is hindered by low neutron energy. The gamma branching as a function of excitation energy is compared to Hauser-Feshbach model calculations. For Br-87 and Br-88 the gamma branching reaches 57% and 20%, respectively, and could be explained as a nuclear structure effect. Some of the states populated in the daughter can only decay through the emission of a large orbital angular momentum neutron with a strongly reduced barrier penetrability. In the case of neutron-rich Rb-94 the observed 4.5% branching is much larger than the calculations performed with standard nuclear statistical model parameters, even after proper correction for fluctuation effects on individual transition widths. The difference can be reconciled by introducing an enhancement of 1 order of magnitude in the photon strength to neutron strength ratio. An increase in the photon strength function of such magnitude for very neutron-rich nuclei, if it proves to be correct, leads to a similar increase in the (n, gamma) cross section that would have an impact on r process abundance calculations.
|
del Rio, A., & Navarro-Salas, J. (2015). Equivalence of adiabatic and DeWitt-Schwinger renormalization schemes. Phys. Rev. D, 91(6), 064031–14pp.
Abstract: We prove that adiabatic regularization and DeWitt-Schwinger point-splitting provide the same result when renormalizing expectation values of the stress-energy tensor for spin-1/2 fields. This generalizes the equivalence found for scalar fields, which is here recovered in a different way. We also argue that the coincidence limit of the DeWitt-Schwinger proper time expansion of the two-point function agrees exactly with the analogous expansion defined by the adiabatic regularization method at any order (for both scalar and spin-1/2 fields). We also illustrate the power of the adiabatic method to compute higher order DeWitt coefficients in Friedmann-Lemaitre-Robertson-Walker Universes.
|
Grkovski, M., Brzezinski, K., Cindro, V., Clinthorne, N. H., Kagan, H., Lacasta, C., et al. (2015). Evaluation of a high resolution silicon PET insert module. Nucl. Instrum. Methods Phys. Res. A, 788, 86–94.
Abstract: Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm(2) pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (20) geometry with a Jaszczak phantom (rod diameters of 12-4.8 mm) Filled with F-18-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).
|
Palomo, R., Pujades, M. C., Gimeno-Olmos, J., Carmona, V., Lliso, F., Candela-Juan, C., et al. (2015). Evaluation of lens absorbed dose with Cone Beam IGRT procedures. J. Radiol. Prot., 35(4), N33–N41.
Abstract: The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v. 1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to the OBI systems of the Clinac iX and the TrueBeam were 0.71 +/- 0.07 mGy/CBCT and 0.70 +/- 0.08 mGy/CBCT, respectively. The extra absorbed dose received by the eye lenses due to one CBCT acquisition with the studied protocol is far below the 500 mGy threshold established by ICRP for cataract formation (ICRP 2011 Statement on Tissue Reactions). However, the incremental effect of several CBCT acquisitions during the whole treatment should be taken into account.
|