|
Moreira, A. R. P., Belchior, F. M., Maluf, R. V., & Almeida, C. A. S. (2023). Bulk fields localization on thick string-like brane in f(T) gravity. Eur. Phys. J. Plus, 138(8), 730–15pp.
Abstract: This paper aims to investigate the influence of torsion on bulk fields in the codimension two thick brane in f(T) modified teleparallel gravity. It is shown that the brane supports the localization of gauge field zero mode without an extra coupling. However, Kalb-Ramond and fermionic fields require a suitable coupling. Then, it is proposed a geometrical coupling based on results in 5D thick brane in modified teleparallel gravities. The Kalb-Ramond field is coupled to torsion scalar T through a gauge-invariant interaction. For the case of fermionic fields, we study the Dirac fermions and gravitino with a derivative geometrical coupling. For all of the fields, it obtained massive and resonant modes by employing the Schodinger-like approach.
|
|
|
ATLAS Collaboration(Aad, G. et al), Amos, K. R., Aparisi Pozo, J. A., Bailey, A. J., Bouchhar, N., Cabrera Urban, S., et al. (2023). Calibration of the light-flavour jet mistagging efficiency of the b-tagging algorithms with Z plus jets events using 139 fb<SUP>-1</SUP> of ATLAS proton-proton collision data at √s=13 TeV. Eur. Phys. J. C, 83(8), 728–30pp.
Abstract: The identification of b-jets, referred to as b-tagging, is an important part of many physics analyses in the ATLAS experiment at the Large Hadron Collider and an accurate calibration of its performance is essential for high-quality physics results. This publication describes the calibration of the light-flavour jet mistagging efficiency in a data sample of proton-proton collision events at root s = 13 TeV corresponding to an integrated luminosity of 139 fb(-1). The calibration is performed in a sample of Z bosons produced in association with jets. Due to the low mistagging efficiency for light-flavour jets, a method which uses modified versions of the b-tagging algorithms referred to as flip taggers is used in this work. A fit to the jet-flavour-sensitive secondary-vertex mass is performed to extract a scale factor from data, to correct the light-flavour jet mistagging efficiency in Monte Carlo simulations, while simultaneously correcting the b-jet efficiency. With this procedure, uncertainties coming from the modeling of jets from heavy-flavour hadrons are considerably lower than in previous calibrations of the mistagging scale factors, where they were dominant. The scale factors obtained in this calibration are consistent with unity within uncertainties.
|
|
|
Viegas, R., Roser, J., Barrientos, L., Borja-Lloret, M., Casaña, J. V., Lopez, J. G., et al. (2023). Characterization of a Compton camera based on the TOFPET2 ASIC. Radiat. Phys. Chem., 202, 110507–11pp.
Abstract: The use of Compton cameras for medical imaging and its interest as a hadron therapy treatment monitoring has increased in the last decade with the development of silicon photomultipliers. MACACOp is a Compton camera prototype designed and assembled at the IRIS group of IFIC-Valencia. This Compton camera is based on monolithic Lanthanum (III) Bromide crystals and silicon photomultipliers, and employs the novel TOFPET2 ASIC as readout electronics. This system emerged as an alternative to MACACO II prototype, with the aim of improving its limited time resolution. To test the performance of the ASIC in a Compton camera setup, the prototype was characterized, both in laboratory and in-beam. A time resolution of 1.5 ns was obtained after time corrections, which improves greatly the performance of the MACACO II. Moreover, the results obtained at high photon energies demonstrate the ability of the system to obtain 1 mm displacements of the reconstructed spots. The results reinforce the potential of the system as a monitoring device for hadron therapy.
|
|
|
Latonova, V. et al, Bernabeu, J., Lacasta, C., Solaz, C., & Soldevila, U. (2023). Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation. Nucl. Instrum. Methods Phys. Res. A, 1050, 168119–5pp.
Abstract: The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb(-1) means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 center dot 10(15) MeVn(eq)/cm(2) and 0.66MGy, respectively, including a safety factor of 1.5. Radiation hard n(+)-in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n(+) implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. We discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.
|
|
|
Gomez Dumm, D., Noguera, S., & Scoccola, N. N. (2023). Charged meson masses under strong magnetic fields: Gauge invariance and Schwinger phases. Phys. Rev. D, 108(1), 016012–29pp.
Abstract: We study the role of the Schwinger phase (SP) that appears in the propagator of a charged particle in the presence of a static and uniform magnetic field (B) over right arrow. We first note that this phase cannot be removed by a gauge transformation; far from this, we show that it plays an important role in the restoration of the symmetries of the system. Next, we analyze the effect of SPs in the one-loop corrections to charged pion and rho meson self-energies. To carry out this analysis we consider first a simple form for the meson-quark interactions, and then we study the pi(+) and rho(-) propagators within the Nambu-Jona-Lasinio model, performing a numerical analysis of the B dependence of meson lowest energy states. For both pi(+) and rho(-) mesons, we compare the numerical results arising from the full calculation-in which SPs are included in the propagators, and meson wave functions correspond to states of definite Landau quantum number-and those obtained within alternative schemes in which SPs are neglected (or somehow eliminated) and meson states are described by plane waves of definite four-momentum.
|
|