Caballero-Folch, R. et al, Domingo-Pardo, C., Agramunt, J., Algora, A., Rubio, B., & Tain, J. L. (2016). First Measurement of Several beta-Delayed Neutron Emitting Isotopes Beyond N=126. Phys. Rev. Lett., 117(1), 012501–6pp.
Abstract: The beta-delayed neutron emission probabilities of neutron rich Hg and Tl nuclei have been measured together with beta-decay half-lives for 20 isotopes of Au, Hg, Tl, Pb, and Bi in the mass region N greater than or similar to 126. These are the heaviest species where neutron emission has been observed so far. These measurements provide key information to evaluate the performance of nuclear microscopic and phenomenological models in reproducing the high-energy part of the beta-decay strength distribution. This provides important constraints on global theoretical models currently used in r-process nucleosynthesis.
|
|
|
n_TOF Collaboration(Amaducci, S. et al), Babiano-Suarez, V., Caballero-Ontanaya, L., Domingo-Pardo, C., Ladarescu, I., & Tain, J. L. (2021). First Results of the Ce-140(n,gamma)Ce-141 Cross-Section Measurement at n_TOF. Universe, 7(6), 200–11pp.
Abstract: An accurate measurement of the Ce-140(n,gamma) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the Ce-140 capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in Ce-140 to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the Ce-140 Maxwellian-averaged cross-section.
|
|
|
Magan, D. L. P., Caballero, L., Domingo-Pardo, C., Agramunt-Ros, J., Albiol, F., Casanovas, A., et al. (2016). First tests of the applicability of gamma-ray imaging for background discrimination in time-of-flight neutron capture measurements. Nucl. Instrum. Methods Phys. Res. A, 823, 107–119.
Abstract: In this work we explore for the first time the applicability of using gamma-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr3 scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a Au-197 sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.
|
|
|
n_TOF Collaboration(Calviani, M. et al), Domingo-Pardo, C., & Tain, J. L. (2011). Fission Cross-section Measurements of (233)U, (245)Cm and (241,243)Am at CERN n_TOF Facility. J. Korean Phys. Soc., 59(2), 1912–1915.
Abstract: Neutron-induced fission cross-sections of minor actinides have been measured using the nTOF white neutron source at CERN. Geneva, as part of a large experimental program aiming at collecting new data relevant for nuclear astrophysics and for the design of advanced reactor systems. The measurements at nTOF take advantage of the innovative features of the n_TOF facility, namely the wide energy range, high instantaneous neutron flux and good energy resolution. Final results on the fission cross-section of (233)U, (245)cm and (243)Am from thermal to 20 MeV are here reported, together with preliminary results for (241)Am. The measurement have been performed with a dedicated Fast Ionization Chamber (FIC), a fission fragment detector with a very high efficiency, relative to the very well known cross-section of (235)U, measured simultaneously with the same detector.
|
|
|
Caballero, L., Albiol, F., Corbi Bellot, A., Domingo-Pardo, C., Leganes Nieto, J. L., Agramunt Ros, J., et al. (2018). Gamma-ray imaging system for real-time measurements in nuclear waste characterisation. J. Instrum., 13, P03016–23pp.
Abstract: Acompact, portable and large field-of-viewgamma camera that is able to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities that enable its use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.
|
|