CDF Collaboration(Aaltonen, T. et al), Cabrera, S., & Cuenca Almenar, C. (2010). Study of multi-muon events produced in p (p)over-bar interactions at root s=1.96 TeV. Eur. Phys. J. C, 68(1-2), 109–118.
Abstract: We report the results of a study of multi-muon events produced at the Fermilab Tevatron collider and acquired with the CDF II detector using a dedicated dimuon trigger. The production cross section and kinematics of events in which both muon candidates are produced inside the beam pipe of radius 1.5 cm are successfully modeled by known processes which include heavy flavor production. In contrast, we are presently unable to fully account for the number and properties of the remaining events, in which at least one muon candidate is produced outside of the beam pipe, in terms of the same understanding of the CDF II detector, trigger, and event reconstruction.
|
ATLAS Collaboration(Abat, E. et al), Castillo Gimenez, V., Ferrer, A., Gonzalez, V., Higon-Rodriguez, E., Mitsou, V. A., et al. (2010). Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV. Nucl. Instrum. Methods Phys. Res. A, 621(1-3), 134–150.
Abstract: A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20-350 GeV and beam impact points and angles corresponding to pseudo-rapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit.
|
Ballester, F., Granero, D., Perez-Calatayud, J., Venselaar, J. L. M., & Rivard, M. J. (2010). Study of encapsulated Tm-170 sources for their potential use in brachytherapy. Med. Phys., 37(4), 1629–1637.
Abstract: Methods: The authors have assumed a theoretical Tm-170 cylindrical source encapsulated with stainless steel and typical dimensions taken from the currently available HDR Ir-192 brachytherapy sources. The dose-rate distribution was calculated for this source using the GEANT4 Monte Carlo (MC) code considering both photon and electron Tm-170 spectra. The AAPM TG-43 U1 brachytherapy dosimetry parameters were derived. To study general properties of Tm-170 encapsulated sources, spherical sources encapsulated with stainless steel and platinum were also studied. Moreover, the influence of small variations in the active core and capsule dimensions on the dosimetric characteristics was assessed. Treatment times required for a Tm-170 source were compared to those for Ir-192 and Yb-169 for the same contained activity. Results: Due to the energetic beta spectrum and the large electron yield, the bremsstrahlung contribution to the dose was of the same order of magnitude as from the emitted gammas and characteristic x rays. Moreover, the electron spectrum contribution to the dose was significant up to 4 mm from the source center compared to the photon contribution. The dose-rate constant Lambda of the cylindrical source was 1.23 cGy h(-1) U-1. The behavior of the radial dose function showed promise for applications in brachytherapy. Due to the electron spectrum, the anisotropy was large for r < 6 mm. Variations in manufacturing tolerances did not significantly influence the final dosimetry data when expressed in cGy h(-1) U-1. For typical capsule dimensions, maximum reference dose rates of about 0.2, 10, and 2 Gy min(-1) would then be obtained for Tm-170, Ir-192, and Yb-169, respectively, resulting in treatment times greater than those for HDR Ir-192 brachytherapy. Conclusions: The dosimetric characteristics of source designs exploiting the low photon energy of Tm-170 were studied for potential application in HDR-brachytherapy. Dose-rate distributions were obtained for cylindrical and simplified spherical Tm-170 source designs (stainless steel and platinum capsule materials) using MC calculations. Despite the high activity of Tm-170, calculated treatment times were much longer than for Ir-192.
|
BABAR Collaboration(del Amo Sanchez, P. et al), Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Study of B -> X gamma decays and determination of vertical bar V-td/V-ts vertical bar. Phys. Rev. D, 82(5), 051101–8pp.
Abstract: Using a sample of 471 x 10(6) B (B) over bar events collected with the BABAR detector, we study the sum of seven exclusive final states B -> X-s(d)gamma, where X-s(d) is a strange (nonstrange) hadronic system with a mass of up to 2.0 GeV/c(2). After correcting for unobserved decay modes, we obtain a branching fraction for b -> d gamma of (9.2 +/- 2.0(stat) +/- 2.3(syst) x 10(-6) in this mass range, and a branching fraction for b -> s gamma of (23.0 +/- 0.8(stat) +/- 3.0(syst) x 3.0(syst) x 10(-5) in the same mass range. We find B(b -> d gamma)/B(b -> s gamma) = 0.040 +/- 0.009(stat) +/- 0.010(syst), from which we determine vertical bar Vtd/Vts vertical bar = 0.199 +/- 0.022(stat) +/- 0.024(syst) +/- 0.002(th).
|
Deo, A. Y., Podolyak, Z., Walker, P. M., Algora, A., Rubio, B., Agramunt, J., et al. (2010). Structures of Po-201 and Rn-205 from EC/beta(+)-decay studies. Phys. Rev. C, 81(2), 024322–8pp.
Abstract: Several low-lying excited states in Rn-205(86)119 and Po-201(84)117 were identified for the first time following EC/beta(+) decay of Fr-205 and At-201, respectively, using gamma-ray and conversion electron spectroscopy at the CERN isotope separator on-line (ISOLDE) facility. The EC/beta(+) branch from Fr-205 was measured to be 1.5(2)%. The excited states of the daughter nuclei are understood in terms of the odd nucleon coupling to the neighboring even-even core. The neutron single-particle energies of the p(3/2) orbital relative to the f(5/2) ground state in Rn-205, and the f(5/2) orbital relative to the p(3/2) ground state in Po-201, were determined to be 31.4(2) and 5.7(3) keV, respectively. We tentatively identify a 13/2(+) isomeric level at 657.1(5) keV in Rn-205. The systematic behavior of the 13/2(+) and 3/2(-) levels is also discussed.
|