|
KM3NeT Collaboration(Aiello, S. et al), Alves Garre, S., Calvo, D., Carretero, V., Colomer, M., Corredoira, I., et al. (2021). Architecture and performance of the KM3NeT front-end firmware. J. Astron. Telesc. Instrum. Syst., 7(1), 016001–24pp.
Abstract: The KM3NeT infrastructure consists of two deep-sea neutrino telescopes being deployed in the Mediterranean Sea. The telescopes will detect extraterrestrial and atmospheric neutrinos by means of the incident photons induced by the passage of relativistic charged particles through the seawater as a consequence of a neutrino interaction. The telescopes are configured in a three-dimensional grid of digital optical modules, each hosting 31 photomultipliers. The photomultiplier signals produced by the incident Cherenkov photons are converted into digital information consisting of the integrated pulse duration and the time at which it surpasses a chosen threshold. The digitization is done by means of time to digital converters (TDCs) embedded in the field programmable gate array of the central logic board. Subsequently, a state machine formats the acquired data for its transmission to shore. We present the architecture and performance of the front-end firmware consisting of the TDCs and the state machine.
|
|
|
Boucenna, S. M., Valle, J. W. F., & Vicente, A. (2015). Are the B decay anomalies related to neutrino oscillations? Phys. Lett. B, 750, 367–371.
Abstract: Neutrino oscillations are solidly established, with a hint of CP violation just emerging. Similarly, there are hints of lepton universality violation in b -> s transitions at the level of 2.6 sigma. By assuming that the unitary transformation between weak and mass charged leptons equals the leptonic mixing matrix measured in neutrino oscillation experiments, we predict several lepton flavor violating (LFV) B meson decays. We are led to the tantalizing possibility that some LFV branching ratios for B decays correlate with the leptonic CP phase delta characterizing neutrino oscillations. Moreover, we also consider implications for l(i) -> l(j)l(k)l(k) decays.
|
|
|
Pavon Valderrama, M., Xie, J. J., & Nieves, J. (2012). Are there three Xi (1950) states? Phys. Rev. D, 85(1), 017502–5pp.
Abstract: Different experiments on hadron spectroscopy have long suspected the existence of several cascade states in the 1900-2000 MeV region. They are usually labeled under the common name of Xi (1950). As we argue here, there are also theoretical reasons supporting the idea of several Xi (1950) resonances. In particular, we propose the existence of three Xi (1950) states: one of these states would be part of a spinparity 1/2(-) decuplet and the other two probably would belong to the 5/2(+) and 5/2(-) octets. We also identify which decay channels are more appropriate for the detection of each of the previous states.
|
|
|
Drewes, M., Garbrecht, B., Hernandez, P., Kekic, M., Lopez-Pavon, J., Racker, J., et al. (2018). ARS leptogenesis. Int. J. Mod. Phys. A, 33(5-6), 1842002–46pp.
Abstract: We review the current status of the leptogenesis scenario originally proposed by Akhmedov, Rubakov and Smirnov (ARS). It takes place in the parametric regime where the right-handed neutrinos are at the electroweak scale or below and the CP-violating effects are induced by the coherent superposition of different right-handed mass eigenstates. Two main theoretical approaches to derive quantum kinetic equations, the Hamiltonian time evolution as well as the Closed-Time-Path technique are presented, and we discuss their relations. For scenarios with two right-handed neutrinos, we chart the viable parameter space. Both, a Bayesian analysis, that determines the most likely configurations for viable leptogenesis given different variants of flat priors, and a determination of the maximally allowed mixing between the light, mostly left-handed, and heavy, mostly right-handed, neutrino states are discussed. Rephasing invariants are shown to be a useful tool to classify and to understand various distinct contributions to ARS leptogenesis that can dominate in different parametric regimes. While these analyses are carried out for the parametric regime where initial asymmetries are generated predominantly from lepton-number conserving, but flavor violating effects, we also review the contributions from lepton-number violating operators and identify the regions of parameter space where these are relevant.
|
|
|
Candela-Juan, C., Ballester, F., Perez-Calatayud, J., & Vijande, J. (2015). Assaying multiple I-125 seeds with the well-ionization chamber SourceCheck(4 Pi) 33005 and a new insert. J. Contemp. Brachytherapy, 7(6), 492–496.
Abstract: Purpose: To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck(4 Pi) 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten I-125 seeds with one single measurement instead of measuring each seed individually. Material and methods: The material required is: a) the SourceCheck(4 Pi) 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S-K of one single seed at a time; b) a newly designed insert that accommodates ten seeds in one column, which allows measuring the mean S-K of the ten seeds in one single measurement; and c) a container with ten seeds from the same batch and class of the seeds used for the patient implant, and a set of nine non-radioactive seeds.The new insert is characterized by determining its calibration coefficient, used to convert the reading of the well-chamber when ten seeds are measured to their mean S-K. The proposed method is validated by comparing the mean S-K of the ten seeds obtained from the new insert with the individual measurement of S-K of each seed, evaluated with the PTW insert. Results: The ratio between the calibration coefficient of the new insert and the calibration coefficient of the PTW insert for the SourceCheck(4 Pi) 33005 is 1.135 +/- 0.007 (k = 1). The mean S-K of a set of ten seeds evaluated with this new system is in agreement with the mean value obtained from measuring independently the S-K of each seed. Conclusions: The new insert and procedure allow evaluating the mean S-K of ten seeds prior to the implant in a single measurement. The method is faster and more efficient from radiation protection point of view than measuring the individual S-K of each seed.
|
|