|
Records |
Links |
|
Author |
AGATA Collaboration; Doncel, M.; Quintana, B.; Gadea, A.; Recchia, F.; Farnea, E. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title ![sorted by Title field, descending order (down)](img/sort_desc.gif) |
Background rejection capabilities of a Compton imaging telescope setup with a DSSD Ge planar detector and AGATA |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
648 |
Issue |
|
Pages |
S131-S134 |
|
|
Keywords |
gamma-Spectroscopy; Gamma tracking; Imaging; Position-sensitive germanium detectors |
|
|
Abstract |
In this work, we show the first Monte Carlo results about the performance of the Ge array which we propose for the DESPEC experiment at FAIR, when the background algorithm developed for AGATA is applied. The main objective of our study is to characterize the capabilities of the gamma-spectroscopy system, made up of AGATA detectors in a semi-spherical distribution covering a 1 pi solid angle and a set of planar Ge detectors in a daisy configuration, to discriminate between gamma sources placed at different locations. |
|
|
Address |
[Doncel, M.; Quintana, B.] Univ Salamanca, Lab Radiac Ionizantes, E-37008 Salamanca, Spain, Email: doncel@usal.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000305376900035 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1071 |
|
Permanent link to this record |
|
|
|
|
Author |
Constantinou, M.; Dimopoulos, P.; Frezzotti, R.; Jansen, K.; Gimenez, V.; Lubicz, V.; Mescia, F.; Panagopoulos, H.; Papinutto, M.; Rossi, G.C.; Simula, S.; Skouroupathis, A.; Stylianou, F.; Vladikas, A. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title ![sorted by Title field, descending order (down)](img/sort_desc.gif) |
B-K-parameter from N-f=2 twisted mass lattice QCD |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Physical Review D |
Abbreviated Journal |
Phys. Rev. D |
|
|
Volume |
83 |
Issue |
1 |
Pages |
014505 - 20pp |
|
|
Keywords |
|
|
|
Abstract |
We present an unquenched N-f = 2 lattice computation of the B-K parameter which controls K-0 – (K) over bar (0) oscillations. A partially quenched setup is employed with two maximally twisted dynamical (sea) light Wilson quarks, and valence quarks of both the maximally twisted and the Osterwalder-Seiler variety. Suitable combinations of these two kinds of valence quarks lead to a lattice definition of the B-K parameter which is both multiplicatively renormalizable and O(a) improved. Employing the nonperturbative RI-MOM scheme, in the continuum limit and at the physical value of the pion mass we get B-K(RGI) = 0.729 +/- 0.030, a number well in line with the existing quenched and unquenched determinations. |
|
|
Address |
[Constantinou, M.; Panagopoulos, H.; Skouroupathis, A.; Stylianou, F.] Univ Cyprus, Dept Phys, CY-1678 Nicosia, Cyprus |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1550-7998 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000286761700002 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
576 |
|
Permanent link to this record |
|
|
|
|
Author |
Jung, M.; Pich, A.; Tuzon, P. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title ![sorted by Title field, descending order (down)](img/sort_desc.gif) |
B(bar) -> X_s gamma rate and CP asymmetry within the aligned two-Higgs-doublet model |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Physical Review D |
Abbreviated Journal |
Phys. Rev. D |
|
|
Volume |
83 |
Issue |
7 |
Pages |
074011 - 8pp |
|
|
Keywords |
|
|
|
Abstract |
In the two-Higgs-doublet model the alignment of the Yukawa matrices in flavor space guarantees the absence of flavor-changing neutral currents at tree level, while introducing new sources for CP violation parametrized in a very economical way [Antonio Pich and Paula Tuzon, Phys. Rev. D 80, 091702 (2009)]. This implies a potentially large influence in a number of processes, b -> s gamma being a prominent example where rather high experimental and theoretical precision meet. We analyze the CP rate asymmetry in this inclusive decay and determine the resulting constraints on the model parameters. We demonstrate the compatibility with previously obtained limits [Martin Jung, Antonio Pich, and Paula Tuzon, J. High Energy Phys. 11 (2010) 003]. Moreover, we extend the phenomenological analysis of the branching ratio, and examine the influence of resulting correlations on the like-sign dimuon charge asymmetry in B decays. |
|
|
Address |
[Jung, Martin; Pich, Antonio; Tuzon, Paula] Univ Valencia, CSIC, IFIC, Dept Fis Teor, E-46071 Valencia, Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1550-7998 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000289519400002 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
no |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
603 |
|
Permanent link to this record |
|
|
|
|
Author |
n_TOF Collaboration (Lederer, C. et al); Domingo-Pardo, C.; Tain, J.L. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title ![sorted by Title field, descending order (down)](img/sort_desc.gif) |
Au-197(n,gamma) cross section in the unresolved resonance region |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Physical Review C |
Abbreviated Journal |
Phys. Rev. C |
|
|
Volume |
83 |
Issue |
3 |
Pages |
034608 - 11pp |
|
|
Keywords |
|
|
|
Abstract |
The cross section of the reaction Au-197(n,gamma) was measured with the time-of-flight technique at the n_TOF (neutron time-of-flight) facility in the unresolved resonance region between 5 and 400 keV using a pair of C6D6 (where D denotes H-2) liquid scintillators for the detection of prompt capture gamma rays. The results with a total uncertainty of 3.9%-6.7% for a resolution of 20 bins per energy decade show fair agreement with the Evaluated Nuclear Data File Version B-VII.0 (ENDF/B-VII.0), which contains the standard evaluation. The Maxwellian-averaged cross section (MACS) at 30 keV is in excellent agreement with the one according to the ENDF/B-VII.0 evaluation and 4.7% higher than the MACS measured independently by activation technique. Structures in the cross section, which had also been reported earlier, have been interpreted as being due to clusters of resonances. |
|
|
Address |
[Colonna, N.; Barbagallo, M.; Marrone, S.; Tagliente, G.; Terlizzi, R.] Ist Nazl Fis Nucl, I-70126 Bari, Italy, Email: claudia.lederer@univie.ac.at |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0556-2813 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000288511800004 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
550 |
|
Permanent link to this record |
|
|
|
|
Author |
Soriano, A.; Gonzalez, A.; Orero, A.; Moliner, L.; Carles, M.; Sanchez, F.; Benlloch, J.M.; Correcher, C.; Carrilero, V.; Seimetz, M. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title ![sorted by Title field, descending order (down)](img/sort_desc.gif) |
Attenuation correction without transmission scan for the MAMMI breast PET |
Type |
Journal Article |
|
Year |
2011 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
648 |
Issue |
|
Pages |
S75-S78 |
|
|
Keywords |
Breast PET; Attenuation correction |
|
|
Abstract |
Whole-body Positron Emission Tomography (PET) scanners are required in order to span large Fields of View (FOV). Therefore, reaching the sensitivity and spatial resolution required for early stage breast tumor detection is not straightforward. MAMMI is a dedicated breast PET scanner with a ring geometry designed to provide PET images with a spatial resolution as high as 1.5 mm, being able to detect small breast tumors ( < 1 cm). The patient lays down in prone position during the scan, thus making possible to image the whole breast, up to regions close to the base of the pectoral without the requirement of breast compression. Attenuation correction (AC) for PET data improves the image quality and the quantitative accuracy of radioactivity distribution determination. In dedicated, high resolution breast cancer scanners, this correction would enhance the proper diagnosis in early disease stages. In whole-body PET scanners, AC is usually taken into account with the use of transmission scans, either by external radioactive rod sources or by Computed Tomography (CT). This considerably increases the radiation dose administered to the patient and time needed for the exploration. In this work we propose a method for breast shape identification by means of PET image segmentation. The breast shape identification will be used for the determination of the AC. For the case of a specific breast PET scanner the procedure we propose should provide AC similar to that obtained by transmission scans as we take advantage of the breast anatomical simplicity. Experimental validation of the proposed approach with a dedicated breast PET prototype is also presented. The main advantage of this method is an important dose reduction since the transmission scan is not required. |
|
|
Address |
[Soriano, A.; Orero, A.; Moliner, L.; Carles, M.; Sanchez, F.; Benlloch, J. M.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna, Spain, Email: soriano@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000305376900021 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
no |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1069 |
|
Permanent link to this record |