LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2016). Observation of the B (s) (0) -> J/psi phi phi decay. J. High Energy Phys., 03(3), 040–18pp.
Abstract: The B (s) (0) -> J/psi phi phi decay is observed in pp collision data corresponding to an integrated luminosity of 3 fb(-1) recorded by the LHCb detector at centre-of-mass energies of 7 TeV and 8 TeV. This is the first observation of this decay channel, with a statistical significance of 15 standard deviations. The mass of the B (s) (0) meson is measured to be 5367.08 +/- 0.38 +/- 0.15 MeV/c(2). The branching fraction ratio B[B(s)(0) -> J/psi phi phi]/B[B(s)(0) -> J/psi phi] is measured to be 0.0115 +/- 0.0012 (- 0.0009) (+ 0.0005) . In both cases, the first uncertainty is statistical and the second is systematic. No evidence for non-resonant B(s)(0) -> J/psi phi K (+) K (-) or B(s)(0) -> J/psi K (+) K (-) K (+) K (-) decays is found.
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2023). Observation of the B0s → χc1(3872)π+π- decay. J. High Energy Phys., 07(7), 084–25pp.
Abstract: The first observation of the B-s(0) -> (chi(c1)(3872) -> J/Psi pi(broken vertical bar) pi(-)) pi(broken vertical bar) pi(-) decay is reported using proton-proton collision data, corresponding to integrated luminosities of 1, 2 and 6 fb(-1), collected by the LHCb experiment at centre-of-mass energies of 7, 8 and 13TeV, respectively. The ratio of branching fractions relative to the B-s(0) -> (Psi(2S) -> J/Psi pi(+) pi(-)) pi(+) pi(-) decay is measured to be [GRAPHICS] where the first uncertainty is statistical and the second systematic. The mass spectrum of the pi(+) pi(-) system recoiling against the chi(c1)(3872) meson exhibits a large contribution from B-s(0) -> chi(c1)(3872) (integral(0)(980) -> pi(+) pi(-)) decays.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2018). Observation of the decay Lambda(0)(b) -> psi(2S)p pi(-). J. High Energy Phys., 08(8), 131–18pp.
Abstract: The Cabibbo-suppressed decay Lambda(0)(b) -> psi(2S)p pi(-) is observed for the fi rst time using a data sample collected by the LHCb experiment in proton-proton collisions corresponding to 1.0, 2.0 and 1.9 fb(-1) of integrated luminosity at centre-of-mass energies of 7, 8 and 13TeV, respectively. The psi(2S) mesons are reconstructed in the mu(+)mu(-) fi nal state. The branching fraction with respect to that of the Lambda(0)(b) -> psi(2S)pK(-) decay mode is measured to be B (Lambda(0)(b) -> psi(2S)p pi(-))/B (Lambda(0)(b) -> psi(2S)pK(-)) = (11.44 +/- 1.3 +/- 0.2)%, where the fi rst uncertainty is statistical and the second is systematic. The psi(2S) p and psi(2S)pi(-) mass spectra are investigated and no evidence for exotic resonances is found.
|
Olleros, P., Caballero, L., Domingo-Pardo, C., Babiano, V., Ladarescu, I., Calvo, D., et al. (2018). On the performance of large monolithic LaCl3(Ce) crystals coupled to pixelated silicon photosensors. J. Instrum., 13, P03014–17pp.
Abstract: We investigate the performance of large area radiation detectors, with high energy-and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development aims for an enhancement in detection sensitivity in time-of-flight neutron capture measurements, versus the commonly used C6D6 liquid scintillation total-energy detectors. In this work, we study in detail the impact of the readout photosensor on the energy response of large area (50 x 50 mm(2)) monolithic LaCl3(Ce) crystals, in particular when replacing a conventional mono-cathode photomultiplier tube by an 8 x 8 pixelated silicon photomultiplier. Using the largest commercially available monolithic SiPM array (25 cm(2)), with a pixel size of 6 x 6 mm(2), we have measured an average energy resolution of 3.92% FWHM at 662 keV for crystal thick-nesses of 10, 20 and 30 mm. The results are confronted with detailed Monte Carlo (MC) calculations, where optical processes and properties have been included for the reliable tracking of the scintillation photons. After the experimental validation of the MC model, we use our MC code to explore the impact of a smaller photosensor segmentation on the energy resolution. Our optical MC simulations predict only a marginal deterioration of the spectroscopic performance for pixels of 3 x 3 mm(2).
|
Doncel, M., Cederwall, B., Gadea, A., Gerl, J., Kojouharov, I., Martin, S., et al. (2017). Performance and imaging capabilities of the DEGAS high-resolution gamma-ray detector array for the DESPEC experiment at FAIR. Nucl. Instrum. Methods Phys. Res. A, 873, 36–38.
Abstract: Monte Carlo simulations of one of the possible configurations of the imaging phase for the DEGAS spectrometer situated at the DESPEC/NUSTAR experiment have been performed. The geometry consists of the coupling of the high-resolution gamma spectroscopy array, AGATA, with a high-resolution segmented planar detector utilized as an implantation detector in a compact configuration. The sensitivity and performance of the array in terms of efficiency and imaging capability is deduced.
|
Korichi, A., Lauritsen, T., Wilson, A. N., Dudouet, J., Clement, E., Lalovic, N., et al. (2017). Performance of a gamma-ray tracking array: Characterizing the AGATA array using a Co-60 source. Nucl. Instrum. Methods Phys. Res. A, 872, 80–86.
Abstract: The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4 pi implementation of the device.
|
Lalovic, N., Louchart, C., Michelagnoli, C., Perez-Vidal, R. M., Ralet, D., Gerl, J., et al. (2016). Performance of the AGATA gamma-ray spectrometer in the PreSPEC set-up at GSI. Nucl. Instrum. Methods Phys. Res. A, 806, 258–266.
Abstract: In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the y-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the 7 ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC-AGATA experimental campaign at the GSI Helmholtzzentrum fur Schwerionenforschung. Using the radioactive sources Co-56, Co-60 and Eu-152, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated.
|
Barrientos, D., Bellato, M., Bazzacco, D., Bortolato, D., Cocconi, P., Gadea, A., et al. (2015). Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array. IEEE Trans. Nucl. Sci., 62(6), 3134–3139.
Abstract: In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.53% at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2015). Precise measurements of the properties of the B-1(5721)(0,+) and B-2*(5747)(0,+) states and observation of B-+,B-0 pi(-,+) mass structures. J. High Energy Phys., 04(4), 024–27pp.
Abstract: Invariant mass distributions of B (+) pi (-) and B (0) pi (+) combinations are investigated in order to study excited B mesons. The analysis is based on a data sample corresponding to 3.0 fb(-1) of pp collision data, recorded by the LHCb detector at centre-of-mass energies of 7 and 8 TeV. Precise measurements of the masses and widths of the B (1)(5721)(0,+) and B (2)(5747)(0,+) states are reported. Clear enhancements, particularly prominent at high pion transverse momentum, are seen over background in the mass range 5850-6000 MeV in both B (+) pi (-) and B (0) pi (+) combinations. The structures are consistent with the presence of four excited B mesons, labelled B (J) (5840)(0,+) and B (J) (5960)(0,+), whose masses and widths are obtained under different hypotheses for their quantum numbers.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Precision measurement of the B-c(+) meson mass. J. High Energy Phys., 07(7), 123–21pp.
Abstract: A precision measurement of the B-c(+) meson mass is performed using proton- proton collision data collected with the LHCb experiment at centre-of-mass energies of 7, 8 and 13 TeV, corresponding to a total integrated luminosity of 9.0 fb(-1). The B-c(+) mesons are reconstructed via the decays B-c(+)-> J/psi pi(+), B-c(+)-> J/psi pi(+)pi(-)pi(+), B-c(+)-> J/psi pp<overbar>pi(+), B-c(+)-> J/psi D-s(+), B-c(+)-> J/psi (DK+)-K-0 and B-c(+)-> B-s(0)pi(+). Combining the results of the individual decay channels, the B-c(+) mass is measured to be 6274.47 +/- 0.27 (stat) +/- 0.17 (syst) MeV/c(2). This is the most precise measurement of the B-c(+) mass to date. The difference between the B-c(+) and B-s(0) meson masses is measured to be 907.75 +/- 0.37 (stat) +/- 0.27 (syst) MeV/c(2).
|