Jimenez, E., & Vaquera-Araujo, C. A. (2016). Lagrangians for massive Dirac chiral superfields. Nucl. Phys. B, 907, 18–36.
Abstract: A variant for the superspin one-half massive superparticle in 4D, N = 1, based on Dirac superfields, is offered. As opposed to the current known models that use spinor chiral superfields, the propagating fields of the supermultiplet are those of the lowest mass dimensions possible: scalar, Dirac and vector fields. Besides the supersymmetric chiral condition, the Dirac superfields are not further constrained, allowing a very straightforward implementation of the path-integral method. The corresponding superpropagators are presented. In addition, an interaction super Yukawa potential, formed by Dirac and scalar chiral superfields, is given in terms of their component fields. The model is first presented for the case of two superspin one-half superparticles related by the charged conjugation operator, but in order to treat the case of neutral superparticles, the Majorana condition on the Dirac superfields is also studied. We compare our proposal with the known models of spinor superfields for the one-half superparticle and show that it is equivalent to them.
|
Moline, A., Schewtschenko, J. A., Palomares-Ruiz, S., Boehm, C., & Baugh, C. M. (2016). Isotropic extragalactic flux from dark matter annihilations: lessons from interacting dark matter scenarios. J. Cosmol. Astropart. Phys., 08(8), 069–23pp.
Abstract: The extragalactic gamma-ray and neutrino emission may have a contribution from dark matter (DM) annihilations. In the case of discrepancies between observations and standard predictions, one could infer the DM pair annihilation cross section into cosmic rays by studying the shape of the energy spectrum. So far all analyses of the extragalactic DM signal have assumed the standard cosmological model (ACDM) as the underlying theory. However, there are alternative DM scenarios where the number of low-mass objects is significantly suppressed. Therefore the characteristics of the gamma-ray and neutrino emission in these models may differ from ACDM as a result. Here we show that the extragalactic isotropic signal in these alternative models has a similar energy dependence to that in ACDM, but the overall normalisation is reduced. The similarities between the energy spectra combined with the flux suppression could lead one to misinterpret possible evidence for models beyond ACDM as being due to CDM particles annihilating with a much weaker cross section than expected.
|
Gomez-Cadenas, J. J., Benlloch-Rodriguez, J. M., Ferrario, P., Monrabal, F., Rodriguez, J., & Toledo, J. F. (2016). Investigation of the coincidence resolving time performance of a PET scanner based on liquid xenon: a Monte Carlo study. J. Instrum., 11, P09011–18pp.
Abstract: The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the coincidence resolving time (CRT) of the gammas is sufficiently good. The best commercial PET-TOF system today (based in LYSO crystals and digital SiPMs), is the VEREOS of Philips, boasting a CRT of 316 ps (FWHM). In this paper we present a Monte Carlo investigation of the CRT performance of a PET scanner exploiting the scintillating properties of liquid xenon. We find that an excellent CRT of 70 ps (depending on the PDE of the sensor) can be obtained if the scanner is instrumented with silicon photomultipliers (SiPMs) sensitive to the ultraviolet light emitted by xenon. Alternatively, a CRT of 160 ps can be obtained instrumenting the scanner with (much cheaper) blue-sensitive SiPMs coated with a suitable wavelength shifter. These results show the excellent time of flight capabilities of a PET device based in liquid xenon.
|
Fuentes-Martin, J., Portoles, J., & Ruiz-Femenia, P. (2016). Integrating out heavy particles with functional methods: a simplified framework. J. High Energy Phys., 09(9), 156–26pp.
Abstract: We present a systematic procedure to obtain the one-loop low-energy effective Lagrangian resulting from integrating out the heavy fields of a given ultraviolet theory. We show that the matching coefficients are determined entirely by the hard region of the functional determinant involving the heavy fields. This represents an important simplification with respect the conventional matching approach, where the full and effective theory contributions have to be computed separately and a cancellation of the infrared divergent parts has to take place. We illustrate the method with a descriptive toy model and with an extension of the Standard Model with a heavy real scalar triplet. A comparison with other schemes that have been put forward recently is also provided.
|
Andricek, L., Boronat, M., Fuster, J., Garcia, I., Gomis, P., Marinas, C., et al. (2016). Integrated cooling channels in position-sensitive silicon detectors. J. Instrum., 11, P06018–15pp.
Abstract: We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10 W/cm(2). The liquid flow is found to have a negligible impact on the mechanical stability. A finite-element simulation predicts the cooling performance to an accuracy of approximately 10%.
|