toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Moreno, O.; Sarriguren, P.; Algora, A.; Fraile, L.M.; Orrigo, S.E.A. doi  openurl
  Title (up) Bulk and decay properties of neutron-deficient odd-mass Hg isotopes near A=185 Type Journal Article
  Year 2022 Publication Physical Review C Abbreviated Journal Phys. Rev. C  
  Volume 106 Issue 3 Pages 034317 - 11pp  
  Keywords  
  Abstract Ground and isomeric states of the neutron-deficient odd-A isotopes 183Hg, 185Hg, and 187Hg are described from a microscopic calculation based on a self-consistent, axially deformed Hartree-Fock mean field with the Skyrme functional and pairing within BCS approximation. For each equilibrium shape and different odd-neutron states, results on mean-square charge radii and magnetic dipole moments are given and analyzed in the context of their sensitivity to the nuclear deformation and to the spin and parity. Spin-isospin correlations within proton-neutron quasiparticle random phase approximation are then introduced in the nuclear states to obtain the distributions of Gamow-Teller strength and the beta+/EC half-lives of these isotopes, whose measurements are planned at ISOLDE-CERN using total absorption gamma-ray spectroscopy techniques.  
  Address [Moreno, O.; Fraile, L. M.] Univ Complutense Madrid, Dept Estruct Mat Fis Term & Elect, Grp Fis Nucl, Av Complutense s-n, E-28040 Madrid, Spain, Email: osmoreno@ucm.es  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2469-9985 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000861758100001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5368  
Permanent link to this record
 

 
Author Moreira, A.R.P.; Belchior, F.M.; Maluf, R.V.; Almeida, C.A.S. doi  openurl
  Title (up) Bulk fields localization on thick string-like brane in f(T) gravity Type Journal Article
  Year 2023 Publication European Physical Journal Plus Abbreviated Journal Eur. Phys. J. Plus  
  Volume 138 Issue 8 Pages 730 - 15pp  
  Keywords  
  Abstract This paper aims to investigate the influence of torsion on bulk fields in the codimension two thick brane in f(T) modified teleparallel gravity. It is shown that the brane supports the localization of gauge field zero mode without an extra coupling. However, Kalb-Ramond and fermionic fields require a suitable coupling. Then, it is proposed a geometrical coupling based on results in 5D thick brane in modified teleparallel gravities. The Kalb-Ramond field is coupled to torsion scalar T through a gauge-invariant interaction. For the case of fermionic fields, we study the Dirac fermions and gravitino with a derivative geometrical coupling. For all of the fields, it obtained massive and resonant modes by employing the Schodinger-like approach.  
  Address [Moreira, A. R. P.; Belchior, F. M.; Maluf, R. V.; Almeida, C. A. S.] Univ Fed Ceara UFC, Dept Fis, CP 6030,Campus Pici, BR-60455760 Fortaleza, CE, Brazil, Email: carlos@fisica.ufc.br  
  Corporate Author Thesis  
  Publisher Springer Heidelberg Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2190-5444 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001052796100002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5621  
Permanent link to this record
 

 
Author Belen Galan, M.; Alvarez-Ruso, L.; Rafi Alam, M.; Ruiz Simo, I.; Vicente Vacas, M.J. url  doi
openurl 
  Title (up) Cabibbo suppressed hyperon production off nuclei induced by antineutrinos Type Journal Article
  Year 2024 Publication Physical Review D Abbreviated Journal Phys. Rev. D  
  Volume 109 Issue 3 Pages 033001 - 13pp  
  Keywords  
  Abstract In this work, we study the production of E and A hyperons in strangeness -changing AS = -1 chargedcurrent interactions of muon antineutrinos on nuclear targets. At the nucleon level, besides quasielastic scattering, we consider the inelastic mechanism in which a pion is produced alongside the hyperon. Its relevance for antineutrinos with energies below 2 GeV is conveyed in integrated and differential cross sections. We observe that the distributions on the angle between the hyperon and the final lepton are clearly different for quasielastic and inelastic processes. Hyperon final -state interactions, modeled with an intranuclear cascade, lead to a significant transfer from primary produced E's into final A's. They also cause considerable energy loss, which is apparent in hyperon energy distributions. We have investigated A production off 40Ar in the conditions of the recently reported MicroBooNE measurement. We find that the A pi contribution, dominated by E*(1385) excitation, accounts for about one third of the cross section.  
  Address [Galan, M. Benitez; Simo, I. Ruiz] Univ Granada, Fac Ciencias, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain, Email: mbenitezgalan@ugr.es;  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2470-0010 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001179626500005 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 6066  
Permanent link to this record
 

 
Author Bazzocchi, F.; Cerdeño, D.G.; Muñoz, C.; Valle, J.W.F. url  doi
openurl 
  Title (up) Calculable inverse-seesaw neutrino masses in supersymmetry Type Journal Article
  Year 2010 Publication Physical Review D Abbreviated Journal Phys. Rev. D  
  Volume 81 Issue 5 Pages 051701 - 5pp  
  Keywords  
  Abstract We provide a scenario where naturally small and calculable neutrino masses arise from a supersymmetry-breaking renormalization-group-induced vacuum expectation value. The construction consists of an extended version of the next-to-minimal supersymmetric standard model and the mechanism is illustrated for a universal choice of the soft supersymmetry-breaking parameters. The lightest supersymmetric particle can be an isosinglet scalar neutrino state, potentially viable as WIMP dark matter through its Higgs new boson coupling. The scenario leads to a plethora of new phenomenological implications at accelerators including the Large Hadron Collider.  
  Address [Bazzocchi, F.] Vrije Univ Amsterdam, Dept Phys & Astron, NL-1081 HV Amsterdam, Netherlands, Email: fbazzoc@few.vu.nl  
  Corporate Author Thesis  
  Publisher Amer Physical Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1550-7998 ISBN Medium  
  Area Expedition Conference  
  Notes ISI:000276194200005 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ elepoucu @ Serial 471  
Permanent link to this record
 

 
Author Romero-Barrientos, J.; Marquez Damian, J.I.; Molina, F.; Zambra, M.; Aguilera, P.; Lopez-Usquiano, F.; Parra, B.; Ruiz, A. url  doi
openurl 
  Title (up) Calculation of kinetic parameters beta eff and L with modified open source Monte Carlo code OpenMC(TD) Type Journal Article
  Year 2022 Publication Nuclear Engineering and Technology Abbreviated Journal Nucl. Eng. Technol.  
  Volume 54 Issue 3 Pages 811-816  
  Keywords OpenMC; Monte Carlo; Kinetic parameters; Open source; Neutron generation time; Effective delayed neutron fraction  
  Abstract This work presents the methodology used to expand the capabilities of the Monte Carlo code OpenMC for the calculation of reactor kinetic parameters: effective delayed neutron fraction beff and neutron generation time L. The modified code, OpenMC(Time-Dependent) or OpenMC(TD), was then used to calculate the effective delayed neutron fraction by using the prompt method, while the neutron generation time was estimated using the pulsed method, fitting L to the decay of the neutron population. OpenMC(TD) is intended to serve as an alternative for the estimation of kinetic parameters when licensed codes are not available. The results obtained are compared to experimental data and MCNP calculated values for 18 benchmark configurations.  
  Address [Romero-Barrientos, J.; Molina, F.; Zambra, M.; Aguilera, P.; Lopez-Usquiano, F.; Ruiz, A.] Comis Chilena Energia Nucl, Santiago 12501, Chile, Email: romeroj@uchile.cl  
  Corporate Author Thesis  
  Publisher Korean Nuclear Soc Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1738-5733 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000766649800004 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5172  
Permanent link to this record
 

 
Author de Salas, P.F.; Gariazzo, S.; Lesgourgues, J.; Pastor, S. url  doi
openurl 
  Title (up) Calculation of the local density of relic neutrinos Type Journal Article
  Year 2017 Publication Journal of Cosmology and Astroparticle Physics Abbreviated Journal J. Cosmol. Astropart. Phys.  
  Volume 09 Issue 9 Pages 034 - 24pp  
  Keywords cosmological neutrinos; dark matter simulations; galaxy clustering; neutrino experiments  
  Abstract Nonzero neutrino masses are required by the existence of flavour oscillations, with values of the order of at least 50 meV. We consider the gravitational clustering of relic neutrinos within the Milky Way, and used the N – one-body simulation technique to compute their density enhancement factor in the neighbourhood of the Earth with respect to the average cosmic density. Compared to previous similar studies, we pushed the simulation down to smaller neutrino masses, and included an improved treatment of the baryonic and dark matter distributions in the Milky Way. Our results are important for future experiments aiming at detecting the cosmic neutrino background, such as the Princeton Tritium Observatory for Light, Early-universe, Massive-neutrino Yield (PTOLEMY) proposal. We calculate the impact of neutrino clustering in the Milky Way on the expected event rate for a PTOLEMY-like experiment. We find that the effect of clustering remains negligible for the minimal normal hierarchy scenario, while it enhances the event rate by 10 to 20% (resp. a factor 1.7 to 2.5) for the minimal inverted hierarchy scenario (resp. a degenerate scenario with 150 meV masses). Finally we compute the impact on the event rate of a possible fourth sterile neutrino with a mass of 1.3 eV.  
  Address [de Salas, P. F.; Gariazzo, S.; Pastor, S.] Univ Valencia, CSIC, Inst Fis Corpuscular, Parc Cient UV,C Catedrat Jose Beltran 2, E-46980 Paterna, Valencia, Spain, Email: pabferde@ific.uv.es;  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1475-7516 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000411617000002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3308  
Permanent link to this record
 

 
Author Viñals, S.; Nacher, E.; Tengblad, O.; Borge, M.J.G.; Briz, J.A.; Gad, A.; Munch, M.; Perea, A. doi  openurl
  Title (up) Calibration and response function of a compact silicon-detector set-up for charged-particle spectroscopy using GEANT4 Type Journal Article
  Year 2021 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 57 Issue 2 Pages 49 - 9pp  
  Keywords  
  Abstract A complete methodology for detector calibration and energy-loss correction in charged-particle spectroscopy is presented. This has been applied to a compact set-up of four silicon detectors used for beta-delayed particle spectroscopy. The characterisation of the set-up was carried out using GEANT4 Monte Carlo simulations and standard alpha-calibration sources. The response function of the system was in this way accurately determined to be used for spectral unfolding.  
  Address [Vinals, S.; Tengblad, O.; Borge, M. J. G.; Briz, J. A.; Perea, A.] CSIC, Inst Estruct Mat, E-28006 Madrid, Spain, Email: enrique.nacher@csic.es;  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000615748600001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4710  
Permanent link to this record
 

 
Author Quintero-Quintero, A.; Patiño-Camargo, G.; Soriano, A.; Palma, J.D.; Vilar-Palop, J.; Pujades, M.C.; Llorca-Domaica, N.; Ballester, F.; Vijande, J.; Candela-Juan, C. doi  openurl
  Title (up) Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures Type Journal Article
  Year 2018 Publication Journal of Radiological Protection Abbreviated Journal J. Radiol. Prot.  
  Volume 38 Issue 2 Pages 549-563  
  Keywords backscatter correction factor; TLD; lead apron; fluoroscopy; eye lens dose  
  Abstract Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of the Monte Carlo (MC) code Penelope. The results obtained were validated against measurements performed in reference conditions in a secondary standard dosimetry laboratory. Next, the MC model was used to evaluate the backscatter correction factor needed for the case where the dosimeter is worn over a lead shield to estimate the personal equivalent dose H-p(0.07) to unprotected soft tissues. For this purpose, the TLD was irradiated over a water slab phantom with a photon beam representative of the result of a fluoroscopy beam scattered by a patient. Incident beam angles of 0 degrees and 60 degrees, and lead thicknesses between the TLD and phantom of 0.25 and 0.5 mm Pb were considered. A backscatter correction factor of 1.23 (independent of lead thickness) was calculated comparing the results with those faced in reference conditions (i.e., without lead shield and with an angular incidence of 0 degrees). The corrected dose algorithm was validated in laboratory conditions with dosi-meters irradiated over a thyroid collar and angular incidences of 0 degrees, 40 degrees and 60 degrees, as well as with dosimeters worn by interventional radiologists and cardiologists. The corrected dose algorithm provides a better approach to estimate the equivalent dose to unprotected soft tissues such as eye lenses. Dosimeters that are not shielded from backscatter radiation might underestimate personal equivalent doses when worn over a lead apron and, therefore, should be specifically characterized for this purpose.  
  Address [Quintero-Quintero, A.; Patino-Camargo, G.] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Valencia, Spain, Email: ccanjuan@gmail.com  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0952-4746 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000428913900001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3552  
Permanent link to this record
 

 
Author ATLAS Collaboration (Aad, G. et al); Amos, K.R.; Aparisi Pozo, J.A.; Bailey, A.J.; Bouchhar, N.; Cabrera Urban, S.; Cantero, J.; Cardillo, F.; Castillo Gimenez, V.; Chitishvili, M.; Costa, M.J.; Didenko,, M.; Escobar, C.; Fiorini, L.; Fullana Torregrosa, E.; Fuster, J.; Garcia, C.; Garcia Navarro, J.E.; Gomez Delegido, A.J.; Gonzalez de la Hoz, S.; Gonzalvo Rodriguez, G.R.; Guerrero Rojas, J.G.R.; Higon-Rodriguez, E.; Lacasta, C.; Lozano Bahilo, J.J.; Marti-Garcia, S.; Martinez Agullo, P.; Miralles Lopez, M.; Mitsou, V.A.; Monsonis Romero, L.; Moreno Llacer, M.; Munoz Perez, D.; Navarro-Gonzalez, J.; Poveda, J.; Prades Ibañez, A.; Rubio Jimenez, A.; Ruiz-Martinez, A.; Sabatini, P.; Salt, J.; Sanchez Sebastian, V.; Sayago Galvan, I.; Senthilkumar, V.; Soldevila, U.; Sanchez, J.; Torro Pastor, E.; Valero, A.; Valls Ferrer, J.A.; Varriale, L.; Villaplana Perez, M.; Vos, M. url  doi
openurl 
  Title (up) Calibration of the light-flavour jet mistagging efficiency of the b-tagging algorithms with Z plus jets events using 139 fb<SUP>-1</SUP> of ATLAS proton-proton collision data at √s=13 TeV Type Journal Article
  Year 2023 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C  
  Volume 83 Issue 8 Pages 728 - 30pp  
  Keywords  
  Abstract The identification of b-jets, referred to as b-tagging, is an important part of many physics analyses in the ATLAS experiment at the Large Hadron Collider and an accurate calibration of its performance is essential for high-quality physics results. This publication describes the calibration of the light-flavour jet mistagging efficiency in a data sample of proton-proton collision events at root s = 13 TeV corresponding to an integrated luminosity of 139 fb(-1). The calibration is performed in a sample of Z bosons produced in association with jets. Due to the low mistagging efficiency for light-flavour jets, a method which uses modified versions of the b-tagging algorithms referred to as flip taggers is used in this work. A fit to the jet-flavour-sensitive secondary-vertex mass is performed to extract a scale factor from data, to correct the light-flavour jet mistagging efficiency in Monte Carlo simulations, while simultaneously correcting the b-jet efficiency. With this procedure, uncertainties coming from the modeling of jets from heavy-flavour hadrons are considerably lower than in previous calibrations of the mistagging scale factors, where they were dominant. The scale factors obtained in this calibration are consistent with unity within uncertainties.  
  Address [Filmer, E. K.; Jackson, P.; Kong, A. X. Y.; Potti, H.; Ruggeri, T. A.; Ting, E. X. L.; White, M. J.] Univ Adelaide, Dept Phys, Adelaide, SA, Australia  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6044 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001062397300002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5782  
Permanent link to this record
 

 
Author NEXT Collaboration (Martinez-Lema, G. et al); Palmeiro, B.; Botas, A.; Laing, A.; Renner, J.; Simon, A.; Alvarez, V.; Benlloch-Rodriguez, J.M.; Carcel, S.; Carrion, J.V.; Diaz, J.; Felkai, R.; Kekic, M.; Lopez-March, N.; Martinez, A.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Perez, J.; Querol, M.; Rodriguez, J.; Romo-Lugue, C.; Sorel, M.; Torrent, J.; Yahlali, N. url  doi
openurl 
  Title (up) Calibration of the NEXT-White detector using Kr-83m decays Type Journal Article
  Year 2018 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.  
  Volume 13 Issue Pages P10014 - 21pp  
  Keywords Charge transport; multiplication and electroluminescence in rare gases and liquids; Gaseous imaging and tracking detectors; Time projection Chambers (TPC); Double-beta decay detectors  
  Abstract The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using Kr-83m decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) +/- 0.324 (sys.)) % FWHM in the full chamber and (3.804 +/- 0.013 (stat.) +/- 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/root E scaling, these values translate into resolutions of (0.5916 +/- 0.0014 (stat.) +/- 0.0421 (sys.)) % FWHM and (0.4943 +/- 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Q(beta beta) energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.  
  Address [Hauptman, J.] Iowa State Univ, Dept Phys & Astron, 12 Phys Hall, Ames, IA 50011 USA, Email: gonzalo.martinez.lema@usc.es  
  Corporate Author Thesis  
  Publisher Iop Publishing Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1748-0221 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000447061800001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3754  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva